Loading...
HomeMy WebLinkAboutEngineered Plans - 2015s 4 CA PT 100.08 100.10 CHASE ROAD 100,14 edge of pavement 100.78 ---_`1�`---� 101.11-Irp - r S 12',34'10" E 100.00' 101.78��- LA�1P.-- - 102.50 x. 10233 Qr. 0 - 0..;1,02 73 103,29 --i-03�c8 �( x GAMAE •` . b . + 101.64 x / ,..,. 103,00 103. 6 02,98 + 103, 1 t PORCH /EXISTING j W HOUSE(J100) I +`1`0, GARAGE T. O. F. =104.34-+ 102.66 /NV.(OU7)=101.84 \°i., Z shr. COND A bh 103.50 ° 0 102. 9 EXISTING CESSPOOL x TO BE REMOVED 101.98 °a° N x 10 2,STP 10 2 'f) + 103,44 / a 104,10 � 103.36 EXISTING CESSPOOL SHRUBS ` TO BE PUMPED, FILLED N 0 W/SAND & ABANDONED 10329 0 103, PATIO v ,i If LOT 159 loQ x� �t P MBL 78-55 PROP _s:a 103.04 x 12,000 ±SF 10297 r_.C__1�6.5'---103.15 100.00' 10245 S 12'34' 10" E x 102.74 I"- 0 L N r tA- PB 192,pG 129 BENCHMARK OUTSIDE COR./CONC PAD EL. =103.52 PROPOSED SEPTIC TANK EXISTING CESSPOOL TO BE PUMPED, FILLED W/SAND & ABANDONE T L. --9-7-- EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE _W -EXISTING WATER SERVICE _G -EXISTING GAS SERVICE - &A VJ- OVERHEAD WIRES TEST PIT Rella, 34 Concord Street, Englewood, BENCHMARK OWNER OF RECORD LEGEND Yarmouth Health Department _ . -APPROVED ame PETE Ni . JTl'>'� P -4 -- Date Date Capt Small Rd N Q � 9 LOCUS v x 0 rt N Z ;a a a Capt Besse Rd m o 0 a Capt Lothrop Rd LOCUS MAP NOT TO SCALE GENERAL NOTES: ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2• ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION, 7, WATER SUPPLY PROVIDED BY TOWN WATER SERVICE, 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9, ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN 15. CONTRACTOR SHALL VERIFY THE ALL SEWAGE FLOW IS CONNECTED TO THE PROPOSED SEPTIC SYSTEM. PROPOSED SEPTIC SYSTEM UPGRADE PLAN 100 CAPT CHASE ROAD, SOUTH YARMOUTH, MA 103,2 Prepared for: Dianne Rella, 34 Concord Street, Englewood, NJ 07631 OWNER OF RECORD Engineering by: Surveying by: SCALE DRAWN JOB. NO. RELLA, MARY K TRS RELLA, DIANNE M TRS Engineering Works, Inc. JC Engineering, Inc. 1 "=20' P.T.M. 163-15 4 CONCORD 54 CONCORD STREET S EET 12 West Crossfield Road Forestdole, MA 02644 2854 Cranberry Hwy. E.Warehann, MA 02538 DATE CHECKED SHEET N0. (508) 477-5313 (508) 273-0377 7/24/15 P.T.M. 1 Of 2 SEPTIC TANK NOTE: TO PREVENT BREAKOUT, FINAL GRADE INSTALL RISERS & COVERS OVER INLET & SHALL NOT BE AT, OR BELOW, EL.=101.0 OUTLET AND SET TO 6" OF FINISH GRADE PROPOSED D-BOX FOR A DISTANCE OF 15' FROM THE EDGE EXISTING - 104.341 OF THE PROPOSED S.A.S. O ` INSTALL RISER &COVER PROPOSED S.A.S. T.O.F SET TO 6" OF GRADE INSTALL RISER & COVER OVER EACH CHAMBER AND SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT INV.(OUT)=101.84 F.G. EL.=103.51 ///- F.G. EL.=103.51F.G. EL.=103.0± F.G. EL.=103.0± bh 3'(max.) ,L = 8' ® SCH4 (MIN.) ®S=19' (MIN.) L - 5' 4'SCH40 PVC _ 0,S=1% (MIN.) O 4'SCH40 PVC 4'SCH40 PVC 2" LAYER OF 1/8" TO 1/2" to"I DOUBLE WASHED STONE Dv r j INV.=101.30 as" LIQUID 14" e" ®a® ®®® (OR APPROVED FILTER FABRIC) �0, ��`• LEVEL ADD PROPOSED -'3/4" TO 1-1/2" DOUBLE GAS BAFFLE INV.=100.97 INV.=100.70 4' 5.2' 4' WASHED STONE C� INV.=101.05 � EFFECTIVE WIDTH = 12.8' W 3 OUTLETS INV.= 100.60 PROPOSED SEPTIC TANK 1-500 GALLON ON t EACHING CHAMBER ROP. � p0 CONNECT TO EXISTING SUITABLE SEWER PIPES SURROUNDED WITH STONE AS SHOWN i S.A.S. i c� AT HOUSE, AT OR ABOVE, INV.=101,5 H-10 RATED ____1 NOTES: TOP CONC. ELEV.=101.4± 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE BREAKOUT ELEV.=101.1 SEPTIC LAYOUT INVERTS, PRIOR TO INSTALLATION. INV. ELEV.=100.60 moons ®000010 2) SEPTIC TANK & D-BOX SHALL BE SET LEVEL AND BOTTOM ELEV.= 98.60 TRUE TO GRADE ON A MECHANICALLY COMPACTED 4' 8.5' 4' SIX INCH CRUSHED STONE BASE, AS SPECIFIED 4' OF NATURALLY OCCURRING IN 310 CMR 15,221(2). PERVIOUS MATERIAL EFFECTIVE LENGTH 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 5' (MIN.) ABOVE G.W. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE ADJ. G.W., EL.=93.6 r LEACHING SYSTEM $ .TII�N ® ® ® ® 0 AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. � ® Ea E3 E2 5Z� SEPTIC SYSTEM PROFILE N ; ® ® ® ®®® 00 33" Z Eil E3 a E3 Ea ®��®®®®®®®® SOIL LOG DATE: JUNE 25, 2015 102" DESIGN CRITERIA SOIL EVALUATOR: PETER McENTEE PE(SE#1542) WITNESS: AMY VON HONE R.S. HEALTH AGENT 4" KNOCKOUT NUMBER OF BEDROOMS: 2 BEDROOMS ELEV. TP DEPTH 20" DIA. COVER SOIL TEXTURAL CLASS: CLASS I (EFFLUENT LOADING RATE=0.74 GPD/SF) 103.0 A 0 4 KNOCKOUT/ DESIGN PERCOLATION RATE: <2 MIN/IN LOAMY SAND 4" KNOCKOUT 58" DAILY FLOW: 220 GPD 102.3 10YR 4/2 8" DESIGN FLOW: 220 GPD B. 0 GARBAGE GRINDER: NO-not allowed with design 4" KNOCKOUT LOAMY SAND LEACHING AREA REQUIRED: (220 GPD) = 297.3 SF 10YR 5/8 .74 GPD/SF PERC 500 GALLON CAPACITY, H-10 LOADING PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY 16"/34" CHAMBERS PROPOSED D-BOX: 1 INLET, 3 OUTLET (MINIMUM), H-10 RATED 100.0 36" C N.T.S. USE 1-500 GALLON LEACHING CHAMBER SURROUNDED M-F SAND WITH 3/4" t0 1-1 /2" DOUBLE WASHED STONE-ALL SIDES 2.5Y 5/3 PROPOSED SEPTIC SYSTEM UPGRADE PLAN SIDEWALL AREA: 2(12.8' + 16.5') x 2 = 117.2 SF 93.6 ADJ. G.W. _ 100 CAPT CHASE ROAD, SOUTH YARMOUTH, MA BOTTOM AREA: 12.8' x 16.5' = 211,2 SF 92.5 STG. G.W. = 127" Prepared for: Dianne Rella, 34 Concord Street, Englewood, NJ 07631 TOTAL AREA: ........328.4 SF .............. 92.2 130 Engineering by: Surveying by: SCALE DRAWN JOB. N0. DESIGN FLOW PROVIDED: 0.74 GPD/SF(328.4 SF) = 243.0 GPD STANDING G.W. AT EL.=82.5, INDEX WELL A1W-230, ZONE B Engineering Works, Inc. JC Engineering, Inc. 12 P.T.M. 163-15 WATER LEVEL=22.1 (JUNE2015), ADJUSTMENT=1.1', ESTIMATED HIGH G.W., EL.=93.3 12 West Crossfield Road 2854 Cranberry Hwy. Forestdole, MA 02644 E.Woreham, MA 02538 DATE CHECKED SHEET NO. PERC RATE 2 MIN IN. 'B C" HORIZONS (508) 477-5313 1 (508) 273-0377 7/24/15 P.T.M. 2 Of 2