Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2015N ACCESS COVERS MUST BE WITHIN INSPECTION 9" MINIMUM. 6` OF FINISH GRADE PORT 3' MAXIMUM COVER FIRST 2' TO BE LEVEL CLEAN SAND BACKFILL AROUND AND 2' OVER CHAMBERS ` DIEM PIPE s' 98.5 6 98.4 98.1 / I " S' 40 MILL POLY �* GAS BAFFLES 98.27 � � 98.02 97, I VAPOR BARRIER 1000 c Soo c 6 OUTLET 24 HIGH CAPACITY INFILTRATOR a D -BOX CHAMBERS IN BED FORMATION 1500 GAL H-20 95.5 2 COMPARTMENT 6" CRUSHED STONE OR SEPTIC TANK COMPACTED BASE PROFILE : NOT TO SCALE �o _ ADJUSTED GROUNDWATER. EL -92.0 L_ OBSERVED GROUNDWATER. EL -89.5 � { V SBM-C$fDH"EL 101.19 FND UP ,LOT X32 I/ I. 744± IS . F. CATCH easrN A �� t � � RIM -99.83 1011.2 LEACH11 / 1 It \\\ \\ \\ Z t \ \ \ t 1 1500 GALLON , PIT \\tel 2GOMPARTMENT cNSEPTIC TANK -C \ \ \c,.� • ODI 0 of It ZE: dI\ o�L \\ o'y� �p� \ 100.36'' TP 1C, r Permit valid for REPAIR OFF SEPTIC SYSTEM 99-3, � + ONa.Y, due to Stale and Local septic variances. o I FL,� \ I �--- - - - - 'TP 2 ti Board of Health review and approval is required for any, fut�yre additions/renovations/alterations to 4r y sewage facilities and/or.structures/dwelling. - \ Yarmouth N.eal(h Department \o' 100.5 5' \ ' �lE t - - - - - -SOIL REMOVAL \ \\ \ ' 6 ZA YI ' SEE NOTE 9. �� \\ v���\ 1216.2 Z30.00- 40 MILL POLY ,�8&Jc ®ate \ $ VAPOR BARRIER 24 HIGH CAPACITY \ INFILTRATOR CHAMBERS LOCUS MAP SECOND FLOOR PLAN 0 /0 20 40 INVERT ELEVATIONS: DESIGN CRITERIA: I N`VER T IN SEPTIC TANK: 98.65 DESIGN FLOW: INVERT OUT SEPTIC TANK: 98.4 3 BEDROOMS AT 1/0 G.P.D. PER INVERT IN DIST. BOX. 98.27 BEDROOM EQUALS 330 G.P.D. INVERT OUT DIST. BOX: 98.1 -# I LAVER T IN LEACH CHAMBER: 98.02 W 1 TH A GARBAGE GRINDER B J T TOM OF LEACH CHAMBER: 97.1 UNDERGROUND TELEPHONE LINE - CTV- SEPTIC TANK REQUIRED: AQQJUSTED GROUND WATER: -1 92.0 330 G.P.D. X 200x - 660 GAL. 2 COMPARTMENT OBSERVED GROUND WATER: 89.5 SEPTIC TANK PROVIDED: 1500 GAL. MINIMUM BQTTOM OF TEST HOLE #/: 89.0 r INDEX WELL AIW 247. ZONE B SOIL ABSORPTION SYSTEM REQUIRED: MARCH 20/5 READING -23.2% ADJ-2.5' DESIGN PERC RATE ( 5 MIN/INCH j SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 330 GPD / 0.74 GPD/SF - 446 SF x 150-- -669 SF PROVIDED: 24 HIGH CAPACITY INFILTRATOR CHAMBERS. 150'x 4.73 SF/FT - 709 S.F. 709 S.F. x 0.74 - 525 GPD SOIL TEST PIT DA TA s 1 NO 1 CA TES V I NO 1 CA TES PERCOLATION _ OBSERVED TEST GROUNDWATER iTP #1 TP #2 0- HORIZON TEXTURE COLOR 100.2 0' HORIZON TEXTURE COLOR l LOAMY LOAMY FILL SAND F l L L SAND 24' -------------------- 98.2 24' -------------------- FILL SENIUM FILL SENIUM 90 -------------------- 92.7 42" MED I 10 Cl SENIUM 6/6R 60" -------- 93.5 C / MEDIUM IOYR SAND 6/6 ----------------- 89.5 98.5 96.5 =C2 LOAM 6/2 134 ' 89.0 /08 " DATE. APRIL 2. 2015 �. TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RA TE: ( 2 MIN/INCH IN CLEAN MED SAND FILL JOHN N Z. DEMAREST,JR o No. 36859_, •may GENERAL NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM I S ASSUMED. FOR BENCH MARKS SET. SEE S I TE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D - BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL "OIG -SAFE". 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING LEACH PIT TO BE PUMPED DRY AND BACKFILLED. 9. ALL UNSUITABLE MATERIAL (FILL. LOAMY SAND ONLY) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. VARIANCES REOU I RED : TITLE 5. MAXIMUM FEASIBLE COMPL 1 ANCE SECTION 15.211:(/) MINIMUM SETBACK DISTANCES 20' IS REQUIRED BETWEEN THE SAS AND THE FOUNDATION. 16' I S PROVIDED. A 4' VAR I ANCE I S REQUESTED. TOWN OF YARMOUTH SUBSURFACE SEWAGE DISPOSAL REGULATIONS REGULATION 3.7: DISTANCES & LOCATION OF DISPOSAL FACILITIES l00' IS REQUIRED BETWEEN THE SAS AND A WETLAND. 84' IS PROVIDED. A 16' VARIANCE IS REQUESTED. S EP T l C SYS TEM Di7S l GN 3 LEX I NOTON LANE. MAP 1 / 0 . PARCEL OS YARMOUTHPOR T . MA. G� PREPARED FOR � o M c .JEAN HAR W I CK ;o SCALE 1 20 APR I L 13. 20 I S REVISED: MAY l I . 2015 STEPHEN A- HAAS ENGINEERING, INC P. O. B o x 16 > -� South D4annis MA 02660 / %�I/�;I~ ( SOB) 362-8132 JOB NO: 15-006 I i LEGEND ® CB CONCRETE BOUND -W WATER L l NE O �YDRANT G GAS L INE OHW- COVER HEAD WIRES -# 9L I GHT POST -f- UNDERGROUND ELECTRIC LINE -T - UNDERGROUND TELEPHONE LINE - CTV- UNDERGROUND CABLEV 1 S I ON LINE + 40.4 SPOT ELEVATION 40....... EXISTING CONTOUR ........ 40 )PROPOSED CONTOUR JOHN N Z. DEMAREST,JR o No. 36859_, •may GENERAL NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM I S ASSUMED. FOR BENCH MARKS SET. SEE S I TE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D - BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL "OIG -SAFE". 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING LEACH PIT TO BE PUMPED DRY AND BACKFILLED. 9. ALL UNSUITABLE MATERIAL (FILL. LOAMY SAND ONLY) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. VARIANCES REOU I RED : TITLE 5. MAXIMUM FEASIBLE COMPL 1 ANCE SECTION 15.211:(/) MINIMUM SETBACK DISTANCES 20' IS REQUIRED BETWEEN THE SAS AND THE FOUNDATION. 16' I S PROVIDED. A 4' VAR I ANCE I S REQUESTED. TOWN OF YARMOUTH SUBSURFACE SEWAGE DISPOSAL REGULATIONS REGULATION 3.7: DISTANCES & LOCATION OF DISPOSAL FACILITIES l00' IS REQUIRED BETWEEN THE SAS AND A WETLAND. 84' IS PROVIDED. A 16' VARIANCE IS REQUESTED. S EP T l C SYS TEM Di7S l GN 3 LEX I NOTON LANE. MAP 1 / 0 . PARCEL OS YARMOUTHPOR T . MA. G� PREPARED FOR � o M c .JEAN HAR W I CK ;o SCALE 1 20 APR I L 13. 20 I S REVISED: MAY l I . 2015 STEPHEN A- HAAS ENGINEERING, INC P. O. B o x 16 > -� South D4annis MA 02660 / %�I/�;I~ ( SOB) 362-8132 JOB NO: 15-006 I