HomeMy WebLinkAboutEngineered Plans - 2015LEGEND
PROPOSED CONTOUR
9® PROPOSED SPOT GRADE
--98-- EXISTING CONTOUR
+ 96.52 EXISTING SPOT GRADE
W— EXISTING WATER SERVICE
TEST PIT
a
0 0!4
r
r
33.
i 32.8 0
r
i
CESSI
OF _ r
FLOOR PLAN
32
32
SCALE: 1"=20'
WEST YARMOUTH
R� 29
G3g@gVGD
Std' 2 9 2015
HEALTH DEPT.
LOCUS MAP
LOCUS INFORMATION
TITLE REF: BK 11761 PG 015
PARCEL ID: MAP 030 PAR. 227
LOT SIZE: 0.29 ACRES
Q
3 -
SEPTIC SYSTEM
REPAIR PLAN
LOCATED AT:
14 THOMAS PATH
WEST YARMOUTH, MA
PREPARED FOR
PICKFORD
SEPTEMBER 27, 2015
OF Mgss9�yG
o D R M.
o. Y40
sl
MEYER
MEYER & SONS, INC.
P.O. BOX 981
EAST SANDWICH, MA. 02537
PH: (508)360-3311
FAX: (774)413-9468
meyerandsonstitle54gmail.com
www.meyerandsons.com
SHEET 1 OF 2 J##1744
NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS
T.O.F. EL.=35.0± SEPTIC TANK PROPOSED D -BOX
INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER
OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE
/-F.G. EL.=32.4± /-F.G. EL.=31.7± /-F.G. EL: 31.0±
9" MIN COVER/
36" MAX COVER L = 30'
® S=t% (MIN.) EL. = 30.95 0 S=1% (MIN.)
4"SCH40 PVC 4"SCH40 PVC
10'1
\INV.=29.90 ta-
48" LIQUID INV.=29.65
LEVEL
GAS BAFFLE
,
INV.=29.25)
PROPOSED 1.500 GALLON SEPTIC TANK
EXIST. SEWER OUTLET
INV.=31.92
NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING
PIPE INVERTS PRIOR TO CONSTRUCTION
2) TANK AND D -BOX SHALL BE SET LEVEL AND
TRUE TO GRADE ON A MECHANICALLY COMPACTED
SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN
310 CMR 15.221(2)
3) INSTALL INLET & OUTLET TEES W/
GAS BAFFLE AS REQUIRED
PROPOSED
D -BOX
DB -5
H 0
0 S=1% ((M N.)
4"SCH40 PVC
INVERT
INV.=28.98 -
INV.=29.08
BREAKOUT=TOP ELEV.=29.37
INV. ELEV.= 28.98
BOTTOM ELEV.= 28.70
NOTE: TO PREVENT BREAKOUT, THE PROPOSED
FINISH GRADE SHALL NOT BE < EL:29.37
FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S.
PROPOSED S.A.S.
INSTALL A 4" DIAMETER INSPECTION PORT OVER
ONE CHAMBER (MIN.) AND SET TO 3" OF F.G.
/-F.G. EL: 31.0(MAX.)
5' MIN. ABOVE BOTTOM OF
T.P. EXCAVATION OR G.W.
(7.56' PROVIDED)
BOTTOM OF TESTHOLE: EL:23.65 -
SEPTIC SYSTEM PROFILE
N.T.S.
DESIGN CRITERIA **PROP NOT IN ZONE II**
NUMBER OF BEDROOMS: 2 BEDROOM DWELLING/3 BEDROOM DESIGN
DESIGN FLOW: RESIDENTIAL: 3 BEDROOMS ® 110 GPD/BR = 330 GPD
DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF)
GARBAGE GRINDER: NO (not designed for garbage grinder)
DISTRIBUTION BOX: USE DB -5 (H20) -
SEPTIC TANK: 330 gpd x 200% = 660 gpd USE NEW 1,50OG SEPTIC TANK
e LEACHING AREA REQUIRED: (330)/.74 = 445.94 S.F.
PRIMARY S.A.S.
USE 4 ROWS OF _ 6_ -_ INFILTRATOR QUICK 4_ STD LP (3.3" INVERT
UNITS WITH NO STONE
BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER)
(CHAMBER UNITS) 24 UNITS x 4.00 LF x 4.73 SF/LF = 454.08 SF
TOTAL AREA = 454.08 SF
DESIGN FLOW PROVIDED: 0.74GPD/SF(454.08SF) = 336 GPD > 330 GPD req'd
INSTALL TWO INSPECTION PORTS (MIN.)
4 ROWS OF 6 UNITS AT 4'/UNIT = 24'/ROW
SOIL ABSORPTION SYSTEM (PROFILE)
RESTORE VEGETATIVE COVER
-BACKFILL WITH CLEAN PERC SAND
TO TOP OF CHAMBERS
2.83'
EXISTING SUITABLE
MATERIAL
EFFECTIVE WIDTH = 4 x 2.83' = 11.32'1
USE 4 ROWS OF 6 INFILTRATOR QUICK 4 PLUS
STD LP (3.3" INVERT) UNITS -NO STONE
TYPICAL SECTION
wrs.
SOIL LOGS
ADJUSTED GROUNDWATER MEDIUM
PERC TEST SAND
WELL: MIW-29 ZONE: B 0 27.07 2.5Y 6/4
LEVEL: 9.2 ADJUSTMENT: 3.5'
OBS GRNDWATER 0 135" EL. 20.15
ADJUSTED GROUNDWATER EL. 23.65 20.07 136"
PERC RATE <2 MIN/IN. ("Cl" HORIZON)
NO GROUNDWATER OBSERVED
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. DWELLING IS SERVICED BY MUNICIPAL WATER.
8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED
TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR.
9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK.
10. EXISTING LEACH PIT TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5.
11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION
12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY
AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY
13. NO KNOWN PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING
14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. )
15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW
FOR THE USE OF A GARBAGE GRINDER.
16. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING
SECTION
3 3"
INVERT
HEIGHT
INFILTRATOR - QUICK 4LP
END CAP
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
14 THOMAS PATH, WEST YARMOUTH, MA
Prepared for: Pickford
System Design and Site Plan by: SCALE DRAWN DATE
MEYER &SONS, INC. N.T.S. DMM 09/27/1
I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 PO BOX 981 CHECKED SHEET N0.
to conduct soil evaluations and that the above analysis has been performed by me consistent with the EAST SANDWICH, MA 02537
requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999. 506-3622922 DMM 2 Of 2
DATE:
SEPTEMBER
17, 2015
OF yqs
SOIL
EVALUATOR:
DARREN M.
MEYER, RS, CSE 1614
S941,
WITNESS:
AMY VONHONE, YARMOUTH HEALTH
DARREN M.
AM
N
TP -1
Depth
4
Elegy.
1Av��
31.40
A
0"
�
LOAMY SAND
10YR 4/1
SO ITAR�a�
30.07
16"
t `
l
B
LOAMY SAND
t 0YR 6/6
28.07
40"
ADJUSTED GROUNDWATER MEDIUM
PERC TEST SAND
WELL: MIW-29 ZONE: B 0 27.07 2.5Y 6/4
LEVEL: 9.2 ADJUSTMENT: 3.5'
OBS GRNDWATER 0 135" EL. 20.15
ADJUSTED GROUNDWATER EL. 23.65 20.07 136"
PERC RATE <2 MIN/IN. ("Cl" HORIZON)
NO GROUNDWATER OBSERVED
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. DWELLING IS SERVICED BY MUNICIPAL WATER.
8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED
TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR.
9. R SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK.
10. EXISTING LEACH PIT TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5.
11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION
12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY
AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY
13. NO KNOWN PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING
14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. )
15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW
FOR THE USE OF A GARBAGE GRINDER.
16. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING
SECTION
3 3"
INVERT
HEIGHT
INFILTRATOR - QUICK 4LP
END CAP
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
14 THOMAS PATH, WEST YARMOUTH, MA
Prepared for: Pickford
System Design and Site Plan by: SCALE DRAWN DATE
MEYER &SONS, INC. N.T.S. DMM 09/27/1
I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 PO BOX 981 CHECKED SHEET N0.
to conduct soil evaluations and that the above analysis has been performed by me consistent with the EAST SANDWICH, MA 02537
requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999. 506-3622922 DMM 2 Of 2