HomeMy WebLinkAboutDecision 3818 - Site PlanSEPTIC SYSTEM DESIGN DATA OFFICE USE: 2725 SF (75 GPD/1000 SF) = 204 GPD SITE LIGHTING SHALL NOT CAUSE GLARE FOR MOTORISTS, PEDESTRIANS, _-1A RETAIL USE: 1825 SF ( 50 GPD/1000 SF) 91 GPD (200 GPD MIN) PROPOSED SHRUB S II PROPOSED S' CALIPER NO GARBAGE GRINDERS ALLOWED. 404 GPD DESIGN FLOW RT. 28 LOCUS 0F• �T SEPTIC TANK: PROPOSED LEACHING TRENCH/PIT 13. 404 GPD -200%- 808 GAL. REO. : USE 1500 GAL H-20 SEPTIC TANK BREAKDOWN OF SQUARE FOOTAGES ��S 1n1 1825 SF RETAIL 92 GPD LEACHING: USE 29' X 26' LEACHING FIELD= 754 SF , EXISTING BUILDING: 1775 5F OFFICE 133 GPD CAPACITY: 754 SF (.74 GPD/SF) = 558 GPD> 404 GPD. O.K.- 1418 SF RETAIL STORAGE 0.0 GPD `„q NON HABITABLE BASEMENT AREA 0.0 GPD COMMENCING WORK ON SITE, ANY VARIATION iS TO BE BROUGHT TO NEW BUILDING: 500 SF 2ND STORY PRIVATE OFFICE 38 GPD �V) 2 3 500 SF 2ND STORY RETAIL STORAGE 0 CPD FF,P° ALONG RIP EDGE TYP 931 SF 1ST FLOOR RETAIL STORAGE 0 GPD / �' 15 450 SF 1ST FLOOR OFFICE 34 GPD �S�LOADING 297 GPD (WITH RETAIL 200 GPD MIN = 404 GPD) 40 01-071 BENCHMARK: CENTER OF CATCH BASIN ELEV. 14.86' NGVD29 J 0. PTA \r \ EXISTING SEPTIC A LEACHING THIS AREA \ \ SBL TH1°S- /'� EXISTING \ � S EXISTING GREASE TRAP / PAVED PARKING EXISTING/RA15ED CONCRETE PLANTER 1 EXISTING PUMP CHAMBER// / LOT SIZE: 25,807 S/Ft (0.59 AC.t) / \ � r• �100' tyr A WITH SIGN / /VO=W ,y NG 801081 SF UT TOP FOUND SITE PLAN REVIEW DATA ASSESSORS MAP 37 PCL 145 (OLD M;,P 31 PCL G25) LO ZONING DISTRICT REQUIRED EXISTING PROPOSED DEED REFERENCE: DB 10851 PAGL 293 GENERAL NOTES: LOT SIZETAG 2125 SF 25,607 SF 25,807 16 ADDRESS: 204, 208, 210 RT. 28 IV -EST YARMOUTH FRONTAGE 125 186.16 & 164.99' 186.16 6c 164.99' FRONT SETBACK 30' 30.5' 30.5' ZONING DISTRICT: B2/R-25 (NOT na cRour!DwnrER OVERLAY DISTRICT) 1. THE LOCATION OF EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN IS SIDE SETBACK 25' 11.7' 11.7' B2 SETBACKS: 30' FRONT, 25' SIDE, 20' REAR APPROXIMATE. PRIOR TO ANY EXCAVATION ON THIS SITE, THE EXCAVATING REAR SETBACK 20' N/A N/A / R-25 SETBACKS: 30' FRONT, 15' SIDE, 20' REAR CONTRACTOR SHALL MAKE THE REQUIRED 72 HOUR NOTIFICATION TO DIG SAFE IMPERVIOUS COVERAGE 70% MAX. 84.3% 62.3% MAX. BUILDING COVERAGE 25% (1-888-344-7233) AND ANY OTHER UTILITIES WHICH MAY HAVE CABLE, PIPE OR R-25 ZONING DISTRICT REQUIRED EXISTING PROPOSED MAX. IMPERVIOUS COVERAGE: 70% EOUIPMENT IN THE CONSTRUCTION AREA FOR VERIFICATION OF LOCATIONS. FRONT SETBACK 30' 37.7' 37.7' C (YAR. PANEL 5 7/2/92 ) 2. ALL CONSTRUCTION MATERIALS, COMPONENTS, AND METHODS EMPLOYED ON THIS SIDE SETBACK 15' 3 8' 14.6-/16.1- FLOODZONE: B & PROJECT WORK SHALL CONFORM TO THE TOWN OF YARMOUTH SUBDIVISION REGULATIONS REAR SETBACK 20' N/A N/A EXISTING USE: RETAIL / OFFICE AND/OR THE MASSACHUSETTS DEPARTMENT OF PUBLIC WORKS .STANDARD PROPOSED USE: RETAIL / OFFICE SPECIFICATIONS FOR BRIDGES AND HIGHWAYS AS AMENDED TO PRESENT. EXISTING BUILDING COVERAGE: 5138 SF / 25,807 SF 19.97 ALL SEPTIC WORK AND MATERIALS TO CONFORM TO 310 CMR 15.00 TITLE 5. PROPOSED BUILDING COVERAGE: 6414 SF / 25,807 SF = 24.9% LOT SIZE: 25,807 SFf (0.59 AC.t) AND YARMOUTH HEALTH REGULATIONS. EXISTING BUILDING HEIGHT: 23'1 3. VERTICAL DATUM 15 NGVD29 FROMF.I.R.M. BENCHMARKS PROPOSED ADDITION HEIGHT: 29'1 PARKING CALCULATIONS: 4. TOPOGRAPHY AND DETAIL FROM SURVEYS BY DOWN CAPE ENGINEERING 6/01 1825 SF RETAIL (t 210) = 8.69 SPACES 5. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHTO-H20 UNLESS NOTED, EXISTING BUILDING: 1775 SF OFFICE (1/200) = 8.87 SPACES 1418 SF RETAIL STORAGE (1/2106) 0.68 SPACES NON HABITABLE BASEMENT AREA 0.0 SPACES 6. THIS PLAN IS FOR PROPOSED WORK ONLY AND IS NOT TO BE USED FOR PROPERTY LINE STAKING. NEW BUILDING: 500 SF 2ND STORY PRIVATE OFFICE (1 /2�1U) 2.50 SPACES +'s"' 7. ALL STORM RUNOFF TO BE CONTAINED ON SITE. PROVIDE VEGETATED SWALES IN 500 SF 2ND STORY RETAIL STORAGE 1/210) = 0.24 SPACE'S 4 BUFFER STRIPS AS REQUIRED TO ENSURE RUNOFF IS RETAINED. / ' WIDE 5 HIGH 931 SF 1ST FLOOR RETAIL STORAGE �1/21�)) 0.44 SPACES DENSE EVERGREEN 450 SF IST FLOOR OFFICE (1/200) 2.25 ALTERNATE ROOF DRAINAGE SYSTEM FOR REAR OF EXISTING BUILDING MAY BE / - REQUIRED IF BASEMENT TO BE UTILIZED IN FUTURE. / HEDGE / TOTAL REQUIP.(:' 23..667 SPACES SPACES S. 6" LOAM AND SEED ALL DISTURBED AREAS NOT PAVED. BENCHMARK: CENTER OF' CATCH/ SPACES PROVIDED = 24 INCL. 2 IN GARAGE 9. WATER SERVICE APPROXIMATE AS SHOWN. GAS AND CABLE UTILITIES BASIN FLEV. = 14.86' NGVD29 / 521 CMR23.2.1 - 1 HCP SPACE REO. 2 HCP "<)VIDED (INCL. VAN SPACE) TO BE INSTALLED TO THE PROPOSED BUILDING APPROXIMATELY AS SHOWN / / TREE CALCULATION: 24 (1/8) = 3 TREES PEO .,ITREES PROVIDED. (ALL SUBJECT TO FINAL DESIGN AND LOCATION AS REQUIRED BY UTILITIES VENDORS). / 10. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY OWNERS ENGINEER AND PERMISSION OBTAINED. 24 HR. NOTICE REQ. +,<„�\/ �?+ 15'R'y 11. COORDINATE UTILITY INSTALLATIONS WITH APPROPRIATE VENDORS. „?. C) EXISTING TREES OF LEAST 4" CALIPER T-qT EXIST iN BUFFER ZONES SHALL BE sat RETAINED. IF SUCHTR TREES DO NOT EXIST, CALIPER TREES SHALL BE PLANTED AT INTERVALS OF AT MOST 20' (301.4.4) (TYP. ALL PARKING BUFFERS) 12. E SITE LIGHTING SHALL NOT CAUSE GLARE FOR MOTORISTS, PEDESTRIANS, _-1A /4' WIDE 500ENSE 5 HIGH 4f V- EVERGREEI�``Q�' PROPOSED SHRUB S II PROPOSED S' CALIPER n � RT. 28 LOCUS 0F• �T - PROPOSED LEACHING TRENCH/PIT 13. 2g C ��S 1n1 7ES1 PIT LOCUS MAP SCALE 1" = 2083' `�i 5' SOIL REMOVAL ® "" 20'" INSPECTION BY OWNERS ENGINEER AND PERMISSION OBTAINED. 24 HR. NOTICE REQ. +,<„�\/ �?+ 15'R'y 11. COORDINATE UTILITY INSTALLATIONS WITH APPROPRIATE VENDORS. „?. C) EXISTING TREES OF LEAST 4" CALIPER T-qT EXIST iN BUFFER ZONES SHALL BE sat RETAINED. IF SUCHTR TREES DO NOT EXIST, CALIPER TREES SHALL BE PLANTED AT INTERVALS OF AT MOST 20' (301.4.4) (TYP. ALL PARKING BUFFERS) 12. E SITE LIGHTING SHALL NOT CAUSE GLARE FOR MOTORISTS, PEDESTRIANS, _-1A /4' WIDE 500ENSE 5 HIGH 4f V- EVERGREEI�``Q�' PROPOSED SHRUB S II PROPOSED S' CALIPER 43p e OR NEIGHBORING PREMISES. ro ro HEDGE 0F• C) J Q - PROPOSED LEACHING TRENCH/PIT 13. PROPOSED BUILDING TO HAVE SPRINKLER FIRE SUPPRESSION SYSTEM INSTALLED. STORTZ FIRE CONNECTION REQUIRED, SEE SPRINKLER PLAN BY OTHERS. LOCK BOX REO. C ��S 1n1 7ES1 PIT E- ? 14. CONTRACTOR TO VERIFY GRADES, INVERTS, ELEVATIONS AND SITE CONDITIONS PRIOR Tp THE ATTENTION `�i 5' SOIL REMOVAL ® "" 20'" PAVE `?> `„q °/ y r� 90 M� F WASHEDSTONEFRENCH DP .N lu COMMENCING WORK ON SITE, ANY VARIATION iS TO BE BROUGHT TO / LIMIT SEE NOTE �V) 2 3 DRIVE 5 FF,P° ALONG RIP EDGE TYP OF THE DESIGN ENGINEER PRIOR TO ANY WORK ON SITE. / �' 15 IN .4 �S�LOADING N N O O I � 5 I � N F IZ 15. NOTE THAT THE INSTALLATION OF THE SEPTIC SYSTEM REQUIRES REMOVAL OF UNSUITABLE SOIL>J. I I 01 1_ THE UNSUITABLE SOILS SHALL BE REMOVED FROM UNDER AND FOR 5' LATERALLY AROUND THE FROM PRIOR SYSTEMS SHALL ¢ W �, 7# A9 u PROPOSED LEACHING FIELD. ANY SOIL FOUND TO BE CONTAMINATED BE REMOVED AS WELL. THE REPLACEMENT SAND SHALL MEET 310CMR 15.223(3). /� :v , .t 7 4 24 'O 0, BOARD OF HEALTH AND OWNERS ENGINEER TO INSPECT SOIL REMOVAL. THE SAME AS FOR THE SEPTIC SYSTEM /O� C� O /F� Q' ' �6 i 23 S� '`"" \.� , G C ELEV, a 18.69 SILL / Fb / b. ELEV. - 18.78' ELEV. FIRST - 18R8� ' CRgkf Spe\F R 0� %I qC � REMOVAL FOR DRAINAGE STRUCTURES SHALL B O y v ,,.eo v t 16. EXISTING SEPTIC COMPONENTS TO BE PUMPED AND REMOVED/CRUSHED AND VOIDS FILLED WITJ / Cj .�h)F'q) P 9 IFN V , COMPACTED SAND. ALL WORK TO COMPLY WITH TITLE 5 REQUIREMENTS. �� ��� Qrv�c!v + . A�lv j J PROPOSED BUIL-14 C eG/� I PE -ROUT.. !:••.S &OTHER / 8 rl` �� 1381 SF \\ O/ip '' UTILITIES IS REQUIRED p ��4!" O/ Int 7g S� 1.5 STORY "D 'O 00. SLAB ON_GRAi aa/ Q f r / 7 ^' •'i7 , A_ 4 GUY WIRE \Q, L \ o 78 676•'Ly,� \ \ \ 9a,V STEP eo° \ \ ®c NF Oa - \\\ �//�3°, 0 v®C v 0 Nie CL l�U 1 C <lD cl _ \ \ • \ Si0 F � o "IF 0 O p O p r-\/1 P�T1A 1!1 /1 P1` 1 n 1=rl f1 A i e' rll A K I �N, SCALE: t"=20' 20 0 20 40 60 ' i Ew IC SYS �� �},s.1� Ott /e �6 ' J 62 +,ea J� i 3_CONO� �x �\ REMOVE A 1 / O'er i 10 /,i / „ rl"7 6 f- STEP'�ry Ute.. LOADING q -K522 t .- 4,' b' - t I f %� �' DOCK NEW 1500 4 �\� .� \ GAL H2O S(T 50 ✓ ...� PRO' >a / 8ii ,.�o �+� '4' STEPS ���1 5 I a \V v0O. 7,�0 �IN/. RESERVE \_.�/ �� >q.z � y *S° V Qsae 6� �� Laa�-s5' 7 13 INV. i ? 0. ,25,807 SFt PROPOSED',,(C. 2 - / CAS 4 4a, 656 r1 a T SIZE PAVED �s2 .v. Q'. \ STREET 1 r v ' REMOVE PAVEMENT AND �� ANT',R PARKING / . ova ADD WASHED STONE FRENCH \ SIGN SJ+++11 - �-: { (' '`44 .a.7Ati EXTIBUILDING/ --!- L~' DR_AINS ALONG DRIP EDGE '�. -._. _ r ,.,�. �N Fig', :\GV , 0' BUILDING (NP,) 5 - 2 / 5018 'IF y O \ \ •�.ogL'O �' - h'v%""., \�O \tiC TOP�Fovve WGUIRYEnz, s4' Q 16 £\ �..aP F( 878' o, / FIRST FLOOR CRAW CEff4 0,2 r C ELEV. = 18.6 < SpgCF Q CUT & MATCH \ \ `& * 17 GRANITE. INSTALL \ 6 \ /S8 \� ! �4 / / ` \ \ 6' TAPERED SECTION ;1-1,1 F.1 IJ TYP.� 1,7z % <F 8 \ 86 I \ s a' -- s 76 C „� \ (" : CONd, W �/ OrSJ y \ \ \ o S7EP� rq/C / RIC, J 1:12 TAPERExir T END SECTION A= fJ�� � \ VCURBIING 18 l��V RRT� (" T ,D?� V v O,e\ 19, .0 2 1j�8.0 0\ VY n .,... V�QB. 1w N 4' GRAVEL WAt'; \. \ \F-, \ •0 \\ BASELINE STATIONING f } }11..11 APPLICANT/OWNER: TAYLOR REALTY TRUST204 2 t WESTROUTE YYARMOUTH, MA 02673 CONTACT: MEHDI HOSSEINI t \� PH. 508-790-8880 \ ' --- LEGAL: ASSRD: Ardito, Sweeney. Stusse, Robertson, & Dupuy, P.C. \ EDWARD J. SWEENEY, JR. ESQ. \ \ \ 25 MID TECH DRIVE SUITE C WEST YARMOUTH, MA 02673 \ \ \ PH. 1-508-775-3433 \ \ \ FAX 1-508-790-4778 \ \ c \ �3 CIVIL ENGINEER: DOWN CAPE ENGINEERING INC. \ ARNE H. OJALA PE, PLS / DANIEL A. OJALA Err. PLS 939 MAIN STREET YARMOUTHPORT,MA 02675 \\ 1-508-362-4541 FAX PROPOSED SITE PLAN \ FAX 1-508-362-9880 \ \ SCALE: 1"=20' \ ARCHITECT: BROWN LINDOUIST FENUCCIO &RICHMOND ARCH. INC. \ 923 MAIN STREET YARMOUTHPOPT, MA 02675 PH. 1-508-362-8382 20 0 20 40 60 Feet \ FOS \ \ •" p \ FAX 1-508-362-2828 ------ \ \ O9LF \ \ p LEGEND PROPOSED SPOT GRADE PROPOSED CONTOUR EXISTING SPOT GRADF EXISTING CONTOUR WATER GATE CATCH BASIN EXISTING MANHOLE COVER UTILITY POLE GROUND LIGHT PROPOSED POLE LIGHT 35' MAX. HT, FREE STANDING SIGN GUY WIRE 0' 7 GAS GAI1: GbEi tEi ED FEB �1 - 2002, TOWN OF YARMOUTH BOARD OF APPEALS GAS I..INE _-1A WATER LINE U PROPOSED SHRUB S II PROPOSED S' CALIPER 43p e PARKING/BUFFER TREE ro ro U (1) o C) J Q - PROPOSED LEACHING TRENCH/PIT U If C ��S 1n1 7ES1 PIT E- F-- d GbEi tEi ED FEB �1 - 2002, TOWN OF YARMOUTH BOARD OF APPEALS k ul I U w L O w MM 1+1 Iq \l ro ro U (1) o C) J Q q U J Q U If C ��S 0 O `L E- F-- d k u I INI h J 0 O `L E- F-- d Q .D r.. �'" z O Q lu I I �V) 2 3 i2 J 5 1, 0 w NF- 0- x N N N O O I � 5 I � N F IZ Y E z 0 I I 01 1_ ¢ W u ~ Q W r -i `(AFi1:10J I H% S'P A O !"1 LJ In O n Q _E ul ul L1J m J Q Y 4 Q) o U) u 01-071 SHEET 1 OF 2 RM 9:0ejj h J 0 O f -•I E- F-- d Q .D r.. �'" z O Q o n 1-1 z �V) 2 3 Wg�aC4 5 1, 0 w NF- 0- x N W � 5 F IZ Y E T*+ G~A tt �"cov �R�) r -i `(AFi1:10J I H% S'P A 01-071 SHEET 1 OF 2 RM 9:0ejj