Loading...
HomeMy WebLinkAboutDecision 4308T E 36 9' SEPTIC. PROFILE �'PVgT xoLE ioc's ---- -- .ACCESS COVER TO WITHIN 6. OF FIN. GRADE - (NOT TO SCALE) I 36X0 ACCESS COVER ('.VATERnGHT) TO / 36x0WITHIN 6. OF FIN. GRADE MINIMUbt .75' OF COVER OVER PRECAST / _ - 2% SLOPE REQUIRED OVER SYSTE. RUN PIPE LEVEL , 2' DOUBLE WASHED PEASTC FOR FIRST 2' (EXIST.) — PROPOSED 1500 _ GALLON SEPTIC hll -- , /533.01 1,4NK (H- 10 -- -- - - -- J 32.64 32.47' 32.43' ( 3 %SLOPE) - �6' CRUSHED STONE OR MECHANICAL 1 COMPACTION. (15.221 [21) —� 4' 8goo 8800 DEPTH OF FLOW 4 (_1 y, SLOPE) - (_..! _% SLOPE) - — 2 3/4' TO 1. 1/2' DC TEE SIZES; INLET DEPTH = 10`x; OUTLET DEPTH = 19" _ FOUNDATION— 62' = SEP I Il; TANK — 11' --- D' BOX 6' (MAX) IRRIGATION WELL CO / SHED FeNSE"�,,\ —INVERT APPEARS TO BE BELOW SLAB 1 If 3�o r� ELEVATION. ADJUST- SEPTIC TANK 9� 4� ELEVATION AS/IF NECESSARY TO PROVIDE � GRAVITY FLOW Lor 4 \\ 'r I 28,963 sq.ft. 0.66 Acres El \ \�C,t r—\ S geACf UTIL. POLE36, \\ TH Cp ..284.4 A' 0 tAT NCHMARK: TOP CONC. BOUND ELEVATION 36.26'eNCF 36 ���---� G /O = JOB## 98-157 ENGINEER: DAN OJALA, SE a 36x0 WITNESS:.. ____ COLLEEN PELLE. E 3' MAX. DATE:_____ 5/6/98 - -- --- rE _ <2 MIN./INCP PERC. P-, 33x0 TOP 07 F ERO. AT 48" - CLASS SOILS P# _ N/A - - — 4' c�Fi o o p ELEV. aLE WASHED STONE p" 35.8' 0" I 30.43' — c, ---� LOAMY ;AND 10 YR 3!2 _EAOHING 5 — - ACILITY B 1 ASSESS' -,RS MAP 61 PARCEL S4 LOAM ' CURREt T ZONING DISTRICT: 5.63' SAND SETBACKS: N/A (EXISTING DWELLING) 10 YR 5/6 FRONT = 34" -- ---' 32.91 SIDE= C1 I .FINE/I. ED I 24.8' + SAN!) 2.5 YR 7/4 I FLOOD r:ONE: C I 132" 24.8' �- I ' /' NO WATER ENCCU JTERED NOTES: NOT tiLLOwED SEPTIC DESIGN: (�nRSAGE DISPOSER Is _ _ ) � DATUM IS ASSUMED FROM DENNIS QUAD MAP Jr -SIGN FLL),C 4— BEDROOMS (i l U GPD) _ ``' U GPD � • �+vii,irn;_ r,,ti cn I� _ - - -.. _,.. _ - r USE A4_40 GPD DESIGN FLOW 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. SEPTIC TANK: 440 GPD (_2 ) = 880 GALLONS --- 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. USE A 1500 GALLON SEPTIC TANK 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. S S/0 LEACHING: ENVIRONMENTAL CODE TITLE. V. SIDES: _A2K39.25 + 111]L2h' - 319_5 G?p 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE _74 —) - USED FOR LOT LINE STAKINl3. BOTTOM:__39.25 x 11 _ (,74) = 148- GPD 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. TOTAL: 631.8 S.F. 467.5 GPD 9, COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT USE 5 HIGH CAPACITY INFILTRATORS WITH i3" STONE INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. - UNDER SYSTEM AND 4' OF STONE ALL AROUND 10, CESSPOOLS TO BE PUMPED AND FILLED WITH CLEAN SAND OR REMOVED AS NECESSARY. LEGEND 1 i. SYSTEM IS NOT DESIGNED FOR VEHICLE LOADING 100.0 PROPOSED SPOT ELEVATION UPGRADE SITE AND SEWAGE PLAN 100x0 EXISTING SPOT ELEVATION =- 100 PROPOSED CONTOUR GF # 117 NORTH MAIN STREET — — 100 — — EXISTING CONTOUR III THE TOWN OF: (SOUTH) YARMOUTH FREPARED FOR: BORTOLOTTI/MISSIOS BOARD OF HEALTH �30 0 30 60 90 Feet M -A — APPROVED DATE SCALE: 1" = 30' DATE: MAY 21, 1998 aff rax roe ase -mw - down cape engineering, inc. CIVIL ENGINEERS �y A G LAARNE H. ND SURVEYORS = H oT : 0.V -A civ 939 main st. yarmouth, Ina 02675 rase N LAroniE. DATE