HomeMy WebLinkAboutEngineered Plan - 20154
EXISTING ENDS
➢o�o�o�o� ....: .
TEE SEPTIC TANK** TEE
64.4f'* ° o 0 0 ° 6" MIN. SUMP
GAS BAFFLEo___000 Oo
°°„° °- 12" MIN. INT. DIM.
°. '•� o°000000
' >°oo°° ��.: • 4' LIQ. LEVEL (ACME OR EQUAL) . 62.27' 62.1WATERTEST D'BOX
FOR LEVELNESS H-10 500 GAL.
3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN.
ALL AROUND PRECAST STRUCTURES
6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.50' X 12.83'
COMPACTION. (15.221 [2])
8
( % SLOPE) (-L% % SLOPE)
FOUNDATION- EXIST. SEPTIC TANK 27' D' BOX 12' LEA LHIIN�GFAC
*THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT
UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE
PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE
CONDITIONS IF NOT SUITABLE
LEGEND-
-
99-
EXISTING CONTOUR
X 99 1
EXIST. SPOT ELEV.
-[99]-
SYSTEM
PROFILE
ALL OMPONENTS SHALL
TH1
P
MARKED WITHCMAGNETIC TAPE RBE
2�
(NOT TO
SCALE)
COMPARABLE MEANS FOR FUTURE LOCATION.
t
�cy,
ACCESS COVERS TO WITHIN 6" OF FIN. GRADE
2" PEASTONE OR GEOTEXTILE
CONCRETE C VERS TO WITHIN 3" GRADE
\ TOP FOUND. EL. 69.32' 1
0
FILTER FABRIC OVER STONE
•�0
cc
MINIMUM .75' OF COVER OVER PRECAST
z
2% SLOPE REQUIRED OVER SYSTEM
Mill
Follins
;• PRECAST H-10
NOTE: MIN. WALL THICKNESS 2"
( BLOCKS OR
RISERS (TYP.)
2'0
k:
,
65.8 4"0SCH40 PVC
PIPES LEVEL 1ST
2'
j PRECAST RISERS
MORTAR +ALL
COMPONF'\ITc INVERT IN 62.0'
4
EXISTING ENDS
➢o�o�o�o� ....: .
TEE SEPTIC TANK** TEE
64.4f'* ° o 0 0 ° 6" MIN. SUMP
GAS BAFFLEo___000 Oo
°°„° °- 12" MIN. INT. DIM.
°. '•� o°000000
' >°oo°° ��.: • 4' LIQ. LEVEL (ACME OR EQUAL) . 62.27' 62.1WATERTEST D'BOX
FOR LEVELNESS H-10 500 GAL.
3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN.
ALL AROUND PRECAST STRUCTURES
6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.50' X 12.83'
COMPACTION. (15.221 [2])
8
( % SLOPE) (-L% % SLOPE)
FOUNDATION- EXIST. SEPTIC TANK 27' D' BOX 12' LEA LHIIN�GFAC
*THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT
UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE
PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE
CONDITIONS IF NOT SUITABLE
LEGEND-
-
99-
EXISTING CONTOUR
X 99 1
EXIST. SPOT ELEV.
-[99]-
PROPOSED CONTOUR
198.41
PROPOSED SPOT EL.
TH1
P
TEST HOLE
2�
SLOPE OF GROUND
UTILITY POLE
�cy,
FIRE HYDRANT
NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING
TEST HOLE LOGS
ENGINEER: DANIEL E. GONSALVES, SE #13587
WITNESS: AMY VON HONE, RS
DATE: 7/28/15
PERC. RATE _ < 10 MIN/INCH
CLASS II SOILS
ELEV.
1
p" 66.0'
FILL
12"
B
LS
4819 1OYR 6/8 62.0'
C,
PERC SL
1OYR 5/6
68" 60.3'
C2
M/CS
2.5Y 7/4
126" 155.5'
NO GROUNDWATER ENCOUNTERED
LICE #15-190
x 66.
X 67
N1� 0
X 66.24 X 2
CONC BBQ PIT x 67.37
6.54 0-`
.94 E
6.14
65.77
65.53
1�0 TH
® 0 66.59
BENCH MARK - CORNER OF
CONCRETE PATIO ELEV. = 67.3
Scale:1 "= 20'
0 10 20 30 40 50 FEET
c�
\ 7�o
\ S
.83 �.
SIDES 162.83'
opo°00000°o° °°°°
°0°p°
O°0
0000000
o0�o000
00
0 0000
60.0'
NG CHAMBERS BY ACME PRECAST OR
(3) UNITS REQUIRED
55.5' BOTTOM TH-1
NO GROUNDWATER FOUND
65.47
6 \
.4 \66.77
x 6 14i \ ��
I \
67.54
( x17:78 O
67.65 68. {� / S Off%
lb
8.06
i
F k 67.95
8., 17 �
24V,
.29 EXISTING .�/ \�67 92
DWELLING
TOP OF FNDNj 3�� o A
EL. 69.32 ^/08 4 \\
404
.3
\ 67.25
Vt_7.15
CONC. PATIO
LOT 9
16,978± SF
32
i
E8.13
I
P PJj69.06
NOTES
1. DATUM IS ASSUMED
2. MUNICIPAL WATER IS EXISTING
3. MINIMUM PIPE PITCH TO BE:1/8" PER FOOT.
4. DESIGN LOADING FOR ALL PROPOSED PRECAST
UNITS TO BE AASHO H-10
5. PIPE JOINTS TO BE MADE WATERTIGHT. -
6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE
WITH 310 CMR 15.000 (TITLE 5.)
7. THIS PLAN IS FOR PROPOSED WORK ONLY AND
NOT TO BE USED FOR LOT LINE STAKING OR ANY
OTHER PURPOSE.
8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC.
9. COMPONENTS NOT TO BE BACKFILLED OR
CONCEALED WITHOUT INSPECTION BY BOARD OF
HEALTH AND PERMISSION OBTAINED FROM BOARD
OF HEALTH.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR
CALLING DIGSAFE (1-888-344-7233) AND
VERIFYING THE LOCATION OF ALL UNDERGROUND &
OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF
WORK.
11. ANY UNSUITABLE MATERIAL -ENCOUNTERED
SHALL BE REMOVED 5' BENEATH AND AROUND THE
PROPOSED LEACHING FACILITY.
12. EXISTING LEACHING FACILITY SHALL BE PUMPED
AND REMOVED OR PUMPED AND FILLED WITH CLEAN
SAND.
\E 67.65
67.28
DATE
I
LOCUS MAP
NOT TO SCALE
ASSESSORS MAP 143 PARCEL 148
SYSTEM DESIGN:
GARBAGE DISPOSER IS NOT ALLOWED
EXISTING 3 BEDROOM DWELLING
DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD
USE A 330 GPD DESIGN FLOW
SEPTIC TANK: 330 GPD (2) = 660
**RE -USE EXISTING 1000 GAL. SEPTIC TANK
LEACHING:
SIDES: 2 (33.5 + 12.83) 2 (.6) = 111 GPD
BOTTOM 33.5 x 12.83 (.6) = 258 GPD
TOTAL: 615 S. F. 369 GPD
USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL)
WITH 4' STONE ALL AROUND
V&Ir> oath Hm th Department
P 1, VED _
Llzz_S
1 *Iwiotl:i�..' Dzte
APPROVED DATE BOARD OF HEALTH MA
TITLE 5 SITE PLAN
OF
11 APACHE DRIVE
YARMOUTH PORT, MA
PREPARED FOR
B&B EXCAVATION/HERVARTH
a
DATE: AUGUST 3, 2015
Off 508-362-4541
I fax 508-362-9880
downeope.com @
dOW4 cafe engineering, inc.
civil engineers
/and surveyors
939 Main Street ( Rte 6A)
YARM UTHPORT MA 02675
0
Low
P
[Pond
�a
setucket fo
oo,
Locus
0
•�0
cc
z
Mill
Follins
P
Pond
LOCUS MAP
NOT TO SCALE
ASSESSORS MAP 143 PARCEL 148
SYSTEM DESIGN:
GARBAGE DISPOSER IS NOT ALLOWED
EXISTING 3 BEDROOM DWELLING
DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD
USE A 330 GPD DESIGN FLOW
SEPTIC TANK: 330 GPD (2) = 660
**RE -USE EXISTING 1000 GAL. SEPTIC TANK
LEACHING:
SIDES: 2 (33.5 + 12.83) 2 (.6) = 111 GPD
BOTTOM 33.5 x 12.83 (.6) = 258 GPD
TOTAL: 615 S. F. 369 GPD
USE (3) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL)
WITH 4' STONE ALL AROUND
V&Ir> oath Hm th Department
P 1, VED _
Llzz_S
1 *Iwiotl:i�..' Dzte
APPROVED DATE BOARD OF HEALTH MA
TITLE 5 SITE PLAN
OF
11 APACHE DRIVE
YARMOUTH PORT, MA
PREPARED FOR
B&B EXCAVATION/HERVARTH
a
DATE: AUGUST 3, 2015
Off 508-362-4541
I fax 508-362-9880
downeope.com @
dOW4 cafe engineering, inc.
civil engineers
/and surveyors
939 Main Street ( Rte 6A)
YARM UTHPORT MA 02675