Loading...
HomeMy WebLinkAboutEngineered Plan - 2002PROFILE OF PROPOSED SYSTEM {o _ G TOP OF FOUNDATION: CAPT. SMAIL ROAD — SEPTIC TANK — "D"— BOX — I LOCUS 22'f 30.5' CAPT. LOTMROP ROAD O 2 OF 1/8" TO 1-1/2" y ELEV. WASHED STONE o PROVIDE RISER & COVER TO WITHIN 6" OF FINAL PROVIDE RISER & COVER PROVIDE RISER &COVER GRADE TO WITHIN 6" OF FINAL GRADE GRADE IN 6" OF FINAL 3' MAX. COVER 9" MIN. COVER OUT— I 3' MAX. COVER 1 IN OUTS j 9" MIN. COVER 27.9't r, LIQUID LEVEL jjjj IN ouT-- LOCUS MAP 1"= 1500' ELEV. 26.50. 26.25' rFT PROPOSED � .-^. o 0 0 0 0 0' o 0 0 0 o O o o ELEV. 1500 GALLON ELEV. 26.00 , O o 0 0 0 0 0 0 0 = o o I= o SEPTIC TANK ELEV. G 25.83' .' :. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ' ELEV. ,: C:3 O I= O O I= O O O O O O O. O •�.:. •.: INLET TEE OUTLET TEE �. (10" MIN.) (14" MIN.) PROVIDE 6" COMPACTED PROVIDE _ CRUSHED STONE BENEATH 3O Xi 1O X 2 GAS BAFFLE DISTRIBUTION BOX } BOTTOM OF SYSTEM n415_ ✓ ,. , .� t .', /INVERT INTO CHAMBER ELEV.=23.3' ELEV.-25.5' PROVIDE 6" COMPACTED CRUSHED STONE BENEATH j SEPTIC TANK I I LOT 53 }} i •\ \2p.0�1 TEST HOLE LOG DESIGN: 3 BEDROOM DESIGN PROPOSED 1500 v GALLON SEPTIC TEST BY CHRISTOPHER S. WICKSON S.E. AMY VON HONE ! TANK PROPOSED 3 -OUTLET PERC RATE: < 2 MIN/IN. D I STP - I BUT I ON BOX EAST CAPE ENGINEERING, INC. YARMOUTH HEALTH DEPARTMENT TEST DATE 10/24/02 FLOW RATE: 110 GAL./BEDROOM (3) =330 G/D �\ I L07 52 SEPTIC TANK: (330)2=660 G/D �.� EXISTING CESSPOOLS T.H. #1 (ELEV.) 12/000± Sq, Ft. TO BE ABANDONED t. 0.00' 29.0 REQ'D SEPTIC TANK SIZE: USE 1500 GALLON TO/A, p,RA� FILLED WITH SAND LOAMY SAND . 28.2' LOAMY SAND LEACH FACILITY: ` • �^ ... "i'' •,-..,.: • '. OVASL� -1.67 ..,"•: ; 27.3' af, ' " ':. •. - •:• . �N� SIDEWALL: 2(30+10)(2)= 160S.F.(0.74)= 118 G/D 29.0' 1 pR! Z BOTTOM: (30)(10)= 300S.F.(0.74)= 222 G/D :... ` `r,... �.°`. __.'''.- x 0 0 ;} TOTAL: 460S.F. 340 G/D ty �a ro LOT 31 G • • MEDIUM/FINE SAND USE: 500 GALLON LEACHING DRYWELLS WITH 3/4" TO i x15T �NGV� 3x �pR` ' ' MSN • l�l 1-1/2" DOUBLE WASHED STONE TO EFFECTIVEU5� 0 y' SIZE 30 X 10 X 2'. O 1 W SERV x-10 70 EXISTING SPOT 2a 5 ELEVATION :.• • ALTERNATE- USE (B'X4'X1') LEACHING CHAMBERSK 29.0' Ch (TYP. WITH 3/4" TO 1-1/2" DOUBLE WASHED STONE TO NG�r1A �t x 18.0' EFFECTIVE SIZE 30' X 10' X 2' �E • X30 , 21 - -'' ALTERNATE- USE INFILTRATOR LEACHING CHAMBERS NO WATER ENCOUNTERED WITH 3/4" TO 1-1/2" DOUBLE WASHED STONE TO ; \ ' EFFECTIVE SIZE 30' X 10' X 2'.-'30- PROPOSED 30'x 10'x2' x"' \ 120 '0O SOIL ABSORPTION 3, SYSTEM _ I _ Z LOT 51 i N OF, Ss' NOTES:�° TIMOTHY J. yam BRADY 1. DATUM MSL ± TAKEN FROM DENNIS QUADRANGLE MAP CIVIL v76s N , I L 0 IR �% E D � + �o 2. MUNICIPAL WATER IS AVAILABLE -\\A OF a q DEC�.o 3. PIPE PITCH: 1/4" " PER FOOT MINIMUM A_ - TIM Tle-A s TWO T Y �yG C 9 2052 4. DESIGN LOADING FOR ALL PRE—CAST UNITS: AASHTO—H-10-44, H-20-44 WHERE VEHICLE ,.- o g{ J. rn LOADS ARE ANTICIPATED OR WHEN SUBJECT TO 4 FT. OR MORE OF COVER. _ , ",; BRAD; �Z `� f t i Al I SITE PLAN 77 L� _ - 5. MINIMUM GROUND COVER OVER ALL SEWAGE LEACHING FACILITIES: (0.75) FT. 0 2�i dZ —SEWAGE SYSTEM UPGRADE— 6. THIS DESIGN DOES NOT PROVIDE FOR THE INSTALLATION OF GARBAGE GRINDERS. o 7. ALL UNSUITABLE MATERIAL WITHIN 5 FT. IN ALL DIRECTIONS FROM THE LEACHING ^s,� E�= a osuav o¢ DATE. I Locus: 91 CAPTAIN YORK ROAD FACILITY SHALL BE REMOVED & REPLACED WITH CLEAN, MEDIUM SAND. oNrwve 8. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH COMM. OF MASS. STATE j East Capp Engineering, Inc. S. YARMOUTH, MA ENVIRONMENTAL CODE 'TITLE 5.CIVIL ENGINEERS REF; ASSESSOR'S MAP 78, PARCEL 98 9.' CONTRACTOR TO NOTIFY DIG—SAFE PRIOR TO. CONSTRUCTION. (1=888—DIG-SAFE)LAND SURVEYORS i 10. NO KNOWN WELLS .WITHIN 100' OF PROPOSED SOIL ABSORPTION SYSTEM. - BOARD of HEALTH # 44 Route 28, Orleans, Mass. PREPARED FOR: BARBARA DUNBAR 11. THIS SITE PLAN IS INTENDED FOR SEWAGE SYSTEM DESIGN PURPOSES ONLY. UNDER NOAPPROVE MA (508) 255-7120 �.G '7� �7— L YARMOUTH CIRCUMSTANCES ARE BEARINGS, DISTANCES, OR FEATURES SHOWN TO BE USED TO ESTABLISH PROPERTY LINES, SCALE: 1"=20' DATE: 10/25/02DWG-02145SPL 02-145