HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
S 7 S 7 SEWAGE PLAN REVIEW CHECKLIST
Location: AM 10�o LOT_� Date of Subdivision Approval
Street /S /�/P�.S A.c� Zone of Contribution_ In � Out
Village , ��l'� � Commercial Residentiai �
Owner: GU//�/e/yi S�nv'e!�' Installer �G/LtO� ((a.
S� - ���- 3'r
,
BuIlder: Engineer �-Py/ .�[��l�
- 7�/- 5 �GL� �;
N/A YES NO
1. Required number of copi received. .�-�''�
2. Date of soils exam a d oercolation test not older than 2 years. ,
�. 4 feet of natw�allv occurring nervious material above water tabte(new conct�uction) .
4. Foundation 2 feet above hig}�,noint of fronting road for new construction. c �
5 Watec availability lettet from Water Denarrment for new construction /'
�z._Benchmark indicated and shown-NGVD if near wetl�n�3s ✓'
7 $uilding sewer does not exit center of house „�
8. Seutic tank a minimum of 10 feet from house and deck .�
2 Leachin� a minimum of 20 feet &om house and 10 feet from deck ��
10. Leachine a minimurrt of 100 feet from wetlands. ✓
11 Leac 'n� a ;nimnm of I50 feet from rinki � weilcl25 feet from irrigation wells ✓
12. System m�ets all oiher setl�ck_r_eauirements. ✓
13. Uses adjustment for maximum lri��roundwater. .�^
14. Leaching�_-�feet above adiusted water table or bottom of test pit. .�
]��ystem not in top or subsoil or 5 foot removal
1C. Protmsed contours are suitable.
17. System meets s requirements- mi2 1/8"_ 1/4" �referred. ,/
18 Svstem meets breakout reguirements peastone elevation carried out 15 feet �n�num
19. Soecified tee si�P aze �ocer gas b�fFle on outlet tee
20 Sewage flow under 10 000 gttd for nazcel ,� i
21 No g�ge disnosal
2�ystem adeauate�sized for its mtended use �
z3. Minunum 6" stone or mechanicauv c�acted below the t nk and d-box , i
24. Manhole coverc_within 6" of grade - sentic tank �py�p c1La_mber. , �
5. EI rical nermit for pump chamber ,f
�6 Pum�sv�tem- 2" line weep hole check valve sanitary+in d x a�a***+ on cen�te circuit ✓
7. Se t c tank a d vump chamber to be Factory watemroofed_ ✓
�. Vent orovided ' leac �n,g below 3 feet or under driveway�p rk; g, �
29.Eneineer to insRect and certifv • a,slav removal �
b. wall construction sched �IP �
: ommer �ai s ✓
�0, Enaineer and Land Surveyor stamp�nd sienature. _
31. H2 loadin r when m b ect to vehicul tr ,i �
32. Title V aonlication and fee signed by a licen ed 'ncrati�
33. Foundation footm�.2 feet above a�iucred water table
34. Lot subdrvided nnor to Julv 31 1986 - Nrtrate Loading.
35. Subdrv�ded pnor io Apn17 ]9R9 - Phosphorus Zone 300'
Plan reviewed by: ay �