Loading...
HomeMy WebLinkAboutEngineered Plan - 2015103.6 + 102.1 ACCESS COVERS MUST BE WITHIN 6" OF FINISH GRADE \FIRST 2' TO BE LEVEL -7 9' MINIMUM. 3' MAXIMUM COVER MIN 2' OF PEASTONE OR FILTER FABRIC 3/4" - 1 1/2- DIA. 101.3 U2 T � 100.75 " 100.2 + f 2 • �' DOUBLE WASHED STONE 10/.0 GAS �/ 100.37 c 100.0 ,I ` III I ��( 98.0 BAFFLE - 3 OUTLET 3-500 GAL LEACHING CHAMBERS D -BOX W14' STONE AROUND. 12.8'r x 33.5'1 x 2'd 1500 GAL H-20 SEPTIC TANK 6" CRUSHED STONE OR COMPACTED BASE PROFILE:NOT TO SCALE 11 I S 83° 14 -30 "E + 102.7 120.00 I _- I I \ 3-500 GALLON D LEACHING CHAMBERS ..........::........ 1 _ ; �_, • W/4' STONE AROUND D -BOX '/ , - - - - I � I SM.# CORNER BH iy \ I /N \ ELL103.60 \ /03.5 \ 1 1500 GALLON �� O / - SL'PT1 C TANK GARAGE \ \ Q>/ \ 1.03.3 O ' CESSPOOLS II i/. KITCHEN 03.0 / 14 TREE I D CK 1 DINING I ROOM G I BEDROOM BEDROOM BATH BATH /STOCKA I ,oma 0;0 N 83" I4 '30 "W I n /N f f /% A/ A r'1 BEDROOM BEDROOM BATH SECOND FLOOR PLAN + 02. LOT 3IA `\ 12.960± S.F. 1 \ / I I 1 I I 1 I I l I I I i I I I i I i 1 I I I I�I r 1 1 1�1 1 1 1 1 1 I I 1 I 1 / \ INVERT ELEVATIONS: INVERT AT BUILDING: 101.3 INVERT IN SEPTIC TANK: 10/.0 INVERT OUT SEPTIC TANK: 100.75 INVERT IN DIST. BOX: 100.37 INVERT OUT DIST. BOX: 100.2 ;INVERT IN LEACH CHAMBER: 100.0 ,BOTTOM OF LEACH CHAMBER: 98.0 `ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE #l: 92.5 DESIGN CRITERIA: DESIGN FLOW: 4 BEDROOMS AT 1/0 G.P.D. PER BEDROOM EQUALS 440 G.P.O. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 440 G.P.D. X 20OX - 880 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE ( 5 MIN/INCH SOIL TEXTURAL CLASS - l EFFLUENT LOADING RATE - 0.74 GPD/SF 440 GPD / 0.74 GPD/SF - 595 S.F. REQUIRED PROVIDED: 3-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-614 S.F. 614 S.F. x 0.74 - 454 G.P.D. SOIL TEST PIT DA TA INDICATES V INDICATES PERCOLATION = OBSERVED TEST GROUNDWATER f LEGEND 12 CB TP #1 -W 0" HORIZON TEXTURE COLOR 102.8 -G GAS L 1 NE LOAMY IOYR A OVER HEAD WIRES # SAND 3/2 -E- 6" -------------------- 102.3 - CTV- B LOAMY IOYR + 40.4 SPOT ELEVATION SAND 5/4 EXISTING CONTOUR 18" -------- /O/.j Cl MED I OM I 0 YR M SAND 6/4 i 48" 124 " d NO WA TER 92.5 l i DA TE: JUL Y 22, 2015 TEST BY: STEPHEN HAAS Wl MESSED BY: AMY VONHONE PERC RATE: ( 2 MIN/INCH GENERAL NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DA TUM IS ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MA TER I AL S AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN J' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE 15 MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 8. EXISTING CESSPOOLS TO BE PUMPED DRY AND BACKFILLED. 9. INVERT AT THE DWELLING TO BE RELOCATED TO THE LOCATION AND ELEVATION SHOWN. TETli f. VIA,,�e��R P'0 "372 SEPTIC SYS TEM DESIGN I j Yarmouth Health Department S 1 G O R D O N LANE . MAP / 14. PARCEL 8 O �A .? VEE tae Date YA R M O U T H P O R T. MA . CB/SEAL FND 7_4,_42T-4 x_-TIT,,,i PREPARED AOR UP 802-6 LEGEND 12 CB CONCRETE BOUND -W rA TER L I NE O HYDRANT -G GAS L 1 NE OHW- OVER HEAD WIRES # , IGHT POST -E- UNDERGROUND ELECTRIC LINE -T- UNDERGROUND TELEPHONE LINE - CTV- UNDERGROUND CABLEVISION LINE + 40.4 SPOT ELEVATION _-"40 ------- EXISTING CONTOUR 40 PROPOSED CONTOUR PAUL E7AR/ E S HED WAY /uIARSTOIVS M / LLS MA 02648 O WATERS - SCAL E l a 20' AUGUST 13 2015 STEPHEN A. HAAS \1� ENGINEERING, South Denn i ( 508) INC P . O. Box 16 s MA 02660 362-8132 JOB NO: 15-032