Loading...
HomeMy WebLinkAboutEngineered Plan - 2015N LOT KEY: ` p.0 EXISTING CONTOUR: - - - - pF-� ! _ 4 PROPOSED CONTOUR: ••••••••••••• SPOT ELEVATION: 25.5 6„ 1 OYR 4/1 EXISTING SPOT ELEVATION: 25.5 PROPOSED 0'� TEST HOLE: * LOAMY SAND UTILITY POLE: --o- �'Ao FENCE LINE: - 90.0 HYDRANT:. D DR RETAINING WALL: ri is , WHIG PON LOCATION SF) ASSESSORS MAP: 68 PARCEL: 195 PLAN BOOK 1.90, PAGE: 79 94- SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL f USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) f SIDE AREA: (25'+ 12.8') x 2 x 2 = 151 SF (0.74) = 112 GAL/DAI BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) = 237 GAL/DA CAPACITY = 349 GAL/DAY BENCHMARK AT RIGHT CORNER OF CONC. PAD ELEVATION = 98.73 SEPTIC SYSTEM SECTION OF FINI FOUNDATION 97.1 L ELEV. a 1500 GAL SEPTIC TANK (6" OF STONE UNDER OR MECHANICALLY COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN BED ROOM I BED I LIVING ROOM ROOM BEDI BATH I DININGI SUN ROOM ROOM AREA KITCHEN DECK I I EXISTING FLOOR PLAN I �OFMASS9cy s' TERRY Jc� AN N o ° WARNER No. 38721 _T y T MAX. JU COVER1 IN) 1.75 75 _ LEV. 91 7 91.53 ELEV. ELEV. D -BOX (6" STONE UNDER) 90.0 _/ ELEV. -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 6-18-15 PERCOLATION RATE: < 2 MIN/IN NOTES: 2" PEASTONE OR FILTER FABRIC - 3/4" -1 1/2" WASHED STONE INSPECTION PORT ELEV.= 90.83 " ' ° ° ° . . IlMd 88.0 H ELEV. 4' 4' 25'x 12.8' 2 - 500 GALLON CHAMBERS WITH 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) TH-1 92.0 0/A HORIZON ELEV. LOAMY SAND 6„ 1 OYR 4/1 91.5 B HORIZON LOAMY SAND 24" 10YR 5/8 90.0 C HORIZON MEDIUM SAND 2.5Y 7/4 I 81.5 NO GROUND WATER ENCOUNTERED 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 31. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. VIN>d4f VVrvvv 1 . THOMAS J. McLkLi N, P.E. C:::::��SIT�EPLAN LOCATION: 37 WITCHWOOD RD., S. YARMOUTH, MA PREPARED FOR: MARCIA JENNER -DATE: 6-19-15 SCALE: 1" = 20' BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 02641 508-385-3426 OR 508-364-9048