HomeMy WebLinkAboutDecision 3799 - Proposed Septic DesignTOP OF FOUNDATION ELEV. . 100.90 20 FT. MINIMUM FROM CELLAR SOIL TEST DATE OF SOIL TEST MAY 30 2002 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE OTHER 1/8" TO 1/2- CONCRETE CLEAN SAND SOIL TEST DONE BY � QE ILL ENGINEERING 10YR3/3 NO COVERS WITNESSED BY A.VO�iQNE INSPECTION PORT WASHED STONE LOAMY SAND 4' SCHEDULE 40 PVC PIPE MIN. PITCH 1/8" PER T. F OBSERVATION HOLE 1 ELEV.= 98.6 LOAM AND SEED OBSERVATION HOLE 2 ELEV._ 99.3 PERCOLATION RATE _<Y MfN./INCH AT __ 62 ,INCHES PERCOLATION RATE <_2 MIN / 2" LAYER OF DEPTH HORIZ .TEXTURE COLOR MOTT. OTHER 1/8" TO 1/2- 4.20 4" CAST IRON PIPE 10YR3/3 NO ROOTS 99,00 MAX. WASHED STONE LOAMY SAND (OR EQUAL) MINIMUM 58-144 C2 FINE SAND 22-60 Cl VENT 98.75 MIN. NOT REQUIRED - 10YR6/6 PITCH 1/4" PER FT. __M 60-120 C2 FINE SAND 2.5(7/4 _____ EXISTiNG'CONTOUR ----00---- -QZaO_ z FINAL CONTOUR SOIL TEST LOCATION FLOW LINE UTILITY POLE -0- ELEV. _ 98.70 10` 88 00 _ -TMIN. 1 LEV. a y ELEV. _98.10 LEVEL 9_8_00 6" SUMP 95_83_ °°° ° '' ° - ` _. a 10 _ 10 94.87_ e ° ELEV. _ _ '` - _ BAFFLE TELEV. DISTRIBUTION _ _ ° ooe LIQUID lDFPTH OUTLET ELEV. a °o° ° o°�ooeo oJlo goo ',oeo ole• o ELEV. = 93.50 __ 4 FEET TEE 14 INCHES (TO BEPLACEDON FIRM BASE) BOX -25m- S FEET A rccr 19 INCHES oa leiruco 1500 GALLON TO BE WATER TESTED IF MORE THAN ONE OUTLET B HIGH CAPACITY INFILTRATORS WITH 8,20 STONE IN AN DEPTH HORIZ .TEXTURE COLOR MOTT. OTHER 0-13 A LOAMY SAND 10YR3/3 NO ROOTS 13-22 B LOAMY SAND 10YR5/6 58-144 C2 FINE SAND 22-60 Cl MEDIUM SAND 10YR6/6 USGS PROBABLE WATER TABLE ELEV. _ __M 60-120 C2 FINE SAND 2.5(7/4 _____ EXISTiNG'CONTOUR ----00---- SEPTIC TANK (TO BE PLACED ON FIRM BASE) 11' X 48' X 2' TRENCH FORMATION WELL N/A NO WATER ENCOUNTERED AT __12Q_ ELEV. _ __ R8 6 LOAMY SAND 3/4" TO 1 1/2" CLEAN DOUBLE WASHED n SOIL ABSORPTION ZONE INDEX LOAMY SAND STONE FREE OF FINES '& SILT SYSTEM SAS ADJUST j Sl"EE75ER'GL�ERG 235 GREAT WESTERN ROAD 508- P. 0. BOX 713 399-3922 SOUTH DENNIS, MASS. 02660 58-144 C2 FINE SAND LEGEND: V� SEWAGE DISPOSAL SYSTEM PRO�TFILE USGS PROBABLE WATER TABLE ELEV. _ __M EXISTING SPOT ELEVATION 00,0 NOT TO SCALE / ) ELEV. _ OBSERVED WATER TABLE ( BOTTOM OF TEST EST HOLE ELEV. _ _____ EXISTiNG'CONTOUR ----00---- -QZaO_ FINAL SPOT ELEVATION 0 0 FINAL CONTOUR SOIL TEST LOCATION UTILITY POLE -0- TOWN WATER —WW CATCH BASIN �L*7 GAS LINE / - CLEAN OUT C I CESSPOOL C.P. Q i / eefv�nav" Tatar % / (ASY#IfDJ tGO.0 �\j� r N y ' f / 7Sr 2 0 k0 / .9 0 SOIL 1y o / 7ESr 1 / 107 AREA 9,1461 SF. j —N— . INCH IN C2 HOR17ON DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-15 A LOAMY SAND NO ROOTS 15-24 B LOAMY SAND 24-58 Cl MEDIUM SAND j Sl"EE75ER'GL�ERG 235 GREAT WESTERN ROAD 508- P. 0. BOX 713 399-3922 SOUTH DENNIS, MASS. 02660 58-144 C2 FINE SAND TIGHT WHITE SCALE 1' — 20 REV. MAR. 11, 2003 10B N0 5410-00: 1 - SAND (C2) NO WATER ENCOUNTERED AT _124•_ ELEV. DESIGN CALCULATIONS NUMBER OF BEDROOMS 3 DESIGN FOR 5 GARBAGE DISPOSAL UNIT _NO _ TOTAL ESTIMATED FLOW ( 110 GAL./BR./DAY X 5 SR.) S,SO_ GAL./DAY REQUIRED SEPTIC TANK CAPACITY 1140_ GAL. ACTUAL SIZE OF SEPTIC TANK 1500 GAL, SOIL CLASSIFICATION DESIGN PERCOLATION PERCOLATION RATE �_�MIN./IN. EFFLUENT LOADING RATE 4.74 GAL./DAY/S.F.LEACHING AREA 18400 SQ. FT. 11 X48+(59 X2X2) LEACHING CAPACITY (AREA X RATE) =,M GAL./DAY 764.00 X 0.74 RESERVE LEACHING CAPACITY M5' M GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN OF—YA3MQQlH____ RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. - 5. NO DETERMINATION HAS BEEN .MADE AS To COMPLIANCE .WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO 09TAIN SUCH DETERV!NATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL 'DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8 PARCEL IS IN FLOOD ZONE —O�_, 9. LOT IS SHOWN ON ASSESSORS MAP �S,2�RCE1 270 MAR 1 Z� 2003 TOWN OF YARMOUTH BOARD OF APPEALS APPROVED: BOARD OF HEALTH DATE AGENT 1p� 2� Lo��s ��`'°�, kav I" cA�r meq �0 PRO mac, �Ecr � Quo PROPOSED SEPTIC DESIGN FOR RAY SARACENO, JR. PRofcT LOC. 20 & 21(1/ ) 42 PROSPECT 'ST., W. YARMOUTH j Sl"EE75ER'GL�ERG 235 GREAT WESTERN ROAD 508- P. 0. BOX 713 399-3922 SOUTH DENNIS, MASS. 02660 DATE JUNE 3, 200211 SCALE 1' — 20 REV. MAR. 11, 2003 10B N0 5410-00: 1 LOCATION MAP REV.. SHEET 1 OF_17