Loading...
HomeMy WebLinkAboutEngineered Plan - 2015TOP FOUND. EL. 32.0' PRECAST H-10 RISERS (TYP.) 2'a *29.4 _.. *28.7 28.25' PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE SYSTEM PROFILE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. (NOT TO SCALE) j MINIMUM .75'10F COVER OVER PRECAST 1 NOTE: 2" MIN. WALL THICKNESS REQUIRED 4"OSCH40 PVC PIPES LEVEL 1ST 2' 10" 1500 GAL H-10 14." ' TEE SEPTIC TANK TEE 8.00' " 000000000000 WATERTEST D'BOX GAS BAFFLE.., �°OCOw0O°O°°° FOR LEVELNESS 4' LIQ. LEVEL (ACME OR EQUAL) J. 27.20' 27.03' .^0 0 0 0 0 0 0 0 0 0 0 0 0 Off•{. ;0;0;0;0;0;0; 0 0 0 0 0 0 0 0 0 0 0 0 0 0 °°O°O°O°O°O°O°0°O°O°O°O°O°O°O°O°O°O°O°0009 ,,o„o_n_0_n��_1 0 o O o n c_n_n_n_n_n.o 0 I 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) (4.5% SLOPE) ( 8 % SLOPE) (-1-7. SLOPE) FOUNDATION- 10' SEPTIC TANK 9' D' BOX 5' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- EGEND99- 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]----- PROPOSED CONTOUR C.O. PROPOSED CLEAN OUT TH1 69 EXISTING TEST HOLE 2� SLOPE OF GROUND TOP FNDN. _ UTILITY POLE EL. 32.0' FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 7/28/15 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 p" 4 30.0' 16" FILL ww-1 36" 1OYR 5/8 27.0' C1 PERC MS ®48" 1OYR 5/8 96" 0) n' C2 LS 110" 2.5Y 5/4 20.8' C3 MS 138" 2.5Y 7/3 18.5' NO GROUNDWATER ENCOUNTERED 30.25 Z 91 i I I 9 c I �c I Q I I �S I 4W �W ' O JO I � LOT 7 Q / 12,650± SF V 31.49 / 8 1 PAVED DRIVE 1.74 32.00 / I / .64 2.06 Y r PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE 2% SLOPE REQUIRED OVER SYSTEM 30.0' 27.4' 27.0' 0.92' 26.08' OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 25' X 11.3' (NO STONE PROPDSED) EACH UNIT = 6.25' x 2183' x 1.33' HIGH 4.1 7.6' 16 INFILTRATOR HIGH C PACITY UNITS LEACHING 22.0' BOTTOM C1 LAYER FACILITY j 18.5' BOTTOM TH-1 I NO GROUNDWATER FOUND I 4 I 11000, .86 PROP. CLEAN OUT �c �xG 1.19 i cN1.05 �I TH .31 i NOTE: 2 / / g / ECK 31.49 10 1.26 31.23 .03 � 30. lid.--O--o 30.70 NOTES 1. DATUM IS APPROX. NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-jQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. INVERTS •51 OUT OF 313845 DWELL. 31.58 %e de,• 31.48 69 EXISTING DWELLING S TOP FNDN. _ 0 EL. 32.0' / / g / ECK 31.49 10 1.26 31.23 .03 � 30. lid.--O--o 30.70 NOTES 1. DATUM IS APPROX. NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-jQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. LOCUS MAP NOT TO SCALE ASSESSORS MAP 132 PARCEL 34 VARIANCE REQUESTED UNDER MAX. FEASIBLE COMPLIANCE 15.405 1b: SAS TO BE 15' OFF FOUNDATION (5' VARIANCE REQUIRED) SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW BENCH MARK - TOP OF SEPTIC TANK: 330 GPD (2) = 660 CONC. BOUND. ELEV = 29.0' USE A 1500 GAL. H-10 SEPTIC TANK LEACHING: �KADZ FENCE 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER �o .38 HIGH CAPACITY INFILTRATOR UNIT 77 8.95 330 GPD/0.74 GPD/SF = 445.9 SF LEACHING REQ'D 445.9 SF/29.56 SF/UNIT = 15.1 UNITS 12" AK 1j 28.83 V 0 30 � W %e de,• 0 V Mo t S 0 64 CR 28.86 29.0 Tho e e Rood o Rte 6A 29.00 x 2 .87 29.58 ____ 30- c � C 0 �JQ Sand j O LOCUS MAP NOT TO SCALE ASSESSORS MAP 132 PARCEL 34 VARIANCE REQUESTED UNDER MAX. FEASIBLE COMPLIANCE 15.405 1b: SAS TO BE 15' OFF FOUNDATION (5' VARIANCE REQUIRED) SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW BENCH MARK - TOP OF SEPTIC TANK: 330 GPD (2) = 660 CONC. BOUND. ELEV = 29.0' USE A 1500 GAL. H-10 SEPTIC TANK LEACHING: �KADZ FENCE 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER �o .38 HIGH CAPACITY INFILTRATOR UNIT 77 8.95 330 GPD/0.74 GPD/SF = 445.9 SF LEACHING REQ'D 445.9 SF/29.56 SF/UNIT = 15.1 UNITS 12" AK 1j 28.83 30.65 THEREFORE, USE GRAVELLESS SYSTEM OF (16) Permit valid for REPAIR OF' SEPTIG SYSTEM H-20 HIGH CAPACITY UNITS IN FIELD ONLY; due to. State and Local septic vary iwices. CONFIGURATION OF 4 ROWS OF 4 UNITS Board. of l'i'ealtlt review and aiwr",al is reyurred for any future additions/reno%:+iiun, alteratjuns to 16 UNITS x 29.5 SF = 472 SF > 445.9 SF sewage facilities and/or structuresid„elling' 472 SF (0.74) = 349 GPD (OK) Yarmouth Health I)cpartment A?PROV E li,5i ,Y��4 Name Date MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 18 WILD HUNTER ROAD YARMOUTH PORT IHOF,ttilssgcy HOFMAss9 PREPARED FOR DANIELA. ��o DANIEL `y�CAPE COD SEPTIC SERVICES o OJALA �`+ U A. a " CIVIL � OJALA No. 46502 No. 40980 JULY 30, 2015 16, Po�SS NAI NG\/q osss` � off 508-362-4541 sURVE fax 508-362-9880 downcape.com 100WO cave enbeiaeerin , MC. civil engineers Scale: 1"= 20' r land surveyors 939 Main Street ( Rte 6A) ! 0 10 20 30 40 50 FEET DATE DANIEL A. OJALA, P. E., P.L.S.7 YARMOUTHPORT MA 02675 1 V 0 30 � W 20' OA 0 8.67 Mo t O 0 64 CR 28.86 29.0 O Q 29.20 29.00 x 2 .87 29.58 ____ 30- 30.65 THEREFORE, USE GRAVELLESS SYSTEM OF (16) Permit valid for REPAIR OF' SEPTIG SYSTEM H-20 HIGH CAPACITY UNITS IN FIELD ONLY; due to. State and Local septic vary iwices. CONFIGURATION OF 4 ROWS OF 4 UNITS Board. of l'i'ealtlt review and aiwr",al is reyurred for any future additions/reno%:+iiun, alteratjuns to 16 UNITS x 29.5 SF = 472 SF > 445.9 SF sewage facilities and/or structuresid„elling' 472 SF (0.74) = 349 GPD (OK) Yarmouth Health I)cpartment A?PROV E li,5i ,Y��4 Name Date MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 18 WILD HUNTER ROAD YARMOUTH PORT IHOF,ttilssgcy HOFMAss9 PREPARED FOR DANIELA. ��o DANIEL `y�CAPE COD SEPTIC SERVICES o OJALA �`+ U A. a " CIVIL � OJALA No. 46502 No. 40980 JULY 30, 2015 16, Po�SS NAI NG\/q osss` � off 508-362-4541 sURVE fax 508-362-9880 downcape.com 100WO cave enbeiaeerin , MC. civil engineers Scale: 1"= 20' r land surveyors 939 Main Street ( Rte 6A) ! 0 10 20 30 40 50 FEET DATE DANIEL A. OJALA, P. E., P.L.S.7 YARMOUTHPORT MA 02675 1