Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH � ��� � � / SEWAGE PLAN REVI�W CHECKLIST �'�I/l� l ���_G� � Location: A.M._�� Lot �� ZoneofContribution: In�Out_ Acreage��/ � Commercial: Residential:� �s��: a9 � Village:��i Floor Plan: �/ #Bedrooms:� Owner: �j,,2^�.�Of �f.GGG�' Installer: l�1�`'� ���!'� Address: � Phone: � � � Phone: Builder: Engincer: ��////�PG� � Address: Phone: - 1- ' Z L Phone: �� %� ✓y.� 5 -�e<�,.�t e�-�-G"�� --� �/� '� �� >' ��i �. �� Fz21 9`P Gl�°Zff� N/A YES NO 1.R uued#of copies received 2. Date of soils e�cam and ercolation test not older than 2 ears l� 3. 4-5 ft of natural occurrin ervious material, above wat�table �� 4.Foundation 2 ft above hi int of road H.P.: Fnd: �ar.:' 5. Water line 10 ft from s tic com onents Vaz.: �1 6.Benchmark indicated and shown-NGVD if near wetlands 7. S tic tank minimum 10 ft from foundation, deck Var.: ✓ 8. I.eachin minimum 20 ft fiill, 15 ft crawl, 10 ft slab Var.: 9.I.eachin minimum 100 ft from wetlands Vaz.: 10. Leachin minimum 150 ft from drinkin we1U25 ft irri tion well Vaz.: ✓� 11. Tank/leachin minnnum 10 ft from line Vaz.: C/ 12. S stem meets alt other setback r uirements Vaz.: 13. Uses ad'ustment for maximum hi undwater Vaz.: ✓/ 14. Leachin set 4-5 lt above ad'.water or bottom of test hole Vaz.: 15. S stem not in t or subsoil(A,B horizons or 5' removal l� 16.Pro sed contours aze suitable C� 17. S stem meets sl e r irements-min. 1/8", '/d' ef _ �� � 18. S stem meets breakout uirements C liner: Wall: ? 19. S ecified tee sizes are ro , gas baffle on outlet tee 20. Sewa e is und� 10,000 for arcel ✓ .21.No ba e dis osal 22. S stem ad uatel sized far its intended use 23.Minimum 6"stone or wm acted below tank and dbox �/ 24.Manhole covers within 6"of de, um chamber cover to ade 25.Ins ection ort on lastic chambers/leach field 26. Electrical ermit for um chamber/S arate meter for du lexes 27.Pu stem-2"line,w hole,check valve,tee in dbox, um size �� 28. S ric tank/ um chamber to be factory wat roofed 29. Vent rovided if leachin below 3 feet,und�drivewa / arkin 30. Buoyancy calculations for tank/ u chamber 31. En ' eer to ins ect aud cert soils wall: commercial: `_ 32. En 'neer/Re 'stered Sanitarian and Land Surv or stam s/si ture _� 33. H-201oadin is sub'ect to vehiculaz haiiic, oundwater �� 34.Title V A lication and ermit fee, installer si ture ✓ 35.Foundation footin min. 2 feet above ad'usted ound water for new house 36.Deed Restriction r ired max. #bedrooms: ma�c. flow: 37. Check azea lots for oundwater/Label oundwater in Assessor's Map Plan reviewed by: � ��o; �