HomeMy WebLinkAboutDecision 3290 - Site and Sewage PlanLOCUS Li ROUTE 28 --___ LOCATION MAP LOT 41 (22,889 SF) ASSESSORS MAP. 26 PARCEL' T 41 CURRENT ZONING: GB BUILDING SETBACKS: F. sa S. 25' R: 20' FLOOD ZONE: C 6' WIDE WAY S BUFFER 155. 00' 12 �°s \ za TOWN OF YARMOUTH PARKING REQUIREMENTS ASSEMBLY USE( SEATS: 20 P SH -f0 OCC : 1 SPACE / 3 OCCUPANTS STANDING AREA: 120 SF 120 SF / 3 SF = 40 OCCUPANTS EMPLOYEES: 6 OCCUPANTS TOTAL OCCUPANTS = 66 TOTAL SPACES REQUIRED. 66 OCC./ 3 SPACES / OCC=22 SPACES f BITUMINOUS CONCRETE TOP COARSE 2" BITUMINOUS CONCRETEBINDER COARSE 12" (COMPACTED THICKNESS) PROCESSED GRAVEL MEETING MDPW SPEC. M1 -03J (OR EQUAL APPROVED BY TOWN ENGINEER) PAVEMENT SECTION (NOT TO SCALE) SCREENING AT REAR PROPERTY LINE TO CONSIST OF 4' WIDE x S HIGH PLANTING STRIP AND FENCE. DUMPSTER AREA .:;(5) :.:. DRIVE-THRU V& INTERVALS O O T' CALIPER EMPLOYEE TREES AT 2a LO PARKING/ L.1 IN ALL BUFFER ADING 0 ZONES PROPOSED n ((DUNXIN DONUTS [ILJr, I c I j20 OPOSA u SEATS PR Ih ONE WAY ONE WAY 13 1 n H x_26_5' .�? J r4 ...•.. �� PaR%lobs�)sF OOF 15 Q 19 b 2a-� 16 ENTRANCE l ® SIGN EXITQg:.:: 20 SIGN 20 :::'.:: BUFFER SIDZFALK ' :ESS b0':'' BUFFER•;• ; ' ' ISTING 28.5C7r RB-•CiTT SIDEWP"OpoALK / CU ism EDGE OF PAVE EXISTING GRANITE JJ EXISTING CURBING TO BE CUTBACK GRANITE CURBING TO MATCH PROPOSED CURB ROUTE -28 (TYPICAL OF 3 SECTIONS) (CUT SEE �1 (AT 4 LOCATIONS). ALK DETAILS) SITE PLAN SHOWING PARKING AND LANDSCAPING DETAILS (1" = 30') OS BUFFER 7 19.2 6' WIDE WAY 19 S BUFFER I8 Q VENT \ +'17.5 f.S.S DRAINAGE SYSTEM # 2 SEE DETAIL THIS SHEET ((GRATE ELEVATIONS = 18,0 4 7. 2 DUMP AREA . TH-2 TH-1 5 BUFFER DRAINAGE AREA # 2 / GT ST -- ` aoP MIN PROPOSED 0. L INKINI DONUTS 1 EXISTING EXISTING BUILDING) GAURD RAIL (20 RS� S) TO BE REMOVED I rxrs . le LOOEL- 21D 10' 19 o DOWN- -E 80111 MIN I SPOUTS iJpS w EXISTING 20.5 BUILDING \ +19. 4 j� � 1' 20 5 DRAINAGE G , , I AREA # 1 \ EXISTING BE CATCH :. �.BASIN ABANDONED ly '\ Ta W (EXIST.) EXISTING ISLAND TO BE REMOVED 2a f9 19.5; 20.3 ....' SIDEWALS 0. 4 19.4 F 19.3 ' Yb3 � -� STING 19.8 _ t ALK CU IRIGr PROPOSED 19.2 AXI 19.0 EDGE OF I a. SIDPAVE EXISTING GRATE ELEVATION a 19B DRAINAGE SYSTEM #1 GRANITE CURBINGSEE DETAIL THIS SHEET (TYPICAL OF 3 SdCTIdNS) ROUTE 28 CRATE ELEVATIONS a 192 SITE PL11 N SHOWING DRAINAGE AND SEPTIC SYSTEM DETAILS (1" = 30') i 114" 1 TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS. AMY VON HONE R.S. DATE: 9-13-95 PERCOLATION RATE: < 2 MIN/IN T H-1 T H-2 18.5 18B 18 LOAMY SAND FILL EL 1. VERTICAL DATUM. ASSUMED FROM QUAD (NGVD +f-) A HORIZON 2. MUNICAPAL WATER IS AVAILABLE. LOAMY SAND r4^ IOYR 312 16 B HORIZON 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. LOAMY SAND 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE f0" IOYR 414 16D 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE Cl HORIZON STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL KEY: MED -FINE SAND EXISTING CONTOUR: - - -- 18 2.5Y 7/6 14.5 EXISTING SPOT ELEVATION: 25.5 C2 HORIZON PROPOSED SPOT ELEVATION: 25 EXCEED 3.0'. MED -FINE SAND 11. EXISTING SEPTIC TANK TO BE PUMPED AND REMOVED. EXISTING LEACH " 2.5Y 7 3 105 12. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. C3 HORIZON 9.0 JC�r FINE SAND2.5Y RETAINING WALL: ® 14. ALL UNSUITABLE SOIL WITHIN 5' OF DRAINAGE AND SEWAGE LEACHING 612S 6D r EV 14" LOAMY SAND FILL ELEV A HORIZON LOAMY SAND .5 28" IOYR 312 16.5 B HORIZON LOAMY SAND 36" IOYR 414 15B Cf HORIZON MED -FINE SAND 48" 2.5Y 716 14B C2 HORIZON �J. 128 MED -FINE SAND ................ 72" 2.5Y 7/312B 114" C3 HORIZON 9.S FINE SAND 96" 2.5Y 612,5 10.8 C3 HORIZON FINE SAND f2d 2.5Y 612.5 8B USGS GROUNDWATER ADJUSTMENT. WELL: MIW-29, ZONE: B, ADJUSTMENT. 3.0 (8 OUT OF 10 YR HIGH) RAMP SIDEWALK RAMP 16 --- 61-00 28.5 61- 0" RAMP EXISTING SIDEWALK 6" 6'- o" SIDEWALK DETAIL ! 2 DRAINAGE SYSTEM CALCULATIONS (DRAINAGE AREA # 1) 1. AVERAGE RUNOFF COEFFICIENT. TOTAL IMPERVIOUS AREA (PAVE): 8,600 SF TOTAL PERVIOUS AREA: 3,000 SF C = 0.74 2. RAINFALL INTENSITY. DISTANCE = 120' C (AVG) = 0.74 STORM FREQUENCY = 25 YEARS I=5IN/HR 3. CALCULATED FLOW RATE (Q): CIA (0. j( = (0. CAL / MIN (0.27 ACRES) (7.48 GAL/CF) (60 SEC/MIN) 4. APPROXIMATE LEACHING AREA REQUIRED: HEAVY FRAME DUTY CAST IRON -CAST IRON FRAME (8") AND GRATE (H-20)AND COVER 0 ELEV = 178 4 MIL POLY 4' PEASTONE 3/4" - 1 1/2' WASHED STONE ALL AROUND (448 GAL / MIN) / (0.7 GAL / SF / MIN) = 640 SF I I w I I I. .I I W III / / III 1 1' . ' . '1 13.7 ELEV. 5. USE 7 LEACHING CALLIES WITH 3' OF STONE ALL AROUND 3 SOLID CONC. E g� 'E SIDE AREA: (34 + 10) x 2 x 4' DEEP = 352 SF CATCH BASINS E 34' BOTTOM AREA: 34 x 10 = 340 SF (H-20) TOTAL = 692 SF (SOLID BOTTOMS) 7 LEACHING CALLIES WITH T OF STONE ALL AROUND DRAINAGE SYSTEM CALCULATIONS (DRAINAGE AREA # 2) 1. AVERAGE RUNOFF COEFFICIENT: TOTAL IMPERVIOUS AREA (PAVE). 8,900 SF TOTAL PERVIOUS AREA: 1,815 SF C = 0.8 2. RAINFALL INTENSITY: DISTANCE = 120' C(AVG =0.8 STORMFREQUENCY = 25 YEARS 1=5IN/HR 3. CALCULATED FLOW RATE (Q): Q=CIA Q = (0.8) (5 IN/HR) (0.24 ACRES) (7.48 CAL/CF) (60 SEC/MIN) Q=430 GAL/MIN 4. APPROXIMATE LEACHING AREA REQUIRED: (430 GAL / MIN) / (0.7 GAL / SF / MIN) = 615 SF (34' x 10' x 4' DEEP) (H-20) DRAINAGE SYSTEM SECTION HEAVY DUTY CAST IRON FRAME (6") AND GRATE (H-20) ELEV. = 16B ELEV. = 18A 4 MIL POLY 4" PEASTONE y 3 4" 1 f 2" HASHED TONE 12" ALUM. CORK. PIPE p o a ALL AROUND 625' o AND UNDER 4' ELEV. = 158 : ' '•'•' 13.6 �> �> ELEV. 5. USE 8 HIGH CAPACITY INFILTRATORS WITH P OF STONE ALL AROUND 2 SOLID CONC. a 52' a• AND 2' UNDER (52' x 5' x 3' DEEP) (H-20) CATCH BASINS SIDE AREA: (52 + 5) x 2 x 3' DEEP = 342 SF (H-20) 8 HIGH CAPACITY INFILTRATORS WITH T OF STONE ALL AROUND BOTTOM AREA: 52 x 5 = 260 SF (SOLID BOTTOMS) AND 2' UNDER (52' x 5' x 3' DEEP) (H-20) TOTAL = 602 SF DRAINAGE SYSTEM SECTION SEPTIC SYSTEM DESIGN SEPTIC SYSTEM SECTION. -- --- - 2" PEASTONE FLOW ESTIMATE: (1000 GAL/DAY MINIMUM) HEAVY DUTY COVERS AT HEAVY DUTY COVERS AT OF 3/4" - 1 1/2" 20 SEATS AT 20 GAL/DAY/SEAT = 400 GAL/DAY 21D FINISHED GRADE FINISHED GRADE WASHED STONE Lr FIRST FLOOR SEPTIC TANK: � INSPECTION COVER 1000 GAL/DAY x 2 DAYS = 2000 GAL T7 T7 T7 USE 2000 GALLON SEPTIC TANK 1895 ELEVZ18.75 1815 ELEV.= 18.0 LEACHING AREA: (KIT') ELEV. f8.22 18.75 16 ELEV. D -BOX m 16.3 USE 12 CULTEC CHAMBERS (RECHARGER 180) WITH 4 1000 CAL 2000 GAL OF STONE AROUND SIDES AND 2.5' AT ENDS ELEV. GREASE TRAP (H-20) ELEV. SEPTIC TANK (H-20) (6" OF ELEy 2.5' 25; ELEV. ELEV. (6" OF STONE UNDER OR (6" OF STONE UNDER OR ELEV. STONE E 100'- 4•(I (110' x 11 z 14" DEEP) (H-20) (BATHS) MECHANICALLY COMPACTED) MECHANICALLY COMPACTED) UNDER) 17.47 12 CULTEC CHAMBERS (RECHARGER 180) (H-20) ELEV. WITH 4' OF STONE AROUND SIDES AND SIDE AREA.- (100 + 11)2 x 1.17 = 260 (.74) = 192 GAL/DAY 2.5 AT ENDS (100' x IV x 1.17' DEEP) (H-20) BOTTOM AREA: 100' x 11 = 1100 SF (.74) = 14_ CAL/DAY TEE SIZES: TEE SIZES: INLET: 6" UP, 25" DOWN INLET: 6" UP, 13" DOWN ADJUSTED GROUNDWATER ELEV= 12.3 TOTAL CAPACITY = 1006 GAL/DAY OUTLET: 6" UP, 36" DOWN OUTLET: 6" UP, 14" DOWN NOTES: 1. VERTICAL DATUM. ASSUMED FROM QUAD (NGVD +f-) 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-20 LOADING SPECIFICATIONS. 5. PIPE PITCH = -1/8" & 1/4" PER FOOT, (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL KEY: HEALTH REGULATIONS. EXISTING CONTOUR: - - -- 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR PROPOSED CONTOUR: .............................. TO CONSTRUCTION. EXISTING SPOT ELEVATION: 25.5 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT _TO PROPOSED SPOT ELEVATION: 25 EXCEED 3.0'. TEST HOLE: 11. EXISTING SEPTIC TANK TO BE PUMPED AND REMOVED. EXISTING LEACH AREA TO BE LOCATED AND REMOVED. UTILITY POLE: -0- 12. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. FENCE LINE: 13. SEWER LINES WITHIN 10' OF WATER LINE TO BE ENCASED WITHIN A HYDRANT: -& SECTION OF 6" PVC PIPE. RETAINING WALL: ® 14. ALL UNSUITABLE SOIL WITHIN 5' OF DRAINAGE AND SEWAGE LEACHING TREE: n AREAS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. FINE SAND f2d 2.5Y 612.5 8B USGS GROUNDWATER ADJUSTMENT. WELL: MIW-29, ZONE: B, ADJUSTMENT. 3.0 (8 OUT OF 10 YR HIGH) RAMP SIDEWALK RAMP 16 --- 61-00 28.5 61- 0" RAMP EXISTING SIDEWALK 6" 6'- o" SIDEWALK DETAIL ! 2 DRAINAGE SYSTEM CALCULATIONS (DRAINAGE AREA # 1) 1. AVERAGE RUNOFF COEFFICIENT. TOTAL IMPERVIOUS AREA (PAVE): 8,600 SF TOTAL PERVIOUS AREA: 3,000 SF C = 0.74 2. RAINFALL INTENSITY. DISTANCE = 120' C (AVG) = 0.74 STORM FREQUENCY = 25 YEARS I=5IN/HR 3. CALCULATED FLOW RATE (Q): CIA (0. j( = (0. CAL / MIN (0.27 ACRES) (7.48 GAL/CF) (60 SEC/MIN) 4. APPROXIMATE LEACHING AREA REQUIRED: HEAVY FRAME DUTY CAST IRON -CAST IRON FRAME (8") AND GRATE (H-20)AND COVER 0 ELEV = 178 4 MIL POLY 4' PEASTONE 3/4" - 1 1/2' WASHED STONE ALL AROUND (448 GAL / MIN) / (0.7 GAL / SF / MIN) = 640 SF I I w I I I. .I I W III / / III 1 1' . ' . '1 13.7 ELEV. 5. USE 7 LEACHING CALLIES WITH 3' OF STONE ALL AROUND 3 SOLID CONC. E g� 'E SIDE AREA: (34 + 10) x 2 x 4' DEEP = 352 SF CATCH BASINS E 34' BOTTOM AREA: 34 x 10 = 340 SF (H-20) TOTAL = 692 SF (SOLID BOTTOMS) 7 LEACHING CALLIES WITH T OF STONE ALL AROUND DRAINAGE SYSTEM CALCULATIONS (DRAINAGE AREA # 2) 1. AVERAGE RUNOFF COEFFICIENT: TOTAL IMPERVIOUS AREA (PAVE). 8,900 SF TOTAL PERVIOUS AREA: 1,815 SF C = 0.8 2. RAINFALL INTENSITY: DISTANCE = 120' C(AVG =0.8 STORMFREQUENCY = 25 YEARS 1=5IN/HR 3. CALCULATED FLOW RATE (Q): Q=CIA Q = (0.8) (5 IN/HR) (0.24 ACRES) (7.48 CAL/CF) (60 SEC/MIN) Q=430 GAL/MIN 4. APPROXIMATE LEACHING AREA REQUIRED: (430 GAL / MIN) / (0.7 GAL / SF / MIN) = 615 SF (34' x 10' x 4' DEEP) (H-20) DRAINAGE SYSTEM SECTION HEAVY DUTY CAST IRON FRAME (6") AND GRATE (H-20) ELEV. = 16B ELEV. = 18A 4 MIL POLY 4" PEASTONE y 3 4" 1 f 2" HASHED TONE 12" ALUM. CORK. PIPE p o a ALL AROUND 625' o AND UNDER 4' ELEV. = 158 : ' '•'•' 13.6 �> �> ELEV. 5. USE 8 HIGH CAPACITY INFILTRATORS WITH P OF STONE ALL AROUND 2 SOLID CONC. a 52' a• AND 2' UNDER (52' x 5' x 3' DEEP) (H-20) CATCH BASINS SIDE AREA: (52 + 5) x 2 x 3' DEEP = 342 SF (H-20) 8 HIGH CAPACITY INFILTRATORS WITH T OF STONE ALL AROUND BOTTOM AREA: 52 x 5 = 260 SF (SOLID BOTTOMS) AND 2' UNDER (52' x 5' x 3' DEEP) (H-20) TOTAL = 602 SF DRAINAGE SYSTEM SECTION SEPTIC SYSTEM DESIGN SEPTIC SYSTEM SECTION. -- --- - 2" PEASTONE FLOW ESTIMATE: (1000 GAL/DAY MINIMUM) HEAVY DUTY COVERS AT HEAVY DUTY COVERS AT OF 3/4" - 1 1/2" 20 SEATS AT 20 GAL/DAY/SEAT = 400 GAL/DAY 21D FINISHED GRADE FINISHED GRADE WASHED STONE Lr FIRST FLOOR SEPTIC TANK: � INSPECTION COVER 1000 GAL/DAY x 2 DAYS = 2000 GAL T7 T7 T7 USE 2000 GALLON SEPTIC TANK 1895 ELEVZ18.75 1815 ELEV.= 18.0 LEACHING AREA: (KIT') ELEV. f8.22 18.75 16 ELEV. D -BOX m 16.3 USE 12 CULTEC CHAMBERS (RECHARGER 180) WITH 4 1000 CAL 2000 GAL OF STONE AROUND SIDES AND 2.5' AT ENDS ELEV. GREASE TRAP (H-20) ELEV. SEPTIC TANK (H-20) (6" OF ELEy 2.5' 25; ELEV. ELEV. (6" OF STONE UNDER OR (6" OF STONE UNDER OR ELEV. STONE E 100'- 4•(I (110' x 11 z 14" DEEP) (H-20) (BATHS) MECHANICALLY COMPACTED) MECHANICALLY COMPACTED) UNDER) 17.47 12 CULTEC CHAMBERS (RECHARGER 180) (H-20) ELEV. WITH 4' OF STONE AROUND SIDES AND SIDE AREA.- (100 + 11)2 x 1.17 = 260 (.74) = 192 GAL/DAY 2.5 AT ENDS (100' x IV x 1.17' DEEP) (H-20) BOTTOM AREA: 100' x 11 = 1100 SF (.74) = 14_ CAL/DAY TEE SIZES: TEE SIZES: INLET: 6" UP, 25" DOWN INLET: 6" UP, 13" DOWN ADJUSTED GROUNDWATER ELEV= 12.3 TOTAL CAPACITY = 1006 GAL/DAY OUTLET: 6" UP, 36" DOWN OUTLET: 6" UP, 14" DOWN 24 SCHOIL STREET P.O. BOX 463 DM # 95-090 WEST "NNIS, MASSACHUSETTS 02670 155.00' 4 �a SIDEWALK EXISTING 28S EDGE OF PAVE CURB -CUT ROPOSED XI SIDEWALK I CURB -4 UT C 105 - ---I----I-- 106 -- 1 --- +94BO +1791 +4480 +7480 +291 +2791 +4731 - +72.91 STATE HIGHWAY ROUTE 28 (1934 ALTERATION LAYOUT) CURB CUT DETAIL (1" = 30') T}IGhI "S J. �ra,vr�a 14•iELIAy U' � - �f ''J:)HN "`�Cy'�i CIVIL N. 36171 THOMAS McLELLAN, P;E. 11 JOHN Z. DEMAREST JR., P.L.S. SITE AND SEWAGE PLAN LOCATION.- 626 OCATION626 ROUTE 28 WEST YARMOUTH, MA PREPARED FOR - GEORGE ZOGRAFOS (DUNKIN DONUTS) SCALE: i = 30' DATE: 10-4-95 REFERENCE: LAND COURT CASE 26266D REV. 3-7-96 NOTES: 1. VERTICAL DATUM. ASSUMED FROM QUAD (NGVD +f-) 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-20 LOADING SPECIFICATIONS. 5. PIPE PITCH = -1/8" & 1/4" PER FOOT, (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL KEY: HEALTH REGULATIONS. EXISTING CONTOUR: - - -- 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR PROPOSED CONTOUR: .............................. TO CONSTRUCTION. EXISTING SPOT ELEVATION: 25.5 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT _TO PROPOSED SPOT ELEVATION: 25 EXCEED 3.0'. TEST HOLE: 11. EXISTING SEPTIC TANK TO BE PUMPED AND REMOVED. EXISTING LEACH AREA TO BE LOCATED AND REMOVED. UTILITY POLE: -0- 12. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. FENCE LINE: 13. SEWER LINES WITHIN 10' OF WATER LINE TO BE ENCASED WITHIN A HYDRANT: -& SECTION OF 6" PVC PIPE. RETAINING WALL: ® 14. ALL UNSUITABLE SOIL WITHIN 5' OF DRAINAGE AND SEWAGE LEACHING TREE: n AREAS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. STORM -WATER FLOW: -o 15. ALL STORM WATER RUN-OFF TO BE CONTAINED ON SITE. 16. DESIGN ENGINEER TO INSPECT AND CERTIFY ALL SITE WORK. 17. EXISTING WATER SERVICE TO BE EXTENDED TO ENTER BUILDING AT REAR (UTILITY ROOM). SERVICE AT SIPF OF BUILDING TO BE ABANDONED. DM DEMARE. -McLELLAN McLELLAN ENGINEERING 24 SCHOIL STREET P.O. BOX 463 DM # 95-090 WEST "NNIS, MASSACHUSETTS 02670 155.00' 4 �a SIDEWALK EXISTING 28S EDGE OF PAVE CURB -CUT ROPOSED XI SIDEWALK I CURB -4 UT C 105 - ---I----I-- 106 -- 1 --- +94BO +1791 +4480 +7480 +291 +2791 +4731 - +72.91 STATE HIGHWAY ROUTE 28 (1934 ALTERATION LAYOUT) CURB CUT DETAIL (1" = 30') T}IGhI "S J. �ra,vr�a 14•iELIAy U' � - �f ''J:)HN "`�Cy'�i CIVIL N. 36171 THOMAS McLELLAN, P;E. 11 JOHN Z. DEMAREST JR., P.L.S. SITE AND SEWAGE PLAN LOCATION.- 626 OCATION626 ROUTE 28 WEST YARMOUTH, MA PREPARED FOR - GEORGE ZOGRAFOS (DUNKIN DONUTS) SCALE: i = 30' DATE: 10-4-95 REFERENCE: LAND COURT CASE 26266D REV. 3-7-96