Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Decision 3769 - K - Fire Suppression Plan
MAIN STREET S: N v I SITE PLAN 40 0 40 80 SCALE: 1 "=40' GRAPHIC SCALE 19.'i' -RN Cf)NCRFTF MAT TYPICAL MAIN ISLAND PROTECTION SYSTEM (MOUNTED ON �\ `_�,� (INSTALLED ON 70P OF OF CANOPY) (7 J� , ,`v CANOPY DECK) OF CANOP �� _ � ; "HAZARD AREA" I I UNDENIED ON r- UNDERSURFACE 1 �- OF CANOPY) 6 5 I I I I ' 7 MENOMONIE SELF SERVO � I WARNING R IS UNLAWFUL AND DANGEROUS TO DISPENSE GASOUNE INTO UNAPPROVED CONTAINERS ... ' 'I , I S , 1pllr�=Iqq x 2 ' W o x 7 i SELF SERVO � I WARNING R IS UNLAWFUL AND DANGEROUS TO DISPENSE GASOUNE INTO UNAPPROVED CONTAINERS ... ' 'I , I S , n ------------------------------I-, (INSTALLED ON TOP OF CANOPY DECK) 'A" I NOTE: I "HA SEE DETAIL 13 (NOZZLE AIMING POINTS) FOR NOZZLE AIMING POINT LOCATION DIMENSIONS ISLAND END ELEVA 77ON TYPICAL END OF ISLAND PROTECTION SYSTEM NOT TO SCALE ISLAND PLAN VIEW SCALE: Ys RED BACKGROUND W/WHITE MASKING SIGN SPECIFICATIONS DIMENSIONS: 12"X16" COLOR: WHITE BACKGROUND W/ RED MASKING SINGLE -SIDED DECAL APPLIED TO DISPENSER IN VISABLE LOCATION, LETTERING SIZE AND LOCATION SHALL BE AS SHOWN ABOVE. AVAILABLE FROM LOCAL PRINTER. DETAIL 1 SIGN NOT TO SCALE DETAIL 2 FOUR SIDES OF SELF SERVE AREAS). POSITIVE LIMITING BARRIER NOT TO SCALE DETAIL 3 NOZZLE AIMING POINTS NOT TO SCALE GENERAL NOTES (1) THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND THE PROPOSED NEW WORK. HE SHALL BE RESPONSIBLE FOR THE FIELD CONFIRMATION OF ALL ITEMS ON THE PLAN AND SHALL IMMEDIATELY NOTIFY THE OWNER IN WRITING OF ANY DISCREPANCY BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF THE ENTIRE SYSTEM AND SHALL COMPLY WITH THE REGULATIONS SET FORTH BY THE PREVAILING CODE AND THE REQUIREMENTS OF THE EQUIPMENT MANUFACTURER. (2) THE INSTALLATION OF THIS FIRE EXTINGUISHING SYSTEM MUST BE IN ACCORDANCE WITH THE PREVAILING MASSACHUSETTS CODE REQUIREMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD CONFIRMATION OF ALL ITEMS ON THE PLAN AND SHALL NOTIFY THE DESIGNER IN WRITING OF ANY DISCREPANCY IMMEDIATELY BEFORE PROCEEDING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF THE ENTIRE SYSTEM AND SHALL COMPLY WITH THE REGULATIONS SET FORTH BY THE PREVAILING MASSACHUSETTS CODE AND THE EQUIPMENT MANUFACTURER SPECIFICATIONS. (3) NO FIXED FIRE EXTINGUISHING SYSTEM WILL BE INSTALLED UNTIL AND ONLY AFTER THE DATE OF APPROVAL OF THE SELF-SERVICE MOTOR FUEL FACILITY. THE INSTALLATION SHALL BE TAKEN FROM AND IN ACCORDANCE WITH APPROVED STAMPED PLANS FROM THE STATE FIRE MARSHAL MARKED SUPPRESSION SYSTEM "INSTALLER COPY'. VIOLATION OF THIS STATEMENT WILL NULLIFY AND VOID THE APPROVAL OF THIS SELF-SERVICE APPLICATION. IF THE INSTALLATION OF THE SUPPRESSION SYSTEM OCCURS BEFORE THE STATE FIRE MARSHAL APPROVAL DATE, AND IS NOT TAKEN FROM THE APPROVED/STAMPED PLANS ISSUED BY THE FIRE MARSHAL'S OFFICE, IT SHALL BE AT THE EXPENSE AND PERIL OF THE LICENSEE. (4) THE FIXED FIRE EXTINGUISHING SYSTEM SHALL BE INSTALLED BY "FACTORY AUTHORIZED" PERSONNEL HAVING A CURRENT AND VALID "CERTIFICATE OF COMPETENCY" ISSUED BY THE COMMONWEALTH OF MASSACHUSETTS THROUGH THE STATE FIRE MARSHAL. EACH PERSON ENGAGED IN THE INSTALLATION, SERVICING, CHARGING, RECHARGING, REPAIR, TEST AND INSPECTION OF ENGINEERED OR PRE-ENGINEERED FIXED FIRE EXTINGUISHING SYSTEMS IN MASS. MUST HAVE A CERTIFICATE OF COMPETENCY ISSUED BY THE STATE FIRE MARSHAL OF THE DEPARTMENT OF PUBLIC SAFETY. MASSACHUSETTS FIRE PREVENTION RULE 527 CMR 23 REQUIRES EVERY PERSON HOLDING A VALID CERTIFICATE OF COMPETENCY, UPON DEMAND, SHOW AND PERMIT THE EXAMINATION OF SUCH CERTIFICATE BY THE MARSHAL,, HEAD OF THE FIRE DEPARTMENT, OR DESIGNEES. (5) THE DIKE, LOW HUMP, OR APPROVED STATE FIRE MARSHAL POSITIVE LIMITING BARRIER MAY BE INSTALLED AT ANY TIME. (6) THE LICENSED INSTALLING CONTRACTOR SHALL INSURE THAT THE LIMITS OF THE FIRE SUPPRESSION SYSTEM ARE NOT EXCEEDED. (7) THE INSTALLING CONTRACTOR SHALL TEST FIRE THE ENTIRE SYSTEM, INCLUDING ALL CONTROLS AND SHALL CERTIFY TO THE OWNER IN WRITING OF THE SYSTEM'S SATISFACTORY OPERATIONAL PERFORMANCE AND COMPLIANCE WITH U.L. APPROVAL. (8) ATSEMIANNALLY, ALLHEAL ECTORS,UETC. SHALLDIBE INSPECTED BY APPROVED AND CERTSCHARGE NOZZLES, PIPINDRY IFIED COMPANIES WITH A VALID MASSACHUSETTS ISSUED CERTIFICATE OF REGISTRATION UNDER 527 CMR 23.00, COMPANY TYPES B & C (43&44) AND INDIVIDUAL TYPES F & G (47&48). THE REPORTS OF SUCH INSPECTIONS SHALL BE SUBMITTED TO THE HEAD OF THE FIRE DEPARTMENT IN ACCORDANCE WITH NFPA STANDARDS (NFPA-17, 1994 EDITION). (9) EXISTING SELF SERVICE FACILITIES SHALL BE SUBJECTED TO RESUBMITTAL AND REVIEW SHOULD ANY OF THE FOLLOWING ITEMS OCCUR: (A) METHOD OF DISPENSING MOTOR FUEL. (B) ALTERATIONS TO THE PRE-ENGINEERED FIXED EXTINGUISHING SYSTEM(S) OTHER THAN NORMAL MAINTENANCE PROCEDURES. (C) ALTERATIONS TO THE SELF SERVICE DISPENSING ISLAND ARRANGEMENT(S) RESULTING IN A CHANCE OF HAZARD AREA PROTECTION, (0) ALTERATIONS OR ENVIRONMENTAL CHANGES RESULTING IN THE INABILITY OF A CONSOLE OPERATOR TO CONSTANTLY OBSERVE THE DISPENSING OPERATION. THIS ITEM SHALL BE DETERMINED BY THE LOCAL HEAD OF FIRE DEPARTMENT. (10) EXISTING AND NEW UNDERGROUND TANKS FOR THE PROPOSED FACILITY SHALL BE REGISTERED WITH THE STATE FIRE MARSHAL'S OFFICE (FORM F.P. 290). THIS FORM SHALL BE SUBMITTED FOR EACH TANK WITH THE SUBMITTAL PACKAGE. EACH TANK SHALL BE ALPHABETICALLY OR NUMERICALLY CODED AND DULY NOTED ON THE SITE PLAN. (11) PRODUCT PIPING SHALL MEET THE MATERIAL AND INSTALLATION STANDARDS SET FORTH IN THE 527 CMR 9. (12) THE CONTROLLING MECHANISM CONSOLE SHALL INCLUDE A DISCONNECT SWITCH WHICH WILL INSTANTLY CUT OFF ALL PUMPING POWER TO ALL MOTOR FUEL PUMPS AT THE SERVICE STATION. THE CONTROLLING MECHANISM CONSOLE, SWITCHES AND RELATED EQUIPMENT SHALL BE OF A DESIGN AND TYPE APPROVED BY THE FIRE MARSHAL AND SHALL BE UNDERWRITERS LABORATORIES (U.L.) LISTED EQUIPMENT. (13) THE POSITIVE LIMITING BARRIER TO BE CONTINUOUS SQUARE OR "V" GROOVE 3/4 X3/4" DEEP ON 4 314" CENTERS WITH CROSS INTERCONNECTING GROOVES EITHER SQUARE OR "V GROOVES EQUALLY SPACED ON MIN. 12" MAX. 46" CENTERS. THE OUTSIDE GROOVES TO BE AT LIMIT OF HAZARD PROTECTION AREA AND THE POTENTIAL SPILL AREA TO BE WITHIN THIS PROTECTION AREA. GROOVES MAY BE SAW CUT OR SCORED INTO CONCRETE MAT. GROOVES MUST BE KEPT CLEAN AT ALL TIMES (SEE DETAIL LEFT). THE POSITIVE LIMITING BARRIER SHALL BE 10'-0" MAXIMUM DISTANCE FROM CENTER LINE OF DISPENSER. CONTRACTOR SHALL FIELD ADJUST POSITIVE LIMITING BARRIER TO CLEAR ALL MANHOLES AND/OR OPENINGS WITHIN THE POSITIVE LIMITING BARRIER OR MODIFY ALL SUCH MANHOLES AS REQUIRED WITH ELEVATED, BOLTED AND GASKETED COVERS. (14) NOZZLE AND HOSE FROM EACH PETROLEUM PRODUCT DISPENSER SHALL NOT EXTEND BEYOND POSITIVE LIMITING BARRIER AND NO PETROLEUM PRODUCT SHALL BE DISPENSED BEYOND POSITIVE LIMITING BARRIER. USE OF ANY "HOLD OPEN CLIPS" ON SELF SERVE DISPENSERS IS PROHIBITED EXCEPT WHERE U.L. LISTED STAGE 11 VAPOR RECOVERY NOZZLES ARE USED WHICH WILL AUTOMATICALLY SHUT OFF IF THE NOZZLE IS REMOVED FROM THE FILL PIPE. (15) STATE FIRE MARSHAL APPROVED SIGNS SHALL BE INSTALLED TO BE VISIBLE FROM BOTH ENDS OF A SELF SERVE DISPENSING ISLAND. (SEE DETAIL 1) (16) MOUNT 2 SIGNS AT CONSOLE IN OPERATOR'S FULL VIEW: A. "DO NOT ENERGIZE PUMPS UNLESS VEHICLE ENGINE IS SHUT OFF AND PEOPLE ARE NOT SMOKING." S. "IN CASE OF FIRE, PULL EMERGENCY SWITCH FOR SYSTEM ACTIVATION, THEN CALL THE FIRE DEPARTMENT." (17) IF CARD READING DEVICES OR CASH RECEPTORS ARE INSTALLED AT THIS FACILITY; THEY SHALL BE SUBJECT TO THE FOLLOWING CONDITIONS: A. THE AUTOMATIC CREDIT CARD OR CASHING READING DEVICE SHALL NOT BE USED AS PHYSICAL AUTHORIZATION FOR THE DISPENSING OF GASOLINE, BUT RATHER EACH SALE SHALL BE INDIVIDUALLY AUTHORIZED BY THE SELF SERVE ATTENDANT. B. THE SELF SERVE FACILITY MEETS ALL OTHER APPLICABLE PROVISIONS. (18) A MENS SHALL BE PROVIDED FOR THE CONTROLLING MECHANISM CONSOLE OPERATOR TO OBSERVE THE FILLING OPERATION AT EACH VEHICLE AND THE DISPENSING OF MOTOR FUEL SHALL BE CONTINUOUSLY OBSERVED BY THE CONSOLE OPERATOR DURING THE TIME THAT ANY OF THE PUMPS HAVE BEEN ACTIVATED TO DISPENSE MOTOR FUEL. CONSTANT CONTACT BETWEEN THE CONSOLE OPERATOR AND THE DISPENSING ISLAND BY MEANS OF AN INTERCOMMUNICATIONS SYSTEM SHALL BE MAINTAINED. (19) UNRELATED BUSINESS: VENDING AREAS, CONVENIENCE FOOD MART, AUTOMOTIVE REPAIR GARAGE, AND SIMILAR BUSINESS SHALL BE OPERATED BY OTHERS. EXCEPTION: FACILITIES OF 1,000 S.F. OR LESS OF RETAIL SALES AREA AND EIGHT OR LESS FUELING POSITIONS MAY BE OPERATED BY ONE ATTENDANT AT THE DISCRETION OF THE HEAD OF THE FIRE DEPARTMENT. (20) ALL DISCHARGE PIPING, TEES, ELBOWS UNIONS AND FITTINGS THAT ARE PART OF THE DISTRIBUTION SYSTEM OF THE DRY CHEMICAL PRE-ENGINEERED FIXED FIRE EXTINGUISHING SYSTEM AT SELF SERVE MODE MOTOR FUEL FACILITIES SWILL BE SCHEDULE 40 THREADED GALVANIZED STEEL PIPE. VEHICLE CAPACITY FUELING WAITING TO BE FUELEDPARKING TOTAL SELF SERVICE 16 8 19 43 FULL SERVICE ISLAND I STANDARD I END I TOTAL PER ISL. 4 0 2r-0" 4 m/ 24 Momrs 1 2 en./ 12 mmss 6 cm, 36 No2ars TOTAL AT FACILITY = 24 en✓ 144 Names LEGEND 10 160' AUTOMATIC THERMOSTAT INTERCONNECTED TO FIRE SUPPRESSION SYSTEM INSTALLED ON 15 FOOT MAXIMUM CENTERS IN A SINGLE LINE OVER THE CENTER OF THE ISLAND. IF THERE IS A CANOPY OVER THE ISLAND, THE DETECTOR SHALL BE MOUNTED ON ITS UNDER SURFACE, PROVIDING THE HEIGHT DOES NOT EXCEED 15 FEET ABOVE THE ROADBED. IF THERE IS NO CANOPY THE DETECTOR SHALL BE LOCATED NO HIGHER THAN THE NOZZLES AND MOUNTED ON THE UNDER SURFACE OF AN 187r18"x2" HEAT COLLECTOR. O2 CURVED MIRRORS OR C.C.T.V. CAMERAS AND MONITORS WHERE REQUIRED. O INTERCOM SPEAKERS AT EACH COLUMN OR DISPENSER WITH MASTER CONTROL LOCATED AT CENTRAL AREA. O DRY CHEMICAL CYLINDERS AS REQUIRED BY MANUFACTURER OF SUPPRESSION SYSTEM WITH REFERENCE TO U/L APPROVED INSTALLATION AND MAINTENANCE MANUAL. O5OVERHEAD FIRE SUPPRESSION PIPING TO BE CALV. SCH. 401 (DISTRIBUTION AND SUPPLY), © NOZZLE O7 NO SMOKING TURN OFF ENGINE SIGN - 12" X 16" - SINGLE -SIDED DECAL APPLIED TO DISPENSER IN VISIBLE LOCATION. LETTERING SIZE AND LOCATION SHALL BE AS DETAIL 1. OS HAND OPERATED 10f BC FIRE EXTINGUISHER. 90 FIRE SUPPRESSION STRIKE POINT. 70 COLUMN OR LIGHT POLE 11 GASOLINE DISPENSING PUMP U/L APPROVED 12 POSITIVE LIMITING BARRIER AROUND PERIMETER OF SELF SERVE GASOLINE DISPENSING AREA. 13 SELF SERVE GASOLINE DISPENSING AREA, 14 APPROPRIATE INSTRUCTIONS FOR USE AT EACH SELF SERVE DISPENSER 15 DIRECTION OF TRAFFIC & "NO PARKING" PAINTED ON PAVEMENT (WHERE REQUIRED) 16 SAFETY BARRICADE 17 LIGHTING WITHIN SELF SERVE DISPENSING AREA 0 18 CONCRETE MAT (IS GENERALLY LEVEL) 19 FACILITY ©O GASOLINE TRANSPORT IN DROP POSITION ©1 APPROACH (ENTRANCE OR EXIT) U.G. STORAGE TANKS _ ©3 PARKING SPACES 24 CONTROL CENTER 25 DOOR 6 ®6 WINDOWS Q SIGHT LINES 28 GASOLINE DISPENSER CONTROL CONSOLE EQUIPMENT WITH COMPLETE EQUIPMENT SHUTDOWN EMERGENCY MODE (U.L LISTED). ©9 MANUAL RELEASE LOCATED IN CONTROL CENTER CONVENIENT TO ATTENDANT. REMOTE RELEASE ENGINEERED BY FACTORY, INSTALLED BY AUTHORIZED FIRE SUPPRESSION CONTRACTOR. 30 CARD READER, CASH ACCEPTOR (MAY BE INSTALLED) L 0 C A L A P P R O V A L I. CHIEF OF DEPARTMENT OR HIS DESIGNEE, HAVE REVIEWED THE ATTACHED INFORMATION AND HAVE ACKNOWLEDGMENT THERE OF: CITY/TowN DATE F O R S T A T E U S E O N L Y I CERTIFY THAT I ELICITED THE VIEW OF THE FIRE CHIEF OR HIS DESIGNEE ON THIS PROPOSED SELF SERVE MOTOR FUEL FACILITY. NAME _ DATE -IRE PREVENTION ENGINEER DPS NAME OF SYSTEM P i RO CHEi'i103, INC. THE ATMNDANT 11 MEETS UL 1254 Hod®1 ATD-5180 CERT. COMP. NO. INSTALLER CERT. REG. NO. TYPE of FACILITY: REBUILD OF SELF SERVICE FACILITY NOTE: HOSE LENGTH FROM DISPENSER IS NOT TO EXCEED THE LIMIT OF SYSTEM PROTECTION WHICH COVERS THE HAZARD AREA. THIS SYSTEM DESIGN WAS BASED ON THE PYRO-CHEM TECHNICAL MANUAL DESIGN SECTION. PEROT IPLAH _ AM ENGNEERNG EDSQY DISCLAIMS ANY RESPONSIMITY FOR MONTOFM LYSPECTNG CBSERMGG OR SMVISNG - CONSIRUC101 SERYICES, OR THE LEANS, LERIDDs, SEMCES AND TEC1NIM OF CONSTRUCTION OR FOR JOB SITE SAFETY AND _ PROGRIYS FOR THE PROJECT DEIM BY THE FLANS FOR WHICH _. 1HS CERTIFUTICH 1S AJTDD:D. ATOIIB HAS NOT BEEN RETAINED FOR NOR SHALL R HANE ANY CONTROL. OVER OR BE IN CHARGE -- OF ACTS OR WS90HS aF ANY CONTRACTOR, AIBCaI1RACTOR, OTHER AGENTS OR DIPLOYEES OR OF ANY OTHER PERSONS -_ MOW PORTIONS OF THE MJRIC REFERENCE: PROPERTY LINES AND OTHER TOPOGRAPHIC INFORMATION AAI...AAA SHOWN ON THIS DRAWING WERE TAKEN FROM A PLAN ENTITLED:'E"rp�'A "TOPOGRAPHIC SURVEY 601 MAIN STREET, W. YARMOUTH, MA" N \ep t rtl PREPARED BY: OUTER LIMITS SURVEY, INC. CARVER, MA DATE NOV 8, 2001 ; SCALE: 1'=20' s MICALE � CIVIL S No.aola3 F.onMobll Fuels Marketing . CROM M Dwd YRl We9Nl°Y COWRIOHT©2002 E=ON MOBIL CORP, ALL RIGHTS RESER"ED O W Of a a W x a Z Li If 111: 0 MW eW LLj W W ¢ �< V) Z= — I- 7) iE 0 o e N d RAS Number `0 N F O O Z Z ¢N U i J ^ n Z W O Z U O W S ILI Jthx Z K F LLL (7 1- ILI U ED I - I- rl)O 2310Y < OD 0 c0 W n W x .. J ir In .4 W H- v I z L W W W Z ZW° x W DO 0_ 6i Design Type Building Type / Size; Building Style: wl Z 0 V) J LLI CL r� v J Bldg. Code: Scale: AS NOTED Drown By / Approved Sy, KEG File Name: 2932FS Dote: Issued For: 02/12/02 Project No. 2932 Drawing No. FS -1 SELF SERVO ISUND WARNING R IS UNLAWFUL AND DANGEROUS TO DISPENSE GASOUNE INTO UNAPPROVED CONTAINERS ... DWDIa FYELVAO OOTiRA.IOk BY ORDER OF STATE FIRE MARSHAL RED BACKGROUND W/WHITE MASKING SIGN SPECIFICATIONS DIMENSIONS: 12"X16" COLOR: WHITE BACKGROUND W/ RED MASKING SINGLE -SIDED DECAL APPLIED TO DISPENSER IN VISABLE LOCATION, LETTERING SIZE AND LOCATION SHALL BE AS SHOWN ABOVE. AVAILABLE FROM LOCAL PRINTER. DETAIL 1 SIGN NOT TO SCALE DETAIL 2 FOUR SIDES OF SELF SERVE AREAS). POSITIVE LIMITING BARRIER NOT TO SCALE DETAIL 3 NOZZLE AIMING POINTS NOT TO SCALE GENERAL NOTES (1) THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND THE PROPOSED NEW WORK. HE SHALL BE RESPONSIBLE FOR THE FIELD CONFIRMATION OF ALL ITEMS ON THE PLAN AND SHALL IMMEDIATELY NOTIFY THE OWNER IN WRITING OF ANY DISCREPANCY BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF THE ENTIRE SYSTEM AND SHALL COMPLY WITH THE REGULATIONS SET FORTH BY THE PREVAILING CODE AND THE REQUIREMENTS OF THE EQUIPMENT MANUFACTURER. (2) THE INSTALLATION OF THIS FIRE EXTINGUISHING SYSTEM MUST BE IN ACCORDANCE WITH THE PREVAILING MASSACHUSETTS CODE REQUIREMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD CONFIRMATION OF ALL ITEMS ON THE PLAN AND SHALL NOTIFY THE DESIGNER IN WRITING OF ANY DISCREPANCY IMMEDIATELY BEFORE PROCEEDING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF THE ENTIRE SYSTEM AND SHALL COMPLY WITH THE REGULATIONS SET FORTH BY THE PREVAILING MASSACHUSETTS CODE AND THE EQUIPMENT MANUFACTURER SPECIFICATIONS. (3) NO FIXED FIRE EXTINGUISHING SYSTEM WILL BE INSTALLED UNTIL AND ONLY AFTER THE DATE OF APPROVAL OF THE SELF-SERVICE MOTOR FUEL FACILITY. THE INSTALLATION SHALL BE TAKEN FROM AND IN ACCORDANCE WITH APPROVED STAMPED PLANS FROM THE STATE FIRE MARSHAL MARKED SUPPRESSION SYSTEM "INSTALLER COPY'. VIOLATION OF THIS STATEMENT WILL NULLIFY AND VOID THE APPROVAL OF THIS SELF-SERVICE APPLICATION. IF THE INSTALLATION OF THE SUPPRESSION SYSTEM OCCURS BEFORE THE STATE FIRE MARSHAL APPROVAL DATE, AND IS NOT TAKEN FROM THE APPROVED/STAMPED PLANS ISSUED BY THE FIRE MARSHAL'S OFFICE, IT SHALL BE AT THE EXPENSE AND PERIL OF THE LICENSEE. (4) THE FIXED FIRE EXTINGUISHING SYSTEM SHALL BE INSTALLED BY "FACTORY AUTHORIZED" PERSONNEL HAVING A CURRENT AND VALID "CERTIFICATE OF COMPETENCY" ISSUED BY THE COMMONWEALTH OF MASSACHUSETTS THROUGH THE STATE FIRE MARSHAL. EACH PERSON ENGAGED IN THE INSTALLATION, SERVICING, CHARGING, RECHARGING, REPAIR, TEST AND INSPECTION OF ENGINEERED OR PRE-ENGINEERED FIXED FIRE EXTINGUISHING SYSTEMS IN MASS. MUST HAVE A CERTIFICATE OF COMPETENCY ISSUED BY THE STATE FIRE MARSHAL OF THE DEPARTMENT OF PUBLIC SAFETY. MASSACHUSETTS FIRE PREVENTION RULE 527 CMR 23 REQUIRES EVERY PERSON HOLDING A VALID CERTIFICATE OF COMPETENCY, UPON DEMAND, SHOW AND PERMIT THE EXAMINATION OF SUCH CERTIFICATE BY THE MARSHAL,, HEAD OF THE FIRE DEPARTMENT, OR DESIGNEES. (5) THE DIKE, LOW HUMP, OR APPROVED STATE FIRE MARSHAL POSITIVE LIMITING BARRIER MAY BE INSTALLED AT ANY TIME. (6) THE LICENSED INSTALLING CONTRACTOR SHALL INSURE THAT THE LIMITS OF THE FIRE SUPPRESSION SYSTEM ARE NOT EXCEEDED. (7) THE INSTALLING CONTRACTOR SHALL TEST FIRE THE ENTIRE SYSTEM, INCLUDING ALL CONTROLS AND SHALL CERTIFY TO THE OWNER IN WRITING OF THE SYSTEM'S SATISFACTORY OPERATIONAL PERFORMANCE AND COMPLIANCE WITH U.L. APPROVAL. (8) ATSEMIANNALLY, ALLHEAL ECTORS,UETC. SHALLDIBE INSPECTED BY APPROVED AND CERTSCHARGE NOZZLES, PIPINDRY IFIED COMPANIES WITH A VALID MASSACHUSETTS ISSUED CERTIFICATE OF REGISTRATION UNDER 527 CMR 23.00, COMPANY TYPES B & C (43&44) AND INDIVIDUAL TYPES F & G (47&48). THE REPORTS OF SUCH INSPECTIONS SHALL BE SUBMITTED TO THE HEAD OF THE FIRE DEPARTMENT IN ACCORDANCE WITH NFPA STANDARDS (NFPA-17, 1994 EDITION). (9) EXISTING SELF SERVICE FACILITIES SHALL BE SUBJECTED TO RESUBMITTAL AND REVIEW SHOULD ANY OF THE FOLLOWING ITEMS OCCUR: (A) METHOD OF DISPENSING MOTOR FUEL. (B) ALTERATIONS TO THE PRE-ENGINEERED FIXED EXTINGUISHING SYSTEM(S) OTHER THAN NORMAL MAINTENANCE PROCEDURES. (C) ALTERATIONS TO THE SELF SERVICE DISPENSING ISLAND ARRANGEMENT(S) RESULTING IN A CHANCE OF HAZARD AREA PROTECTION, (0) ALTERATIONS OR ENVIRONMENTAL CHANGES RESULTING IN THE INABILITY OF A CONSOLE OPERATOR TO CONSTANTLY OBSERVE THE DISPENSING OPERATION. THIS ITEM SHALL BE DETERMINED BY THE LOCAL HEAD OF FIRE DEPARTMENT. (10) EXISTING AND NEW UNDERGROUND TANKS FOR THE PROPOSED FACILITY SHALL BE REGISTERED WITH THE STATE FIRE MARSHAL'S OFFICE (FORM F.P. 290). THIS FORM SHALL BE SUBMITTED FOR EACH TANK WITH THE SUBMITTAL PACKAGE. EACH TANK SHALL BE ALPHABETICALLY OR NUMERICALLY CODED AND DULY NOTED ON THE SITE PLAN. (11) PRODUCT PIPING SHALL MEET THE MATERIAL AND INSTALLATION STANDARDS SET FORTH IN THE 527 CMR 9. (12) THE CONTROLLING MECHANISM CONSOLE SHALL INCLUDE A DISCONNECT SWITCH WHICH WILL INSTANTLY CUT OFF ALL PUMPING POWER TO ALL MOTOR FUEL PUMPS AT THE SERVICE STATION. THE CONTROLLING MECHANISM CONSOLE, SWITCHES AND RELATED EQUIPMENT SHALL BE OF A DESIGN AND TYPE APPROVED BY THE FIRE MARSHAL AND SHALL BE UNDERWRITERS LABORATORIES (U.L.) LISTED EQUIPMENT. (13) THE POSITIVE LIMITING BARRIER TO BE CONTINUOUS SQUARE OR "V" GROOVE 3/4 X3/4" DEEP ON 4 314" CENTERS WITH CROSS INTERCONNECTING GROOVES EITHER SQUARE OR "V GROOVES EQUALLY SPACED ON MIN. 12" MAX. 46" CENTERS. THE OUTSIDE GROOVES TO BE AT LIMIT OF HAZARD PROTECTION AREA AND THE POTENTIAL SPILL AREA TO BE WITHIN THIS PROTECTION AREA. GROOVES MAY BE SAW CUT OR SCORED INTO CONCRETE MAT. GROOVES MUST BE KEPT CLEAN AT ALL TIMES (SEE DETAIL LEFT). THE POSITIVE LIMITING BARRIER SHALL BE 10'-0" MAXIMUM DISTANCE FROM CENTER LINE OF DISPENSER. CONTRACTOR SHALL FIELD ADJUST POSITIVE LIMITING BARRIER TO CLEAR ALL MANHOLES AND/OR OPENINGS WITHIN THE POSITIVE LIMITING BARRIER OR MODIFY ALL SUCH MANHOLES AS REQUIRED WITH ELEVATED, BOLTED AND GASKETED COVERS. (14) NOZZLE AND HOSE FROM EACH PETROLEUM PRODUCT DISPENSER SHALL NOT EXTEND BEYOND POSITIVE LIMITING BARRIER AND NO PETROLEUM PRODUCT SHALL BE DISPENSED BEYOND POSITIVE LIMITING BARRIER. USE OF ANY "HOLD OPEN CLIPS" ON SELF SERVE DISPENSERS IS PROHIBITED EXCEPT WHERE U.L. LISTED STAGE 11 VAPOR RECOVERY NOZZLES ARE USED WHICH WILL AUTOMATICALLY SHUT OFF IF THE NOZZLE IS REMOVED FROM THE FILL PIPE. (15) STATE FIRE MARSHAL APPROVED SIGNS SHALL BE INSTALLED TO BE VISIBLE FROM BOTH ENDS OF A SELF SERVE DISPENSING ISLAND. (SEE DETAIL 1) (16) MOUNT 2 SIGNS AT CONSOLE IN OPERATOR'S FULL VIEW: A. "DO NOT ENERGIZE PUMPS UNLESS VEHICLE ENGINE IS SHUT OFF AND PEOPLE ARE NOT SMOKING." S. "IN CASE OF FIRE, PULL EMERGENCY SWITCH FOR SYSTEM ACTIVATION, THEN CALL THE FIRE DEPARTMENT." (17) IF CARD READING DEVICES OR CASH RECEPTORS ARE INSTALLED AT THIS FACILITY; THEY SHALL BE SUBJECT TO THE FOLLOWING CONDITIONS: A. THE AUTOMATIC CREDIT CARD OR CASHING READING DEVICE SHALL NOT BE USED AS PHYSICAL AUTHORIZATION FOR THE DISPENSING OF GASOLINE, BUT RATHER EACH SALE SHALL BE INDIVIDUALLY AUTHORIZED BY THE SELF SERVE ATTENDANT. B. THE SELF SERVE FACILITY MEETS ALL OTHER APPLICABLE PROVISIONS. (18) A MENS SHALL BE PROVIDED FOR THE CONTROLLING MECHANISM CONSOLE OPERATOR TO OBSERVE THE FILLING OPERATION AT EACH VEHICLE AND THE DISPENSING OF MOTOR FUEL SHALL BE CONTINUOUSLY OBSERVED BY THE CONSOLE OPERATOR DURING THE TIME THAT ANY OF THE PUMPS HAVE BEEN ACTIVATED TO DISPENSE MOTOR FUEL. CONSTANT CONTACT BETWEEN THE CONSOLE OPERATOR AND THE DISPENSING ISLAND BY MEANS OF AN INTERCOMMUNICATIONS SYSTEM SHALL BE MAINTAINED. (19) UNRELATED BUSINESS: VENDING AREAS, CONVENIENCE FOOD MART, AUTOMOTIVE REPAIR GARAGE, AND SIMILAR BUSINESS SHALL BE OPERATED BY OTHERS. EXCEPTION: FACILITIES OF 1,000 S.F. OR LESS OF RETAIL SALES AREA AND EIGHT OR LESS FUELING POSITIONS MAY BE OPERATED BY ONE ATTENDANT AT THE DISCRETION OF THE HEAD OF THE FIRE DEPARTMENT. (20) ALL DISCHARGE PIPING, TEES, ELBOWS UNIONS AND FITTINGS THAT ARE PART OF THE DISTRIBUTION SYSTEM OF THE DRY CHEMICAL PRE-ENGINEERED FIXED FIRE EXTINGUISHING SYSTEM AT SELF SERVE MODE MOTOR FUEL FACILITIES SWILL BE SCHEDULE 40 THREADED GALVANIZED STEEL PIPE. VEHICLE CAPACITY FUELING WAITING TO BE FUELEDPARKING TOTAL SELF SERVICE 16 8 19 43 FULL SERVICE ISLAND I STANDARD I END I TOTAL PER ISL. 4 0 2r-0" 4 m/ 24 Momrs 1 2 en./ 12 mmss 6 cm, 36 No2ars TOTAL AT FACILITY = 24 en✓ 144 Names LEGEND 10 160' AUTOMATIC THERMOSTAT INTERCONNECTED TO FIRE SUPPRESSION SYSTEM INSTALLED ON 15 FOOT MAXIMUM CENTERS IN A SINGLE LINE OVER THE CENTER OF THE ISLAND. IF THERE IS A CANOPY OVER THE ISLAND, THE DETECTOR SHALL BE MOUNTED ON ITS UNDER SURFACE, PROVIDING THE HEIGHT DOES NOT EXCEED 15 FEET ABOVE THE ROADBED. IF THERE IS NO CANOPY THE DETECTOR SHALL BE LOCATED NO HIGHER THAN THE NOZZLES AND MOUNTED ON THE UNDER SURFACE OF AN 187r18"x2" HEAT COLLECTOR. O2 CURVED MIRRORS OR C.C.T.V. CAMERAS AND MONITORS WHERE REQUIRED. O INTERCOM SPEAKERS AT EACH COLUMN OR DISPENSER WITH MASTER CONTROL LOCATED AT CENTRAL AREA. O DRY CHEMICAL CYLINDERS AS REQUIRED BY MANUFACTURER OF SUPPRESSION SYSTEM WITH REFERENCE TO U/L APPROVED INSTALLATION AND MAINTENANCE MANUAL. O5OVERHEAD FIRE SUPPRESSION PIPING TO BE CALV. SCH. 401 (DISTRIBUTION AND SUPPLY), © NOZZLE O7 NO SMOKING TURN OFF ENGINE SIGN - 12" X 16" - SINGLE -SIDED DECAL APPLIED TO DISPENSER IN VISIBLE LOCATION. LETTERING SIZE AND LOCATION SHALL BE AS DETAIL 1. OS HAND OPERATED 10f BC FIRE EXTINGUISHER. 90 FIRE SUPPRESSION STRIKE POINT. 70 COLUMN OR LIGHT POLE 11 GASOLINE DISPENSING PUMP U/L APPROVED 12 POSITIVE LIMITING BARRIER AROUND PERIMETER OF SELF SERVE GASOLINE DISPENSING AREA. 13 SELF SERVE GASOLINE DISPENSING AREA, 14 APPROPRIATE INSTRUCTIONS FOR USE AT EACH SELF SERVE DISPENSER 15 DIRECTION OF TRAFFIC & "NO PARKING" PAINTED ON PAVEMENT (WHERE REQUIRED) 16 SAFETY BARRICADE 17 LIGHTING WITHIN SELF SERVE DISPENSING AREA 0 18 CONCRETE MAT (IS GENERALLY LEVEL) 19 FACILITY ©O GASOLINE TRANSPORT IN DROP POSITION ©1 APPROACH (ENTRANCE OR EXIT) U.G. STORAGE TANKS _ ©3 PARKING SPACES 24 CONTROL CENTER 25 DOOR 6 ®6 WINDOWS Q SIGHT LINES 28 GASOLINE DISPENSER CONTROL CONSOLE EQUIPMENT WITH COMPLETE EQUIPMENT SHUTDOWN EMERGENCY MODE (U.L LISTED). ©9 MANUAL RELEASE LOCATED IN CONTROL CENTER CONVENIENT TO ATTENDANT. REMOTE RELEASE ENGINEERED BY FACTORY, INSTALLED BY AUTHORIZED FIRE SUPPRESSION CONTRACTOR. 30 CARD READER, CASH ACCEPTOR (MAY BE INSTALLED) L 0 C A L A P P R O V A L I. CHIEF OF DEPARTMENT OR HIS DESIGNEE, HAVE REVIEWED THE ATTACHED INFORMATION AND HAVE ACKNOWLEDGMENT THERE OF: CITY/TowN DATE F O R S T A T E U S E O N L Y I CERTIFY THAT I ELICITED THE VIEW OF THE FIRE CHIEF OR HIS DESIGNEE ON THIS PROPOSED SELF SERVE MOTOR FUEL FACILITY. NAME _ DATE -IRE PREVENTION ENGINEER DPS NAME OF SYSTEM P i RO CHEi'i103, INC. THE ATMNDANT 11 MEETS UL 1254 Hod®1 ATD-5180 CERT. COMP. NO. INSTALLER CERT. REG. NO. TYPE of FACILITY: REBUILD OF SELF SERVICE FACILITY NOTE: HOSE LENGTH FROM DISPENSER IS NOT TO EXCEED THE LIMIT OF SYSTEM PROTECTION WHICH COVERS THE HAZARD AREA. THIS SYSTEM DESIGN WAS BASED ON THE PYRO-CHEM TECHNICAL MANUAL DESIGN SECTION. PEROT IPLAH _ AM ENGNEERNG EDSQY DISCLAIMS ANY RESPONSIMITY FOR MONTOFM LYSPECTNG CBSERMGG OR SMVISNG - CONSIRUC101 SERYICES, OR THE LEANS, LERIDDs, SEMCES AND TEC1NIM OF CONSTRUCTION OR FOR JOB SITE SAFETY AND _ PROGRIYS FOR THE PROJECT DEIM BY THE FLANS FOR WHICH _. 1HS CERTIFUTICH 1S AJTDD:D. ATOIIB HAS NOT BEEN RETAINED FOR NOR SHALL R HANE ANY CONTROL. OVER OR BE IN CHARGE -- OF ACTS OR WS90HS aF ANY CONTRACTOR, AIBCaI1RACTOR, OTHER AGENTS OR DIPLOYEES OR OF ANY OTHER PERSONS -_ MOW PORTIONS OF THE MJRIC REFERENCE: PROPERTY LINES AND OTHER TOPOGRAPHIC INFORMATION AAI...AAA SHOWN ON THIS DRAWING WERE TAKEN FROM A PLAN ENTITLED:'E"rp�'A "TOPOGRAPHIC SURVEY 601 MAIN STREET, W. YARMOUTH, MA" N \ep t rtl PREPARED BY: OUTER LIMITS SURVEY, INC. CARVER, MA DATE NOV 8, 2001 ; SCALE: 1'=20' s MICALE � CIVIL S No.aola3 F.onMobll Fuels Marketing . CROM M Dwd YRl We9Nl°Y COWRIOHT©2002 E=ON MOBIL CORP, ALL RIGHTS RESER"ED O W Of a a W x a Z Li If 111: 0 MW eW LLj W W ¢ �< V) Z= — I- 7) iE 0 o e N d RAS Number `0 N F O O Z Z ¢N U i J ^ n Z W O Z U O W S ILI Jthx Z K F LLL (7 1- ILI U ED I - I- rl)O 2310Y < OD 0 c0 W n W x .. J ir In .4 W H- v I z L W W W Z ZW° x W DO 0_ 6i Design Type Building Type / Size; Building Style: wl Z 0 V) J LLI CL r� v J Bldg. Code: Scale: AS NOTED Drown By / Approved Sy, KEG File Name: 2932FS Dote: Issued For: 02/12/02 Project No. 2932 Drawing No. FS -1