HomeMy WebLinkAboutEngineered Plan - Rev. 2015tu n� 1� IZ T.O.F 100.0 S 96.67 1 98.3 F.G. 11 SII INSTALL NEW OUTLET TEE AND FILTER 1000 GALLON H-10 EXISTING SEPTIC TANK umot4 STREET 85.001 0 0 0 COVER TO WITHIN 6" OF FINISHED GRADE COVER TO FINISHED GRADE 95.7 SEPTIC SYSTEM PROFILE TEST HOLE LOG DATE: 7/16/15 TEST BY: MIKE O'LOUGHLII` WITNESS: AMY VON HONE F.G. 98.8 +/- MINIMUM 2" PEASTONE OR PERC RATE: < 2 MIN PIPE TO BE LEVEL -GEOTEXTILE FABRIC /FOR 2' OUT OF D -BOX (� TEST HOLE # 1 r / I VENT WITH CHARCOAL 011 98.80 EL 94.37 \-93.69 93.85 111 20 D -BOX 6" COMPACT STONE OR COMPACTED B ASE CATCH BASIN Eq now r m CV LOAMY SAND I U1 AP 10Y 4/3 g" 98.05 EL BW LOAMY SAND 26" CTI 96.64 EL C1 FINE COARSE SAND 42" 10Y 5/8 94.50 EL C2 FINE SAND 2.5Y 7/2 4) 151.,, 100,0 T0F 'T / FILTER G/ TOP @ 94.57 0 0 0 0 0 0 0 0 0 0 0 /THRUNNNIN 93.57 (2) 500 GAL DRYWELL H-20 BOTTOM @ 91.57 WITH 3/4" -1 1/2" OF DOUBLE WASHED STONE 4' ON ENDS AND 3.58' ON SIDES 12.5' X 25' 5.87' 85.70 EL BOTTOM OF NO WATER #2 TEST HOLE r7 10 P ('1H KI TGD Gh h N VE T I 2O i � J 0 SEE �' o LID NOTE 3 ,o I� 00 07 4� SEE., NOTE 2 00 4a0 a- l 07 SEE NOTES 1 1/2 AT BEDROOM B EDROOM B EDROOM' SECOND FLOOR Permit valid for REPAIR OF' SEPTIC SYSTEM ONLY; dire to State and Local septic variances. Board, of llealth review and approval is required for any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department APPROVED 01 R17 r c' C Ae Date B ASIN BOTTOM OF PERK 41" PRESOAK > 15 MIN TEST HOLE # 2 n" 98.20 EL LOAMY SAND AP 10Y 4/3 g" 98.05 EL BW LOAMY SAND 26" 10Y 5/6 96.64 EL C1 FINE COARSE SAND 42" 10Y 5/8 94.50 EL C2 FINE SAND 2.5Y 7/2 NO WATER ENCOUNTERED 150" 1 186.30 EL BOTTOM OF PERK 41" PRESOAK > 15 MIN TEST HOLE # 2 n" 98.20 EL GENERAL NOTES 1. CONTRACTOR TO BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES, ABOVE & UNDERGROUND, PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 2. SEPTIC SYSTEM IS TO BE INSTALLED IN COMPLIANCE WITH 310 CMR 15.00: TITLE V. 3. THIS PLAN IS NOT TO BE USED FOR PROPERTY LINE DETERMINATION. 4. DESIGNER TO INSPECT & CERTIFY OVER -DIG, REQUIRED BY PLAN, AND FINAL INSPECTION BEFORE BACKFILL. 5. CONTRACTOR TO PROVIDE 48 HOUR NOTICE FOR ANY REQUIRED INSPECTIONS. 6. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE DISPOSAL. 7. THE TOP OF ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. 8. SOILS ARE FOUND UNSUITABLE OR DIFFERING FROM THOSE FOUND IN SOIL LOG CONTACT DESIGNER AND THE BOARD OF HEALTH. 9. AN OVERDIG IS REQUIRED IN BELOW PLAN OR IF UNSUITABLE SOIL FOUND A+B LAYERS, CLEAN GRANULAR SAND MEETING 310CMR 15.255(3) SHOULD BE USED AS FILL MATERIAL, 5' AROUND AND UNDER S.A.S. 10. -ALL-4" PIPE CONNECTIONS AT SEPTIC TANK AND D -BOX SHALL B E MORTARED IN PLACE. IF USING 18' PLASTIC RISER PIPES, THESE TOO SHALL BE MORTARED IN PLACE. DESIGN DATA DAILY FLOW: (3) BEDROOMS X 110 GPD = 330 GPD SEPTIC TANK: 330 GPD X 2 = 660 GPD USE: EXISTING 1000 GALLON H-10 SEPTIC TANK DISTRIBUTION BOX: USE: DB -6 H-20 SOIL ABSORPTION SYSTEM: USE: (2) 500 GAL DRYWELLS H-20 WITH DOUBLE WASHED STONE 4' ON ENDS AND 3.58' ON SIDES. SIDEWALL AREA: 75' X 2' X 0.74 = 111.00 GPD BOTTOM AREA: 12.5' X 25' X 0.74 = 231.25 GPD TOTAL AREA: 150 SQFT + 312.50 SQFT = 342.25 GPD NOTES 1. PUMPOUT EXISTING LEACHING PIT AND FILL IN WITH CONCRETE PRODUCT (FLOWABLE FILL) FROM CAPE COD READY MIX OR EQUAL. 2. REMOVE THE EXISTING OUTLET PIPE FROM THE TANK AND PATCH THE HOLE WITH HYDRAULIC CEMENT. 3. ADD 20' X 6" SLEEVE BETWEEN SEPTIC TANK AND DISTRIBUTION BOX OVER EXISTING WATER SERVICE 4. PATCH EXISTING DRIVEWAY WITH ASPHALT. VARIANCE REQUEST C MR 15.221 (7) TO ALLOW TOP OF D -BOX AND S.A.S > 3' FROM FINISH GRADE RELIEF NEEDED 1.23' HEALTH AGENT APPROVAL DATE SEWAGE PLAN ENGINEER: STEPHEN HAAS LOCATION: 2 VILLAGE LANE YARMOUTH PORT MA PREPARED FOR: EDWARD AND MARGARET RYAN_ a i 4f�£� s., �2xb d• SCALE: 1" = 10' DATE: JUL 28, 2015�,R JOB NUMBER: 7-28-15SP REVISION: AUG 14, 2015 SHEET NUMBER: 1 DRW BY KMJ MAP: 124 PARCEL: 17 PREPARED FROM CERTIFIED PLOT J. O' LO U G H LI N INC. PLAN BY DOWN CAPE ENGINEERING 714 MAIN STREET, YARMOUTH PORT, MA 02675 LAND SURVEYOR DATED 6/26/1918 (508) 362-4942 DRAWN BY: KENNETH JANSSON LOAMY SAND AP 10Y 4/3 g" 97.45 EL BW LOAMY SAND 26 10Y 5/6 96.04 EL C1 FINE COARSE SAND 52" 10Y 5/8 93.90 EL C2 FINE SAND 2.5Y 7/2 NO WATER ENCOUNTERED 150" 1 185.70 EL GENERAL NOTES 1. CONTRACTOR TO BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES, ABOVE & UNDERGROUND, PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 2. SEPTIC SYSTEM IS TO BE INSTALLED IN COMPLIANCE WITH 310 CMR 15.00: TITLE V. 3. THIS PLAN IS NOT TO BE USED FOR PROPERTY LINE DETERMINATION. 4. DESIGNER TO INSPECT & CERTIFY OVER -DIG, REQUIRED BY PLAN, AND FINAL INSPECTION BEFORE BACKFILL. 5. CONTRACTOR TO PROVIDE 48 HOUR NOTICE FOR ANY REQUIRED INSPECTIONS. 6. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE DISPOSAL. 7. THE TOP OF ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. 8. SOILS ARE FOUND UNSUITABLE OR DIFFERING FROM THOSE FOUND IN SOIL LOG CONTACT DESIGNER AND THE BOARD OF HEALTH. 9. AN OVERDIG IS REQUIRED IN BELOW PLAN OR IF UNSUITABLE SOIL FOUND A+B LAYERS, CLEAN GRANULAR SAND MEETING 310CMR 15.255(3) SHOULD BE USED AS FILL MATERIAL, 5' AROUND AND UNDER S.A.S. 10. -ALL-4" PIPE CONNECTIONS AT SEPTIC TANK AND D -BOX SHALL B E MORTARED IN PLACE. IF USING 18' PLASTIC RISER PIPES, THESE TOO SHALL BE MORTARED IN PLACE. DESIGN DATA DAILY FLOW: (3) BEDROOMS X 110 GPD = 330 GPD SEPTIC TANK: 330 GPD X 2 = 660 GPD USE: EXISTING 1000 GALLON H-10 SEPTIC TANK DISTRIBUTION BOX: USE: DB -6 H-20 SOIL ABSORPTION SYSTEM: USE: (2) 500 GAL DRYWELLS H-20 WITH DOUBLE WASHED STONE 4' ON ENDS AND 3.58' ON SIDES. SIDEWALL AREA: 75' X 2' X 0.74 = 111.00 GPD BOTTOM AREA: 12.5' X 25' X 0.74 = 231.25 GPD TOTAL AREA: 150 SQFT + 312.50 SQFT = 342.25 GPD NOTES 1. PUMPOUT EXISTING LEACHING PIT AND FILL IN WITH CONCRETE PRODUCT (FLOWABLE FILL) FROM CAPE COD READY MIX OR EQUAL. 2. REMOVE THE EXISTING OUTLET PIPE FROM THE TANK AND PATCH THE HOLE WITH HYDRAULIC CEMENT. 3. ADD 20' X 6" SLEEVE BETWEEN SEPTIC TANK AND DISTRIBUTION BOX OVER EXISTING WATER SERVICE 4. PATCH EXISTING DRIVEWAY WITH ASPHALT. VARIANCE REQUEST C MR 15.221 (7) TO ALLOW TOP OF D -BOX AND S.A.S > 3' FROM FINISH GRADE RELIEF NEEDED 1.23' HEALTH AGENT APPROVAL DATE SEWAGE PLAN ENGINEER: STEPHEN HAAS LOCATION: 2 VILLAGE LANE YARMOUTH PORT MA PREPARED FOR: EDWARD AND MARGARET RYAN_ a i 4f�£� s., �2xb d• SCALE: 1" = 10' DATE: JUL 28, 2015�,R JOB NUMBER: 7-28-15SP REVISION: AUG 14, 2015 SHEET NUMBER: 1 DRW BY KMJ MAP: 124 PARCEL: 17 PREPARED FROM CERTIFIED PLOT J. O' LO U G H LI N INC. PLAN BY DOWN CAPE ENGINEERING 714 MAIN STREET, YARMOUTH PORT, MA 02675 LAND SURVEYOR DATED 6/26/1918 (508) 362-4942 DRAWN BY: KENNETH JANSSON