Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 2015LEGEND BUILDING /////////////7777' �i PROPERTY LINE W/ S81 *56'34"E BEARING DISTANCE 116.23' DIG SAFE EXCAVATORS BEFORE YOU DIG CONTACT THE DIG SAFE CENTER TO PREVENT DAMAGE TO TELEPHONE, GAS OR ELECTRIC UNDERGROUND FACILITIES OF MEMBER UTILITIES, CALL TOLL FREE 1-888—DIG—SAFE. MASSACHUSETTS STATE LAW REQUIRES NOTIFICATION AT LEAST THREE BUSINESS DAYS BEFORE YOU START DIGGING OPERATIONS. IN AN EMERGENCY, CALL IMMEDIATELY SCALE:1 "=10' 6.9' w � °'- O c i o � x ,ad o 00 z / p N V) z 0.9' ' LOT 169 1 1/2 STY 9' WOOD I #100 F.FL.EL.=100.0 1 (ASSUMED) i 1 1 j! 6.0' 1.6' jl 1 STORY BENCHMARK EL.=100.0 i f 23.1 l� d� j N ,+V ti g� ji i i is I l NOTES: 1. THE CONTRACTO, SHALL BE RESPONSIBLE FOR VERIFYING AND DETERMINING THE LOCATION, SIZE AND ELEVATION OF ALL EXISTING UTILITIES, SHOWN OR NOT SHOWN ON THIS PLAN. PRIOR TO ANY CONSTRUCTION. THE ENGINEER SHALL BE NOTIFIED IN WRITING OF ANY UTILITIES FOUND INTERFERING WITH THE PROPOSED CONSTRUCTION AND APPROPRIATE REMEDIAL ACTION BEFORE PROCEEDING WITH THE WORK. 2. THE LOCATION OF ALL UTILITIES SHOWN HEREON ARE APPROXIMATE AND ARE BASE ON THE D FIELD LOCATION 'OF ALL VISIBLE STRUCTURES SUCH AS CATCH BASINS, MANHOLES, WATER GATES, ETC. ANd GOVERNMENT AGENCIES. l ;I N90' 00 00"E 100.00' a o LOT 165 & 167 AREA 12.875 e"' MAP 22 PARCEL 305 0 / 112.3' / 1 • , o0 10.0' H o w /� I PROPOSED LEACHING FIELD 3 v=i 1 ( (6) 4" PVC SCH-40 PERFORATED I IMBEDDED IN A (30.0'x26.0') STONE BED (SEE DETAIL) . N o 10 t4 PVC ( YARMOUTH, MASSACHUSETTS 12.3' 1 f4"PVC I SUBMISSION: BLDG. PERMIT EXISTING 191t4"PVC REQUIRED EXISTING PROPOSED DRY—WELLS 25,000s.f. 12,875s.f. N/C TO BE REMOVED) 150' 100.0' N/C GARAGE c 30.0' 21.6' N/C SIDE SETBACK 15.0' 6.0' N/C \ 20.0' 43.4' N/C 20.0' 25% 11.6% 18.2%, PROPOSED 0 c N/C RELOCATED SIEPS O I 3if4"PVC E 3't4"PVC N WOODXISTINI / N PERC.) WATER 24't4 PVC b - EL.=85.30 _ DECK EL. -85.10 o EXISTING PROPOSED DB -9 DISTRIBUTION C-4 BOX, H2O RATED '- o OIOOI aIG. +Q�G I 24.0. SEPTIC TANK 1 (TO BE REMOVED) `-� PROPOSED RO OOSED 1,500 GA LON,SEPT TANK � 31.7' E MEN H PROPOSED SILT )FENCE LOT 163 � r174, ' Date MAY 2 6 2015 HEALTH DEPT. ZONING CHART YARMOUTH, MASSACHUSETTS 138.0' SUBMISSION: BLDG. PERMIT REGULATION REQUIRED EXISTING PROPOSED PROPOSED 25,000s.f. 12,875s.f. N/C LOT FRONTAGE 150' 100.0' N/C GARAGE c 30.0' 21.6' N/C SIDE SETBACK 15.0' 6.0' N/C ADDITION N 20.0' 43.4' N/C MAX BLDG COVERAGE 25% 11.6% 18.2%, DH#1 22 1 16 N/C j WATER 12.01 - EL.=85.30 24.0. /M � 1 6' 'Ii I /I / I ¢ � I I a I I I 3 V) w_ a PROPOSED CONC. WALK GRAVEL DRIVEWAY I , � I I I I I I i 00.00' o 13 N89'49'41 "W PROPOSED SILT FENCE (rep) LEWIS ROAD E MEN H PROPOSED SILT )FENCE LOT 163 � r174, ' Date MAY 2 6 2015 HEALTH DEPT. ZONING CHART YARMOUTH, MASSACHUSETTS ZONE: R-25 SUBMISSION: BLDG. PERMIT REGULATION REQUIRED EXISTING PROPOSED LOT AREA 25,000s.f. 12,875s.f. N/C LOT FRONTAGE 150' 100.0' N/C FRONT SETBACK 30.0' 21.6' N/C SIDE SETBACK 15.0' 6.0' N/C REAR SETBACK 20.0' 43.4' N/C MAX BLDG COVERAGE 25% 11.6% 18.2%, MAX SHAPE FACTOR 22 1 16 N/C r � .10SEPH s f`F :TES? w•��' A A e SITE PLAN YARMOUTH, MASSACHUSETTS SHOWING PROPOSED CONDITIONS AT #100 LEWIS ROAD SCALE: 1 in.=1 Oft. DATE: NOVEMBER 6, 2014 REVISED: APRIL 16, 2015; MAY 14, 2015 PROJECT: VTP 4ssoc i Alis INC. LAND SURVEYORS — CIVIL ENGINEERS. 132 ADAMS STREET 2ND FLOOR SUITE 3 NEWTON, MA 02458 (617) 332-8271 SHEET 1 OF 2 'I PROPOSED H2O RATED, DB— DISTRIBUTION BOX 18" ACCESS PROVIDE ZABEL MODEL A1800 EFFLUENT TEE FILTER 4" PVC SCH-40 PERFORATED PIPE 4" LAYER OF4 COVER (6" BELOW GRADE MAINTAIN ANNUALY (SLOPE 0.005 FEET PER FOOT) o APPROVED SEPTIC GRAVEL OBSERVATION 21 2. SEPTIC TANK SIZE AVERAGE DAILY FLOW = 550 X 200% = 1,100 GAL (MIN) 2" LAYER OF 3/8" DOUBLE WASHED STONE F.G. EL.=96.50 RUN LEVEL, 2 FEE M SEPTIC TANK PROVIDED = 1,500 GALLON, TWO COMPARTMENT TANK rn rn rn M DESIGN PERCOLATION RATE = <2 M.P.I. BOTTOM LOADING = 0.74 GAL/S. 4" PVC 36" ws 4. 3'± GROUNDWATER EL.=86.2 x v A—Loamy Sand, Soft IPE —\ INV. EL.=Varies 000 SYSTEM PROFILE BOT. EL.=Varies +: y:':.: .. ..;•: 'c ; ...,.;. ..S •.ti ;�„ ; ' ;..y.. ; �- :�; :�: ': •'^ 12 6" STONE BASE ( b —! Kv, DESIGN HYDRAULIC LOADING = 577 GALS/DAY 4',ri ,�•�., , 'x;: ,•, ,•..� ,....�.:.: t�� a 38" THIS DESIGN IS IN ACCORDANCE WITH THE COMMONWEALTH OF 1 1/2" DOUBLE MASSACHUSETTS (TITLE 5) REQUIREMENTS AND THE REQUIREMENTS (� WASHED STONE OF THE TOWN OF YARMOUTH. C— Meda Sand, Loose PVC END CAP (TY') 4" PVC SCH-40 PERFORATED IMBEDDED IN A (30.0'x26.0') STONE BED (TYP) 0 n 1 1/2" Dot,��� WASHED STONE 26'-0" n 17 A7, ", . I cp I e s e o • • • • e e e e e e 3' . (TYP) DIG SAFE EXCAVATORS BEFORE YOU DIG CONTACT THE DIG SAFE CENTER TO PREVENT DAMAGE TO TELEPHONE, GAS OR ELECTRIC UNDERGROUND FACILITIES OF MEMBER UTILITIES, CALL TOLL FREE 1-888—DIG—SAFE. MASSACHUSETTS STATE LAW REQUIRES NOTIFICATION AT LEAST THREE BUSINESS DAYS BEFORE YOU START DIGGING OPERATIONS. IN AN EMERGENCY, CALL IMMEDIATELY N I I o i NOTE: All Tank & Dist. Box covers to be within 6" of finish grade, use risers if necessary N.T.S. 12" 19" k" METAL FRAME & COVI WITHIN 6" FINISH GRADE F.G. EL.=96.80 '-0" LIQUID 6" STONE BASE to 0 M PROPOSED 1,500 GALLON, TWO COMPARTMENT SEPTIC TANK 0 TANK TO BE H10 RATED c c 4" PVC PIPE 15't WRAP POLES TOGETHER AND JOIN 2x2x,V WOODEN - 4" PVC SCH-40 POSTS (FRONT D—BOX) (TY') v •r + v + + FILTER FABRIC v r • V + POLE RESOURCE AREA •y`ry " a s" PLACE 6" OF FABRIC ALONG TRENCH AWAY FROM HAY BALES, BACKFILL AND TAMP SILT FENCE NOT TO SCALE PLAN VIEW N.T.S. LEACHING TRENCH N.T.S. 4" PVC PROPOSED H2O RATED, DB -9 DISTRIBUTION BOX, 18" ACCESS COVER (6" BELOW GRADE) 4" PVC (TYP) 4" LAYER OF4 24" METAL COVER ACCESS 6" BELOW GRADE 0 4" PVC i i 1. ESTIMATED HYDRAULIC LOADING 5 BDRM AT 110 GALS/DAY = 550 G.P.D. o APPROVED SEPTIC GRAVEL OBSERVATION 21 2. SEPTIC TANK SIZE AVERAGE DAILY FLOW = 550 X 200% = 1,100 GAL (MIN) Ki RAKE LEVEL ri 4' vi M SEPTIC TANK PROVIDED = 1,500 GALLON, TWO COMPARTMENT TANK rn rn rn M DESIGN PERCOLATION RATE = <2 M.P.I. BOTTOM LOADING = 0.74 GAL/S. 3' S 23'-0" S 37'f DEPTH ws 4. 3'± GROUNDWATER EL.=86.2 x v A—Loamy Sand, Soft 1011- 10 YR 4,3 SYSTEM PROFILE PVC END CAP (TY') 4" PVC SCH-40 PERFORATED IMBEDDED IN A (30.0'x26.0') STONE BED (TYP) 0 n 1 1/2" Dot,��� WASHED STONE 26'-0" n 17 A7, ", . I cp I e s e o • • • • e e e e e e 3' . (TYP) DIG SAFE EXCAVATORS BEFORE YOU DIG CONTACT THE DIG SAFE CENTER TO PREVENT DAMAGE TO TELEPHONE, GAS OR ELECTRIC UNDERGROUND FACILITIES OF MEMBER UTILITIES, CALL TOLL FREE 1-888—DIG—SAFE. MASSACHUSETTS STATE LAW REQUIRES NOTIFICATION AT LEAST THREE BUSINESS DAYS BEFORE YOU START DIGGING OPERATIONS. IN AN EMERGENCY, CALL IMMEDIATELY N I I o i NOTE: All Tank & Dist. Box covers to be within 6" of finish grade, use risers if necessary N.T.S. 12" 19" k" METAL FRAME & COVI WITHIN 6" FINISH GRADE F.G. EL.=96.80 '-0" LIQUID 6" STONE BASE to 0 M PROPOSED 1,500 GALLON, TWO COMPARTMENT SEPTIC TANK 0 TANK TO BE H10 RATED c c 4" PVC PIPE 15't WRAP POLES TOGETHER AND JOIN 2x2x,V WOODEN - 4" PVC SCH-40 POSTS (FRONT D—BOX) (TY') v •r + v + + FILTER FABRIC v r • V + POLE RESOURCE AREA •y`ry " a s" PLACE 6" OF FABRIC ALONG TRENCH AWAY FROM HAY BALES, BACKFILL AND TAMP SILT FENCE NOT TO SCALE PLAN VIEW N.T.S. LEACHING TRENCH N.T.S. 4" PVC PROPOSED H2O RATED, DB -9 DISTRIBUTION BOX, 18" ACCESS COVER (6" BELOW GRADE) 4" PVC (TYP) TEM PROPOSED 1,500 GALLON, TWO COMPARTMENT SEP11C TANK Proposed House j; F.FL.EI.=100.00 I i F.G. EL.=97.00 I r ,1 0 M alc ti I N I 10'-6" 24" METAL COVER ACCESS 6" BELOW GRADE 0 4" PVC i i 1. TEM PROPOSED 1,500 GALLON, TWO COMPARTMENT SEP11C TANK Proposed House j; F.FL.EI.=100.00 I i F.G. EL.=97.00 I r ,1 0 M alc ti I N I )TE: ALL UNDERGROUND UTILITY LOCATIONS AND ELEVATIONS ARE APPROXIMATE AND MUST BE VERIFIED AT TIME OF CONSTRUCTION. CALL DIG SAFE: 1-888-344-7233 VARIES GR4DE — MAGNETIC (SEE NOTES) PE 4" SLOPE SIDE WALLS OR ORDINARY PROVIDE ADEQVATE LEAN BAC FILL SHORING AND/OR SEE NOTES BRACING TO MAINTAIN A STABLE EXCAVATION AND 4" SCHD. 40 PVC PIPE CONDIDTIONS FE WORKING PIPE BEDDING COMPACTED SUBGRADE TYPICAL UTILITY TRENCH NOTES: 1. 4" SAND CUSHION REQUIRED, INCREASE TO 8" AT ALL LEDGE OR PIPE CROSSING 2. NO STONE GREATER THAN 6" TO BE PLACED OVER PIPE TO FINISH GRADE 3. NO STONE GREATER THAN 1 " WITHIN 12" OF PIPE. 4. CONTRACTOR TO PLACE METALLIC DETECTION TAPE FOR THE FULL LENGTH OF THE PIPE RUN, IN ACCORDANCE WITH 310 CMR, SECTION 15.221(12) e -41 OFF. ,� �Y J P •v SOIL DEPTH A—Loamy Sand, Soft 10" 10 YR 4,3 B—Med. Sand, Loose 10 YR 6,6 38to C— Med. Sand, Loose 2.5 YR 7,6 144 D.H.-2 ELEV. 96.60 No Mottling No Weeping Water EI.=85.10 No Refusal NOTE: HIGH GROUNDWATER DEPTH 11.5 FEET. NOTE: SOIL TESTING OBSERVED BY BRUCE MURPHY, HEALTH AGENT. PERCOLATION TEST DATA TEST PIT DATE DEPTH ELEVATION RATE TP -1 3-26-15 40" 96.6± <2 MPI NOTE: NO PUBLIC WATER SUPPLIES WITHIN 400 FEET OR PRIVATE WATER SUPPLIES WITHIN 100 FEET OF THE PROPOSED LEACHING AREA, UNLESS SHOWN ON PLAN. I CERTIFY THAT ON NOVEMBER 20, 2005 1 HAVE PASSED THE EXAMINATION APPROVED BY THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND THAT THE ABOVE ANALYSIS HAS BEEN PERFORMED BY ME, CONSISTENT WITH THE REQUIRED TRAINING, EXPERTISE, AND EXPERIENCE DESCRIBED IN 310 CMR 15.018 (2). APPROVAL No. SE3015. SOIL LOGS BY JOSEPH R. PORTER, ON FILE W/BOARD OF HEALTH APPLICANT: A.THOMAS DEMAIO 7 PIERREPONT ROAD NEWTON, MA 02462 SEWAGE DISPOSAL SYSTEM 100 LEWIS ROAD YARMOUTH, MASSACHUSETTS SCALE: AS NOTED DATE: NOVEMBER 6, 2014 REVISED: APRIL 16, 2015; MAY 14, 2015 VTP A SSO CIA TES, INC. LAND SURVEYORS — CIVIL ENGINEERS 132 ADAMS STREET, 2ND FLOOR, SUITE 3 NEWTON, MASSACHUSETTS PH. -(617) 332-8271 / FAX. (617) 969-2330 DESIGNED BY J.R.P DRAWN BY N.R.M. CHECKED BY S.E.P VVI3 I m 910 M_ y� No. DESCRIPTION DATE . REVISIONS 209216bp5—Septic System-5.dwg SHEET 2 OF 2 .DESIGN DATA OBSERVATION TEST HOLES AND PERCOLATION TEST DATA 1. ESTIMATED HYDRAULIC LOADING 5 BDRM AT 110 GALS/DAY = 550 G.P.D. OBSERVATION TEST HOLE 2. SEPTIC TANK SIZE AVERAGE DAILY FLOW = 550 X 200% = 1,100 GAL (MIN) SCALE: 1 4' DATE: MARCH 26, 2015 SEPTIC TANK PROVIDED = 1,500 GALLON, TWO COMPARTMENT TANK 3. DESIGN PERCOLATION RATE = <2 M.P.I. BOTTOM LOADING = 0.74 GAL/S. SOIL DEPTH D.H.-1 ELEV. 96.80 4. LEACHING AREA = BOTTOM AREA = 780 S.F. X 0.74 GALS/S.F. = 577 G,P.D. A—Loamy Sand, Soft 1011- 10 YR 4,3 5. REQUIRED HYDRAULIC LOADING = 550 GALS/DAY Sand, Looseed B—MM . DESIGN HYDRAULIC LOADING = 577 GALS/DAY 6,6 38" THIS DESIGN IS IN ACCORDANCE WITH THE COMMONWEALTH OF MASSACHUSETTS (TITLE 5) REQUIREMENTS AND THE REQUIREMENTS OF THE TOWN OF YARMOUTH. C— Meda Sand, Loose 2.5 YR 7,6 No Mottling No Weeping HIGH GROUNDWA .R ELEVATION Water EI.=85.30 WELL NUMBER: S4-29 ZONE: A DATE: MARCH 2015 ADJUSTMENT=1.1' No Refusal " _ I _ A 120" )TE: ALL UNDERGROUND UTILITY LOCATIONS AND ELEVATIONS ARE APPROXIMATE AND MUST BE VERIFIED AT TIME OF CONSTRUCTION. CALL DIG SAFE: 1-888-344-7233 VARIES GR4DE — MAGNETIC (SEE NOTES) PE 4" SLOPE SIDE WALLS OR ORDINARY PROVIDE ADEQVATE LEAN BAC FILL SHORING AND/OR SEE NOTES BRACING TO MAINTAIN A STABLE EXCAVATION AND 4" SCHD. 40 PVC PIPE CONDIDTIONS FE WORKING PIPE BEDDING COMPACTED SUBGRADE TYPICAL UTILITY TRENCH NOTES: 1. 4" SAND CUSHION REQUIRED, INCREASE TO 8" AT ALL LEDGE OR PIPE CROSSING 2. NO STONE GREATER THAN 6" TO BE PLACED OVER PIPE TO FINISH GRADE 3. NO STONE GREATER THAN 1 " WITHIN 12" OF PIPE. 4. CONTRACTOR TO PLACE METALLIC DETECTION TAPE FOR THE FULL LENGTH OF THE PIPE RUN, IN ACCORDANCE WITH 310 CMR, SECTION 15.221(12) e -41 OFF. ,� �Y J P •v SOIL DEPTH A—Loamy Sand, Soft 10" 10 YR 4,3 B—Med. Sand, Loose 10 YR 6,6 38to C— Med. Sand, Loose 2.5 YR 7,6 144 D.H.-2 ELEV. 96.60 No Mottling No Weeping Water EI.=85.10 No Refusal NOTE: HIGH GROUNDWATER DEPTH 11.5 FEET. NOTE: SOIL TESTING OBSERVED BY BRUCE MURPHY, HEALTH AGENT. PERCOLATION TEST DATA TEST PIT DATE DEPTH ELEVATION RATE TP -1 3-26-15 40" 96.6± <2 MPI NOTE: NO PUBLIC WATER SUPPLIES WITHIN 400 FEET OR PRIVATE WATER SUPPLIES WITHIN 100 FEET OF THE PROPOSED LEACHING AREA, UNLESS SHOWN ON PLAN. I CERTIFY THAT ON NOVEMBER 20, 2005 1 HAVE PASSED THE EXAMINATION APPROVED BY THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND THAT THE ABOVE ANALYSIS HAS BEEN PERFORMED BY ME, CONSISTENT WITH THE REQUIRED TRAINING, EXPERTISE, AND EXPERIENCE DESCRIBED IN 310 CMR 15.018 (2). APPROVAL No. SE3015. SOIL LOGS BY JOSEPH R. PORTER, ON FILE W/BOARD OF HEALTH APPLICANT: A.THOMAS DEMAIO 7 PIERREPONT ROAD NEWTON, MA 02462 SEWAGE DISPOSAL SYSTEM 100 LEWIS ROAD YARMOUTH, MASSACHUSETTS SCALE: AS NOTED DATE: NOVEMBER 6, 2014 REVISED: APRIL 16, 2015; MAY 14, 2015 VTP A SSO CIA TES, INC. LAND SURVEYORS — CIVIL ENGINEERS 132 ADAMS STREET, 2ND FLOOR, SUITE 3 NEWTON, MASSACHUSETTS PH. -(617) 332-8271 / FAX. (617) 969-2330 DESIGNED BY J.R.P DRAWN BY N.R.M. CHECKED BY S.E.P VVI3 I m 910 M_ y� No. DESCRIPTION DATE . REVISIONS 209216bp5—Septic System-5.dwg SHEET 2 OF 2