Loading...
HomeMy WebLinkAboutEngineered Plan - 2002SYSTEM PROFILE ACCESS COVER TO WITH.N 6' OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO �! MINIMUM .75' OF COVER OVER PRECAST /` WITHIN 6' OF FIN. GRADE .EXISTING 1000 GALLON SEPTIC TANK <H-- 10 ) (RE -USE RUN PIPE LEVEL _ FOR FIRST 2' �47* 24.14' BAFFLE 24.31, �"� 6' CRUSHED STONE OR MECHANICAL o COMPACTION. (15.221 121) , DEPTH OF FLOW = 4' (2`F % SLOPE) TEE SIZES: 10,, INLET DEPTH = OUTLET DEPTH = 14' FOUNDATION- EXIST. 1.02-199 dd. i 2% SLOPE REQUIRED OVER SYSTEFI .2' DOUBLE WASHED PEAS TON.. i TEST HOLE LOGS ENGINEER: RICK JUDD, RS 27.0' WITNESS: LYNN MULKEEN DATE: 7/16/02 PERC. RATE = < 2 MIN/INCH 3' MAX. A cam' CLASS I SOILS P# 3/4' TO 1 1/2' DOUBLE WAS[ iiED STONE �, 5.3' SEPTIC TANK 11 D' BOX 2' LCiING Fr��CILCILITY ADJ. WATER AT EL. 18.26 REMOVE ANY CONTAMINATED SOILS WITHIN 5' I OF PROPOSED LEACHING FACILITY AND REPLACE WITH CLEAN MED. SAND RE -USE EXISTING SEPTIC TANK i f 24.4 INTO B LAYER). REPLACE WITH CLEAN MED. SAND. 0' 6" 13" 37" 72" 118" 132" FILL A /E LS 1OYR 4/2 BW LFS 10YR 6/4 C1 FS 2.5Y 6/4 C2 MED/FS OBS. WATER 2.5Y 7/2 SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED > DESIGN FLOW: 2_ BEDROOMS ( 110 GPD) = 220 GPD Ivy ^. 77( .rpri T)F `,'[zl�t '-!_!-1\j. ** SEPTIC TANK: 220 GPD ( 2 ) = 440 USE A 1000 GALLON SEPTIC TANK (RE -USE EXISTING) LEACHING: SIDES 2(28 + 9.83) (.58) (.74) - 32.4 BOTTOM: 28 x 9.83 (.74) - 203.7 TOTAL: 319.1 S.F. 236.1 GPD USE (4) STANDARD INFILTRATORS WITH 3.5' STONE AT SIDES AND 1.5' AT ENDS **2 BEDROOM DEED RESTRICTION REQUIRED LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 00 PROPOSED CONTOUR 100 EXISTING CONTOUR BOARD OF HEALTH i 'tel "7� MA j AA ROVED DATE off 508-362-4541 jl fox 508 362-9880 R' down cape engineering, inc. j; CIVIL ENGINEERS LAND SURVEYORS 939 vain st. yarmouth, ria 02675 ELEV. 26.1' 23.0' 16.26' 15.1' I i BUCK ISLAND RD. RpPO GRP 9�F` LOCUS IPJ LOCATION MAP NOT TO SCALE ASSESSORS MAP 49 PARCEL 108 WELL: MI W 29 ZONE: A ADJ: 2.0' NOTES" 1. DATUM IS APPROXIMATED FROM QUAD MAP s 2. MUNICIPAL WATER IS EXISTING �. MINIMUM .PIPE PITCH TO BE 1/8' PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS 10 BL AASHLI H-10. 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4' PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. PUMP & REMOVE (OR FILL W/CLEAN SAND) FAILED LEACH PIT I TI TL. E 5 SI TE PL_ All OF 28 LAKE ROAD IN THE TOWN OF: (WEST) YARMOUTH PREPARED FOR: BETH HAG 0 N 20 0 20 40 60 SCALE: 1" = 20' DATE: JULY 23, 2002 N t�fr.sF� \,a H. G5I rid o. 792 - A, DATE