Loading...
HomeMy WebLinkAboutEngineered Plans - 2015GENERAL NOTES 1. ALL PRECAST COMPONENTS TO BE H-10 RATED. ALL COMPONENTS WITH ANY ANTICIPATED VEHICULAR TRAFFIC TO BE H-20 RATED. 2. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OFA GARBAGE GRINDER. 3. MUNICIPAL WATER IS AVAILABLE. 4. ALL CONSTRUCTION TO CONFORM WITH 310 CMR 15.000 AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS. 5. INSTALLER/CONTRACTOR TO REVIEW & VERIFY ALL ELEVATIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO DESIGNER PRIOR TO CONSTRUCTION OR ASSUME ALL RESPONSIBILITYY, 6. INSTALLER/ CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SAFE WORK AREA, VERIFYING ALL UTILITIES AND NOTIFYING "DIG SAFE" (1-888-344-7233) 72 HOURS PRIOR TO CONSTRUCTION. Z ANY CHANGES TO OR DEVIATIONS FROM THIS PLAN MUST BE APPROVED IN WRITING BY FLAHERTY ENVIRONMENTAL SERVICES AND LOCAL BOARD OF HEALTH. 8. FINISH COVER OVER COMPONENTS IS NOT TO EXCEED 3' PER 310 CMR 15.000 UNLESS SHOWN PER PLAN. 9. ALL ABANDONED SEPTIC SYSTEM COMPONENTS TO BE PUMPED DRY AND FILLED WITH CLEAN SAND OR REMOVED AND REPLACED WITH CLEAN SAND. 10.ALL COMPONENTS TO BE PROVIDED WITH WATERTIGHT ACCESS PORTS WITHIN 6" OF FINISH GRADE. 11.ALL SEPTIC TANKS, DISTRIBUTION BOXES AND PIPING TO BE INSTALLED WATERTIGHT, 12. NO KNOWN WETLANDS OR WELLS WITHIN 100 FEET OF PROPOSED LEACHING. 13. THIS IS NOT A CERTIFIED PLOT PLAN AND UNDER NO CIRCUMSTANCES IS THIS PLAN TO BE USED FOR ZONING OR BUILDING PURPOSES. 14. LOT IS SHOWN AS ASSESSORS MAP 41 PARCEL 42. 15. LOCUS PROPERTY IS NOT LOCATED WITHIN AN AQUIFER PROTECTION DISTRICT (ZONE II). DESIGN CALCULATIONS SYSTEM DETAIL Flaherty Environmental Services P. 0. Box 81 Yarmouth Port, MA 02675 NUMBER OFACTUAL BEDROOMS 3 508.362.1657 GARBAGE DISPOSAL UNIT NO TOTAL ESTIMATED FLOW (I 10 GAL/BR/DAYX 3 BR) 330 GALADAY REQUIRED SEPTIC TANK CAPACITY 660 GAL. SIZE OF SEPTIC TANK 1000 GAL. (EXISTING) SOIL CLASSIFICATION 1 DESIGN PERCOLATION RATE <2 MIN.IINCH EFFLUENT LOADING RATE 0.74 GALADAYIF-P LEACHING AREA (2)x(25.01+12.839(2) = 151 SF 25.0' x 12.83' = 320 SF 471 SF 0.74 = 348 GPD USE (2) 500 GALLON CHAMBERS WITH 4'S TONE AS DIAGRAMMED INA 25.0'X 12.83'X2' CONFIGURATION RESERVE LEACHING CAPACITY NIA SOIL EVALUATION TEST HOLE #1 Evaluator. David D. Flaherty Jr., RS, REHS SE#2755 BOH Witness: Phil Renaud Date: September 9, 2015 TH-1 ELEV. 98.0' 0"- 10" I OWE LS f0 YR 2/2 10"- 38" 1 B LS 10YR 5/6 38"- 131" 1 C MS 2.5Y5/6 G.W. ELEV. NIA BOTTOM TH-1 ELEV. 8T. 1' (NTS) q4,� PERC EL. 94.0' 24 GALS. "AT 7" SITE AND SEWAGE PLAN ®t�� . FOR B & B EXCAVATION, INC./ l car* that on November 12, 2002, I have passed FREDERM G. BOYLE the examination approved by the Department of �� 23 PINE GROVE ROAD Environmental Protection and that the above analysis has been performed by me consistent with the �4 N s SOUTH YARMOUTH, MA required training, expertise, and experience described in 310 CMR 15.018(2)." p► r / % 1� PAGE20F2