Loading...
HomeMy WebLinkAboutDecision 4058 - K - C-3 Utility PlanxC.BASIN BRIM 11.6 3 � am MH IM 11.54 C.BASIN RIM 11.5 w-, VG AREA CRp»„i O � a C.BASIN a1 -1-L 4 1 1 i e x 1 � � N m x 1 ° C.Bi 1 � 1 1 1 DATA (SEE SHEET C-8 FOR DETAILS) TITLE V DESIGN FLOW- (10,000 SF. RETAIL 0 1 500 GPD / m v 1 1 TRENCH 0.74 GPD 1�= .74 GAL/SF) / E Pq 135 FT. 1 v] 1 SOIL PERC RATE 1 I( OBSERVED GROUNDWATER ELEVATION N 14.6 FT ADJUSTED USGS GROUNDWATER ELEVATION m 16.1 FT GREASE TRAP REQUIREMENT (TITLE V) ° > aW / SEPTIC TANK (TITLE V) 1,500 GAL SEPTIC TANK PROPOSED W m 1,500 GAL ai • L Z ° 3 _ J 000 LL IL SIDEWALK TL C. BASIN 0� < CL RIM 10.72 5 0m (D = a0ro � w v 6" C.I. WATER MAIN d N 10" C.1., WATER MAIN w r w ° 0.57 FATE LAYOUT a_ xC.BASIN BRIM 11.6 3 � am MH IM 11.54 C.BASIN RIM 11.5 w-, VG AREA CRp»„i O � a C.BASIN a1 -1-L 4 1 1 i e x 1 � � N m x 1 ° C.Bi 1 � 1 1 1 DATA (SEE SHEET C-8 FOR DETAILS) TITLE V DESIGN FLOW- (10,000 SF. RETAIL 0 1 500 GPD PROPOSED SYSTEM CAPACITY (TITLE V) 4 1 1 TRENCH 0.74 GPD 1�= .74 GAL/SF) 3.70 GLF REQUIRED TRENCH LENGTH (500/3.70) Pq 135 FT. 1 v] 1 SOIL PERC RATE 1 ` OBSERVED GROUNDWATER ELEVATION N 14.6 FT ADJUSTED USGS GROUNDWATER ELEVATION m 16.1 FT GREASE TRAP REQUIREMENT (TITLE V) ° > aW �1 r . 10 20 40 .mom TL (TRAFFIC LIGHT) STUB OF OLD TRAFFIC LIGHT TRAFFIC /-CONTROL BOX LIMITS OF 1997 TOWN ALTERATION AND LIMITS OF 1997 STATE HIGHWAY LAYOUT - 7338 `- UPLT - - anv- 3 ---------- FOREST ROACH .S2 w - _ 221' " _ " W_ wLJ. WA ILH MAIN ° w w w w w--__ N5912'18"W �1 N59'28'17"W UPL ^-�6 H8-620-0-0 ❑�❑ 12.35 �� ® INSTALL GOOSE °.C.BASIN D • W t1 RIM 11.24 a- Z m Z _ HB -5 > LP (TYP.) 7 SEE NOTE 20/UTILITY NOTE I r SHEET CO.2 a +B-3 I 4" PVC HB -2 1=12.60 OBSERVATION PORT �HB R=16.11 eSUBSURFACE I I I I SEPTIC DISPOSAL I I I I TP#1 C-8 FIELD II II LEACHING TRENCHES II 68LF, S=0.5% RESERVEI I I I AREA (T(P) HB II 3 I I I 13 II 4" PVC I I I 1=12.91 CONCRETE D -BOX TRANSFORMER PAD R=15.50 SEE NOTE 19/UTIUIY NOTE 1=13.09(4"PVC)IN UU SHEET CO.2 1=12.92(40PVC)OUT � RIM lk 000 1 � i5TA4� �1 # C.BASIN " RIM 9.96 it N YARMOUTH BAY ASSOC. LTD. INC. #1029 ROUTE 28 PLAN BOOK 199/69 )EEO BOOK 4556/107 ASSESSORS MAP 50 PARCEL 185 "BANK' • AL ENT ENT 4" PVC 4LF S=1% 4" PVC 2LF S=t' 4" PVC SEWER 1=13.40 (STUB) 1=13.50 (BLDG) 1,500 GAL SEPTIC TANK R=15.72 1=13.38 (4" PVC) IN 1=13.13 (4' PVC) OUT PLAN 301, PAGE 45 DEED 1353/15 ASSESSORS MAP 50 PARCEL 117.1 LIMITS OF 1997 ROAD WIDENING - an, arw - m 6" TS&V --1 (PUBLIC - VARIABLE WIDTH) (20' WIDE BIT. PAVEMENT) _ 93.64' 60 _ N'33'46"W PROPOSED WALGREENS 9,996 S.F. FF=16.5± FIRE DEPT. CONNECTION - �! A5 A2 33.71 60.00', / ' S71 'i N/F YARMOUTH BAY ASSOC LTD. INC. OFF ROUTE 28 PLAN BOOK 91/15, F1 DEED 600K 4556/107 \ ASSESSORS MAP 50 PARCEL 173 SEPTIC SYSTEM DESIGN DATA (SEE SHEET C-8 FOR DETAILS) TITLE V DESIGN FLOW- (10,000 SF. RETAIL 0 50 GPD/KSF) 500 GPD PROPOSED SYSTEM CAPACITY (TITLE V) [:)ISSUED 500 GPD o TRENCH 0.74 GPD 14 .74 GAL/SF) 3.70 GLF REQUIRED TRENCH LENGTH (500/3.70) Pq 135 FT. TRENCH LENGTH PROVIDED (2 ® 68 FT.) v] 136 FT. SOIL PERC RATE C ` OBSERVED GROUNDWATER ELEVATION N 14.6 FT ADJUSTED USGS GROUNDWATER ELEVATION m 16.1 FT GREASE TRAP REQUIREMENT (TITLE V) ° > aW NONE AL ENT ENT 4" PVC 4LF S=1% 4" PVC 2LF S=t' 4" PVC SEWER 1=13.40 (STUB) 1=13.50 (BLDG) 1,500 GAL SEPTIC TANK R=15.72 1=13.38 (4" PVC) IN 1=13.13 (4' PVC) OUT PLAN 301, PAGE 45 DEED 1353/15 ASSESSORS MAP 50 PARCEL 117.1 LIMITS OF 1997 ROAD WIDENING - an, arw - m 6" TS&V --1 (PUBLIC - VARIABLE WIDTH) (20' WIDE BIT. PAVEMENT) _ 93.64' 60 _ N'33'46"W PROPOSED WALGREENS 9,996 S.F. FF=16.5± FIRE DEPT. CONNECTION - �! A5 A2 33.71 60.00', / ' S71 'i N/F YARMOUTH BAY ASSOC LTD. INC. OFF ROUTE 28 PLAN BOOK 91/15, F1 DEED 600K 4556/107 \ ASSESSORS MAP 50 PARCEL 173 SEPTIC SYSTEM DESIGN DATA (SEE SHEET C-8 FOR DETAILS) TITLE V DESIGN FLOW- (10,000 SF. RETAIL 0 50 GPD/KSF) 500 GPD PROPOSED SYSTEM CAPACITY (TITLE V) [:)ISSUED 500 GPD ALLOWABLE ABSORPTION RATE PER SQ. FT. OF TRENCH 0.74 GPD TRENCH CAPACITY PER LINEAR FOOT (5 S.F. 0 .74 GAL/SF) 3.70 GLF REQUIRED TRENCH LENGTH (500/3.70) Pq 135 FT. TRENCH LENGTH PROVIDED (2 ® 68 FT.) v] 136 FT. SOIL PERC RATE ° CO 2 MIN./INCH OBSERVED GROUNDWATER ELEVATION N 14.6 FT ADJUSTED USGS GROUNDWATER ELEVATION m 16.1 FT GREASE TRAP REQUIREMENT (TITLE V) ° > aW NONE SEPTIC TANK (TITLE V) 1,500 GAL SEPTIC TANK PROPOSED W m 1,500 GAL I 111067 ROUTE 28 I PLAN BOOK 301, PAGE 45 DEED BOOK 1353, PAGE 15 I ASSESSORS MAP 50 I PARCEL 116 HYDRANT TAG BOLT ELEV. 21.24 ' (NO 1929) I I (FMLY OQ fOWN ROAD, •� CS&B x • o� � WOODED a� -PROPOSED f♦ c < FIRE HYDRA 1 It 1 #25 EXISTING WELL HAND PUMP N 1 O 1 O S. T. N/F S o. 1 PETER IGOE . . ' f♦ #25 FOREST ROAD PLAN BOOK 95/63 • DEED BOOK 18001/T99 ASSESSORS MAP 50 k� PARCEL 177 APPROX. LOCATION OF PROP. GAS SERVICE, FINAL SIZE �.• ` AND LOCATION T.B.O. BY GAS I • CO. (TYP) SEE NOTE v• i 15/UTILITY NOTES SHED e. ZZ a .� ��.: °• WOODED r \ •:v: Z .. v D > #2 (TYP) 1'00 N 1 i r i NIF JAMES & RHONDA LOFRANCE #36 OLD MAIN STREET PLAN BOOK 337/5 DEED BOOK 8257/119 ASSESSORS MAP 50 PARCEL 174 L.P. \ } TEST PIT & PERC TEST PIT NIF RICHARD & ELIZABETH NE/7-.e #50 OLD MAIN STREET PLAN BOOK 337, PAGE 5 DEED BOOK 4045, PAGE 316 ASSESSORS MAP 50 PARCEL 175 "VACANT LAND" WOODED HYDR TAG 1 ELEV. (NGV CONTRACTOR SHALL REFER TO ARCH. PLANS FOR EXACT DIMENSIONS, LOCATIONS AND DETAILS OF EXIT PORCHES, VESTIBULES, RAMPS, LOADING AREA, BUILDING DIMENSIONS, BUILDING UTILITY ENT. LOCATIONS, DUMPSTER AREAS, BOLLARDS, TRANSFORMER AND GENERATOR PADS, ETC. ®NOT FOR CONSTRUCTION [-]ISSUED FOR REVIEW ®ISSUED FOR PERMIT [:)ISSUED FOR BID/PRICING ❑ ISSUED FOR CONSTRUCTION DD^o FLANAGAN CIVIL Flo.35110 - NOTE: SEE DWG. CO.2 FOR PLAN NOTES Copyright c 2000 by Carter & Burgess, Inc PREPARED FOR: 0 � N co tfJ ca lf] 0 rd.. DAF MD SCALE: O O rn Z kn PREPARED FOR: C\p � N co tfJ ca lf] m M rd.. DAF MD SCALE: O O rn kn Pq V W to N v] HvQ ° CO c; N �VN Cr N m W O aoao ° > aW ti Z W m tL ai • L Z ° 3 _ J 000 LL IL c �rnww1� O 0� < CL Vr 5 0m (D = a0ro � K = 3 d N ow 0 = o a o FIT,I I z PREPARED FOR: BY: U � O O � O z DAF MD SCALE: O O rn kn Pq V W to N v] PREPARaEDD BY: DRAWN BY: RGP N DAF MD SCALE: O O DATE: 2/3/2006 Col L U V W to N Q HvQ ° CO c; N �VN E `aw0' m W O aoao ° > aW w ag¢ W m tL ai • L Z ° 3 _ J 000 LL IL c �rnww1� O 0� < CL Vr 5 0m (D = a0ro DESIGNED BY: SXS DRAWN BY: RGP CHECKED BY: DAF MD SCALE: 1 "=20' DATE: 2/3/2006 J Z W CL 0 _ J IL O CL DRAWING NO. 0=3 PROJECT NO. 305517