Loading...
HomeMy WebLinkAbout2015 May 11 - Email to VTP Assoc. Re: RevisionsmEll;r25 A. Thomas DeMaio vonHone, Amy 'Pull General Manager From: vonHone, Amy 990 LaGrange Street Sent: Monday, May 11, 2015 1:40 PM HOLYHOOD CEMETERY West Roxbury, MA 02132 To: 'vtp@vtpassociates. com' A ssS o C i A T r O N Phone: 617-327-1010 Cc: 'tomd@holyhood.com' Fax: 61 -0526 Subject: 100 Lewis Road, Yarmouth Plan Revisions ail: tomd@holyhood.com .com Joe/Marc- On behalf of Bruce Murphy, Director, we have reviewed the revised septic plan and supplemental information and have the following revisions/comments that will need to be addressed prior to approval of the septic plan: �-1. Show the existing waterline Q. Label the Benchmark �3. Provide a Locus Map List the Assessor Map 22 Parcel 305 5. The plan is titled as a "Topographic Site Plan" but there are no contours provided on the site plan. Please add the existing contours or spot elevations in order to compare the septic component elevations to the existing grades of the lot. �t.6. Remove the note on Page 2 under Design Data that the system is designed for a garbage disposal. If the owner is installing a garbage disposal, the leach facility will need to be enlarged to accommodate the disposal. The groundwater adjustment calculations were based off of the wrong monitoring well. The correct well to use is MIW-29, Zone A, March 2015 adjustment = 1.1'. The groundwater adjustment should be EL. 86.2 which needs to be corrected on Page 2 in the System Profile. The proposed elevation of the system is still ok with the correct groundwater adjustment. We do not need corrected supplemental sheets. The correct groundwater adjustment information (well, zone, date, adjustment) can simply be 08. P added to the plan. rovide a floor plan with all rooms labelled (hand sketch, not to scale) which will be attached to the septic application for comparison of number of bedrooms existing to the septic capacity. A pipe and stone leach field of the same size (26'x 30') will provide the same leaching capacity and probably be considerably cheaper than the current design of precast and stone. If the leach facility design changes, the plans will need to be revised to reflect that change. Please call or email with questions. Our office will need a minimum of 4 revised plans when the changes are finalized (this number includes the plans needed for the Building Permit application for the proposed garage). Thank you, Amy Amy L. von Hone, R.S., C.H.O. Assistant Health Director Yarmouth Health Department 1146 Route 28 South Yarmouth., MA 02664 (0) 508-398-2231 X1241 (F) 508-760-3472 avonhoneavarmouth.ma.us a /iwiS Iu