Loading...
HomeMy WebLinkAboutEngineered Plans - 2015LOCUS DATA CURRENT OWNER ROBERT BASHIAN ELEANOR BASHIN PLAN REFERENCE 15/13 — 70-83 DEED REFERENCE 23722-339 ZONING DISTRICT R-25 FLOOD ZONE "X—OTHER" I ASSESSORS MAP PARCEL OVERLAY DISTRICT LOT AREA 22 316 NOT A ZONE II 13,422± S.F. SITE & SEWAGE REPAIR PLAN #18 wEST ROAD IN W. YARMOUTH, MASS DATE: JUNE 18, 2015 OWNER/APPLICANT: ROBERT BASHIAN. P.O. BOX 442 W. HYANNISPORT, MA 02672 508-862-6396 SHEET 1 OF 2 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU R VEY@YAH 00. COM 0Rjv� "I I'll "I E� I'll0I / "I8� / o N 0T 86 --6 - �� �,� PORT1ON Q� N / / 13,422± S.F. ---- \ \ / / \ EXISTING \ DRIVEWAY \ / i LIMITS OF "CAPE HYDRANT /o' COD" CELLAR \ / \ GJ( 7 OVERHEAD WIRES _� SPS cz� \ / -'BED / y� GAS 5.2' f -73 O \\ J0 \ � LA OF ktL SS9c \ EDWARD A. \ STONE No. 289 \ S ,STV BED #2 #1 \ BAT LIVING KITCHEN ROOM DINING ROOM BED #3 Im BENCHMARK CORNER OF BOTTOM / CONCRETE STEP ELEVATION 11.73 �6 / S / / CONCRETE BOUND FOUND (TYP) BATH AUND STI RD. LOCUS MAP NOT TO SCALE: 15-0114 PUMP, CRUSH AND REMOVE EXISTING CESSPOOL FROM SITE. PROPOSED 1500 GALLON SEPTIC TANK PROPOSED "D" BOX PROPOSED LEACHING S.A.S. (24) CHAMBERS 28 m cA. m CP. ONLY, due to State and local ' A\ Board ofhealth review and ,zppro cor- N �B5 �'' � 0 0 N y z z 0 Z 0 m LOCUS BROADWAY STI RD. LOCUS MAP NOT TO SCALE: 15-0114 PUMP, CRUSH AND REMOVE EXISTING CESSPOOL FROM SITE. PROPOSED 1500 GALLON SEPTIC TANK PROPOSED "D" BOX PROPOSED LEACHING S.A.S. (24) CHAMBERS LAUNDRY PIPING TO BE RECONNECTED TO SOIL PIPE AND DRYWELL ABANDONED. LOT 85 LOT 84 0 20 30 40 GRAPHIC SCALE: 1 INCH = 20 FEET 'TIC S\ STEM ptic variances. is requii d for alterations to :cling, me nt J,' 4y0l cA. Permit. valid for REPA112 m CP. ONLY, due to State and local ' s Board ofhealth review and ,zppro try futgre additions/renes. alio �B5 �'' sewage facilities and/or structures/4 x,10.5' 110 Y.arttoulh tlealtla Ue.p; .1' APP OVi LAUNDRY PIPING TO BE RECONNECTED TO SOIL PIPE AND DRYWELL ABANDONED. LOT 85 LOT 84 0 20 30 40 GRAPHIC SCALE: 1 INCH = 20 FEET 'TIC S\ STEM ptic variances. is requii d for alterations to :cling, me nt J,' 4y0l TCF = 12.26 GRADE 10.7 4A= 38'CS=0.02 v B= 18'OS=0.02 REPLACE WITH 4" PVC SCH 40 INV.= JA* 9.15 K A INV.= 10.01 6'-0" 4'-9" B INV.= 9.51 DATUM: VERTICAL DATUM: NAD -88 BENCH MARK USED: CORNER OF CONCRETE STEP ELEVATION 11.73 15-0114 SITE & SEWAGE REPAIR PLAN RAISE COVERS TO WITHIN 6" OF FINISH GRADE FINISH GRADE H-20-24" MANHOLE ELEV. 10.9 TO GRADE FINISH GRADE ELEV. 11.0 ELEV. 11.0 12'®S=0.01 N TOP ELEV 8.95 4" PVC SCH 40 8' ®S= 0.005 1 1 1 1 1 1 1 10"TEE 14" TEE INV.= MAY 2015 INSTALL 8'95 GAS BAFFLE INDEX WELL: WELL ZONE: T LINV= 4'-1" LIQUID LEVEL 6 KWELL DEPTH: DEPTH OF WATER: WELL ADJUSTMENT: DEPTH OF ADJ.: 7.64 10.0 1.3' 8.7' BOT. INV.= 8.66 o 4.40 PROPOSED H-20 1,500 EL. = 3.9 104" GALLON SEPTIC TANK SET ON LEVEL STABLE BASE. EL. = 2.6 120" #1 WE -ST ROAD IN W. YARMOUTH, MASS DATE: JUNE 18, 2015 OWNER/APPLICANT: ROBERT BASHIAN P.O. BOX 442 W. HYANNISPORT, MA 02672 508-862-6396 SHEET 2 OF 2 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU R VEY@YAH 00. COM CONSTRUCTION NOTES: 00 OBSERVATION PORT(S) TO GRADE / SCREW ON CAP ION 11.9 N (24) 34" x 48" x 12" CHAMBERS INV.=8.62QUIK "4" INFILTRATORS 24 CHAMBERS IN BED FORMAT a a 16.0' U -)o 4 CHAMBERS 0 6 PER ROW c� ui 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. VEHICULAR TRAFFIC, PARKING OF VEHICLES AND PLACING MATERIALS OVER THE SEPTIC TANK, DISTRIBUTION BOX AND S.A.S. AREA IS PROHIBITED GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS OTHERWISE SPECIFIED. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. MAGNETIC TAPE ON ALL COMPONENTS. 2 OBSERVATIONT PORT ^' 7.95 3.9 I --2.83'--I--2.83' +---2.83'---2.83'------2.83'---I---2.83--I 17.0' ---I END VIEW SYSTEM DESIGN EXISTING DESIGN FLOW 3 BEDROOMS AT 110 GPB/D 3,32 GPD REQUIRED SEPTIC TANK 330 x_2 '-= _____660 GAL. SEPTIC TANK PROVIDED = _ 500_GAL. H-20 SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE -_ <2 ____MIN./INCH LONG TERM APPL. RATE-2t!4--GPD/S.F. SIZE OF LEACHING SYSTEM PROVIDED: 330 _ 0.74 SF/GPD = 446 S.F. MIN. REQ, USING 4 CHAMBERS IN 6 ROWS (24 UNITS) AND NO STONE AROUND QUIK "4" INFILTRATORS 4.73 SF/LFX(6x14)=454S.F 454 x 0.74 G/SF = 336 GPD 336 GPD PROV > 330 GPD REQ.= 6 GPD RES. NO (GARBAGE DISPOSAL / GRINDER ALLOWED) DTH #1 0 INDICATES DEEP TGCT 1-1!11 F D.T.H. #1 0 DATE: 6-4-2015 GROUND ELEV. 12.6 ADJ. GROUNDWATER 3.9 LOAMY SAND C'INDICATES 10T 8 4/2 P-1 42" PERC TEST 8" 1/7 I® NO MOTTLING LOAMY SAND ry J NO WEEPING 7.5YR 5/6 26" , EL. =10.4 RQl8T DATE OF WELL: MAY 2015 �4NITAR1A INDEX WELL: WELL ZONE: MIW 29 A 42" KWELL DEPTH: DEPTH OF WATER: WELL ADJUSTMENT: DEPTH OF ADJ.: 7.64 10.0 1.3' 8.7' C MEDIUM SAND 10YR 7/6 EL. = 3.9 104" EL. = 2.6 120" 104" INDICATES ADJ. GROUNDWATER 120" OBS. GROUNDWATER NO OBSERVED GROUNDWATER DEPTH TO BOTTOM OF HOLE 11.0' VARIANCES REQUESTED CMR 15.401: TO ALLOW 4' OF SEPARATION IN LIEU OF 5' EL. = 1.6 1132" B.O.H. AMY VON HONE SOIL EVALUATOR ED. STONE BACKHOE OPERATOR. ELLIS BROTHERS (LARRY) SOIL TYPE: 1- PERC RATE: <2 MIN. PER INCH LOADING RATE: 0_74 GAL/SF/MIN