Loading...
HomeMy WebLinkAboutEngineered Plan - 2015KEY: CONTOUR: PROPOSED CONOTOUR: • -•• QEF'' EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 GAP TEST HOLE: * 0�1 UTILITY POLE: -o-- 3����\ FENCE LINE: - ,� HYDRANT: --6- 2 N RETAINING WALL: 41 LOCATION MAP LOT 51 (8,800 SF) ASSESSORS MAP: 58 PARCEL: 348 LAND COURT CASE: 30561 B M15-28 i 105 She Daae 6 102 / SEPTIC SYSTEM DESIGN FLOW ESTIMATE: (3 BEDROOM MINIMUM DESIGN FLOW) 2 BEDROOMS AT 110 GAL / DAY = 220 GAL / DAY I SEPTIC TANK: ' 220 GAL / DAY x 2 DAYS = 440 GAL i USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) =_112 GAL/DAY BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) =_g37 GAUDAI CAPACITY = 349 GAUDAY BENCHMARK AT NAIL IN OAK TREE ELEVATION = 106.79 m SEPTIC SYSTEM SECTION ELEV. DECK COVERS WITHIN 6" OF FINISHED GRAD FOUNDATION ELEV. t1, p � 1500 GAL SEPTIC TANK ((6" OF STONE UNDER OR MECHANICALLY COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN sh — BED BATH BED ROOM ROOM PORCH KITCHEN I LIVING ROOM G FLOOR PLAN YamoutL RCLIQ Dep211"Lacat Date T MAX. (VER 1'M N) LEV. ELEV. D -BOX (6" STONE UNDER) -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, RE WITNESS: AMY VON HONE, R.S. DATE: 6-11-15 PERCOLATION RATE: < 2 MIN/IN NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 2" PEASTONE OR FILTER FABRIC - 3/4" - 1 1/2" WASHED STONE INSPECTION PORT I ELEV.= 103.03 H 100,2 4 4 ELEV. 25'x 12.8' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) 132" TH-1 105.0 O/A HORIZON ELEV. LOAMY SAND 10YR 4/2 B HORIZON LOAMY SAND 10YR 6/8 103.0 C HORIZON MED -FINE SAND 2.5Y 7/4 PERC AT 48" 94.0 NO GROUND WATER ENCOUNTERED 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSA11 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3'. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR R OVED . 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW.1�^--°4 HEALTH DEPT. SITE PLAN LOCATION: 24 DEEP BROOK RD. W. YARMOUTH, MA PREPARED FOR: PAUL & JANET LOISEL DATE: 6-16-15 SCALE: 1" = 20' BASS RIVER ENGINEERING J. McLkLtXN, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-385-3426 OR 508-364-9048