HomeMy WebLinkAboutDecision 4311 - Sewage PlanV !i SEPTIC SYSTEM PROFILE COVER TO WITHIN TOF 101.33 BM ASSUMED _/_6" OF FINISHED GRADE COVER TO WITHIN 6' OF FINISHED GRADE 7 rK cOTEB I INLET TEE BAFFLE FINISH GRADE 99.6 EL ALL � TO BE TO MATCH EXISTING a• BCB is PVC PPE TO BE LEYM TOP ®98.0 FW Y WT OF B -BOX 14' �98.I9 MINIMUM 2' PEASTONE OR GAS BAFFLE 97.65 97.49 97.3- GEOTEXTILE FABRIC. uBOTTOM BOX M ® 95.3 ��- 6' COMPACT STONE 5- 500 GALLON H-10 O YWELLS WASHED 1500 GALLON H-10• OR COMPACTED BASE WITH 3AND 1/2' OF DOUBLE WASHED STONE MONO SEPTIC TANK 4' ON ENDS AND 2' BETWEEN DRYWELLS AND 4' ON SIDES 5.66' at' X 16.5' 89.64 EL BOTTOM OF TEST HOLE 98.54 X 100,31 PK/SET I .�99.41 '�e9.42 BenCFBeak Bet 0 v p1991�48 .53 Left cor. brick step loo E1..100.10 lA�eulned) of a/e 99.14 u .81 99.21 Pa�Pd 100.01 t g,43 n Dr l 99 44 k�0 ICO. 3 ) x 100,10 Porch 99.88 769 TOF61OL33 (rrBW 9r1cIJ 100.24 BARN - 1 10, LIPM/2 Rss.-m ' 41 1 6' � �-� 89.21 1 ]!' , 1 �-- 9. 9Al tP/FNID 99.63 Z 9�1' " wire 99.83 { 4, 99.80 Lot 1 14$46./- B.F. 0.33N- AC. Map 60 Pacel 223 `d x E l ar.1 calms � De S 99.61 % lyl 1L � GiPvJ1- .5! 99.64 ,bl � 21 99.68\ 2.3 \ 4�. r' 99.69 V\ O -A t Abut. 99.6 1 99.31 HBe. 99.'14 , IG/G1.1D E 99: r 194 rIaOR t Ln to\kll eProposed 25'x32'Ban and Ari. on 5L41► 82 N_e_W (>/Z6pOOSAC>A) 0&%t ,NAL �up O 1.9 NW � : %1 -1L - 1 10, LIPM/2 Rss.-m ' 41 1 6' � �-� 89.21 1 ]!' , 1 �-- 9. 9Al tP/FNID " wire 99.83 99.90 1O0 99.80 TArl f o ANNERRY m-11 " WARNER Na. 38721 a w.1t tnc , 0 TEST HOLE LOG TEST HOLE ! 1 0' 99.6 EL A LOAMY SAND IOYR 2/2 98.85 FT BW LOAMY SAND 10YR 5/4 22' 97.77 EL FINE SAND C 2.5Y 6/6 138' 88.15 EL WATER NOT ENCOUNTERED Z m17 I- loop, BEDkcodn - BEDROOM sewwtr li At_L 1'ZDDM D ED RDOLM THIRD-FIoOR - ATTLC, I"OFmAs'? yG f ANNY $ WARNER No. 38721 ?/d7 Scale: N20' PK.00 O' �' �' 60' `�-�- Lrs t3 07 B DATE: 5-10-07 TEST BY: MIKE O'LOUGHUN WITNESS AMY VON HONE PERC RATE: < 2 MIN _a TEST HOLE 4 1 0'1 99.6 EL �� A V.F.LOAMY SAND 1OYR 4/9 96.6 FL BW V.F.LOAMY SAND - 10YR 5/6 24_ 97.6 EL eY BOTTW OF PERK 9618 M V. F. SAND C 2.5Y 6/6 120' 1 1 89.64 EL WATER NOT ENCOUNTERED GENERAL NOTES 1. CONTRACTOR TO BE RESPONSIBLE FOR THE LOCATION OF ALL UTIUTIES, ABOVE 8c UNDERGROUND, PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 2. SEPTIC SYSTEM IS TO BE INSTALLED IN COMPLIANCE WITH 310 CMR 15.00:TITLE V. 3. ENGINEER TO INSPECT & CERTIFY OVER -DIG, WHEN REQUIRED BY PLAN, AND FINAL INSPECTION BEFORE BACKFILL 4. CONTRACTOR TO PROVIDE 48 HOUR NOTICE FOR ANY REQUIRED INSPECTIONS. 5. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE DISPOSAL 6. THE TOP OF ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. 7. IF SOILS ARE FOUND UNSUITABLE OR DIFFERING FROM THOSE FOUND IN SOIL LOG CONTACT, THE BOARD OF HEALTH. 8. IF AN OVERDIG IS REQUIRED IN BELOW PLAN OR IF UNSUITABLE SOIL,FQUNO,IN _RESERVE .AREA, .CLEAN' GRANUTAR SAND MEETING 310 CMR 15.255(3) SHOuW QBE USED AS FILL MATERIAL, 5" AROUND AND UNDER S.A.S.. NO;S 1. PUMP OUT AND FILL (2) EXISTING LEACHING STRUCTURES. 2. FLOOR PLAN PROVIDED BY OWNER, NOT TO SCALE. DESIGN DATA DAILY FLOW: (6) BEDROOMS X 110 GPD a 660 GPD SEPTIC TANK: 660 GPD X 200% - 1200 GPD USE 1500 GALLON PRECAST MONO H-10 SEPTIC TANK DISTRIBUTION BOX: �.. USE: DB -5 H-10 SOIL ABSORPTION SYSTEM: USE: (5) 500 GALLON H-20 MONO DRYWELLS WITH DOUBLE WASHED STONE V ON SIDES AND 2' BETWEEN DRYWELLS AND 4' ON ENDS. CAPACITY: - SIDEWALL AREA: 115' X 2' X 0.74 - 170.20 GPD BOTTOM AREA: 41' X 16.5' X 0.74 - 500.61 GPD TOTAL AREA: 670.81 GPD HEALTH AGENT APPROVAL SEWAGE PLAN LOCATION: 269 OLD MAIN STREET SOUTH YARMOUTH, M PREPARED FOR: ROBERT NEWELL SCALE: 1' - 20' - DATE 5/16/07 .IDB NUMBER: 07-006 txEvroww SHEET NUMBER: 1 J. O'LOUGHLIN INC. 714 MAIN STREET, YARMOUTH PORT, MA 026 (508) 362-4942 . DATE Br. MARYBETH MCKENZIE REGISTERED SANITARIAN 4131