Loading...
HomeMy WebLinkAboutEngineered Plans - 201511. Wells not shown exceed 150' from the DrODosed SAS CUL TEC RECHARGER I8OHD 2 -COLUMNS OF 5 - UNITS LOCUS BENCHMARK:.EL. 50.63 LOCUS ASSUMED DATUM - INSPECTION PORTS ON CENTER UNITS ST T. 0. DOOR THRESHOLD �oPo gr�oti DIST. Boxq�FN� DB-JIH-10 PROPOSED SEPTIC TANK HAzeLMooR F 1500 -GALLON (H -IO) CVV BR -I BR -2 JOYCE ST m yrs oQ,� cn o N_--•-- / y rn 1" = 20' r7 0 0 l✓ ~ip Po STILES RD Cn m �o MAG NAIL SET EL. 49.58 �,>. �.,::�� BATH X LIVING o ' ROOM 9.0 sO ( 50.71 BR -3 7 ^I Ngp'24 30„E' ` x 50.53 BSORP ION SYSTEM DETAIL ' CA' EAT IN SOIL A T 119 83 c,a ” KITCHEN LEGEND H OF s RICHARD J. JUDD. JR_ s4 IT 1 0 Moran Engineering Associates, LLC LAWN AREA ; - 50.53 k� � l� 50.42 H 18.5, t TEST HOLE 49.39 W/IRRIGATION OH 50:45 G STAIRS TO t STAIRS CELLAR It�>> EXISTING CESSPOOL(S) GARAGE ���� .LOT A % 10' ® LAUNDRY _E; "D" BOX fl, 980.70 S.F. 0.275 ACRES I 7(111 I I I I I I I tx FLOOR PLAN PROPOSED SEPTIC TANK C/0 ® �\ 50.21 IImII l l X11 �� NOT TO SCALE 1n, ' 50.11 X FENCE LINE 1 <I I �I x p d OS ImI m Iml _ _ - - -50 EXISTING CONTOUR EX (STING 25.0' ISI IV, - p OH OVER -HEAD UTILITIES y iNG O.F.50,65 50.36 I I 50.23 hI r " PROPOSED VENT W/ W WATER LINE 0 m Q T i LAWN AREA 11 I } CHARCOAL FILTER G UNDERGROUND GAS l=S o 0 " W/IRRIGATION ISI ` t 1 X` Lot c °� o SITE AND SEWAGE PLAN y C', O I m 3 50 20 ( 49.88 �X I% x LOCUS: y 3 L L §„Z 3141 .if tffi r FIRE (� ' 46 Deacon Street ►� I BLOCK{ PIT W ` ^.::. Sout h YarmouthMA , PAVED 50.18 PREPARED FOR: 4864 DRIVEWAY ::- x Jeremy &Jessica Giard X1, o 50.38 46 Deacon Street �^- BM South Yarmouth, MA 02664 49.31 .—X X �.x... . S NOTES: 49.85>c�- 119.7 g . -- O Deed Ref:: Bk 20150 & Pg 104 48.58 »w 30 580*2PROPOSED LEACHING TRENCHES 32.65'L x 3.00' W /.n' D MORAN ENGINEERING ASSOC, LLC CUL TEC RECHARGER 180HD 941 Main Street, Harwich, MA MiCHAE cnrcH -- ----- ------ .� PO Box 183, S. Harwich, MA 02661 S. BASIN , Yarmouth Health Department 508-432-2878 LADUE D Pr VED 3756 P� . AP: 079 PARCEL: 159 �No. o,E 0* � / ,0 / JOB NUMBER: 15-105 SCALE. fro 0 20' ame Date DATE: 5/10/15 SHEET: 1 of 2 SEPTIC TANK "D" BOX EL. 50.30 50.65 TOP OF COVERS TO BE WITHIN W OF GRADE FOUNDATION ACCESS PORT -,,,,,..EL 50.10 ACCESS PORTS s ANSH MIN FINISH GRADE 7- 47.30 El.. 47.1., 10'. t 1. Provide a clean out cap, to grade with cover, between the foundation and proposed septic tank. V 1. Extend inlet tee 10" min. below flow line; extend outlet tee 14" below flow line. 2. Provide 20" manholes over center of tank, inlet and outlet with readily removable impermeable covers. 3. Install access port over inlet and outlet with precast concrete or equivalent watertight riser within 6" min. of final grade. DEEP HOLE LOGS DATE: 6/10/15 DEEP OBSERVATION HOLE # 1 TEST BY: RICK JUDD TIME: 15:00 ELEV.From 50.30 COLOR SOIL Surface I HOR. TEXTURE (MUNSELL) MOTTLING S7RUCTURE CONSISTENCY, OTHER 49,63 8" HTM Fill NIA NO Lawn over mixed fill 49.13 14" AIEb Loamy Sand 1OYR 512 NO Granular 47.3036" Bwb Loamy Fine Sand 1 OYR 416 NO Very friable 38.80 138" C Fine to Medium Sand 10YR 614 NO Loose, single grain Bot. of Perc: 64" (24 Gallons of water poured. At 11:32 less than 6" remaining. RATE: < 2 MIN/INCH WITNESS: Amy von Hone, R.S., Yarmouth Health Department. "D" BOX NOTES I. -When system is dosed or slope of inlet pipe, excee0s.0.087ft. install inlet tee. cut-oftone inch above outlet invert. 2. Install outlet pipes level feet minimum. 3.: Provide a minimum sump ON.". outlet invert. -4. Install access port over "D" Box with precast concrete or equivalent watertight riser within 6" min. of final grade. ;DESIGN DESIGN DATA 1. REQUIRED FLOW: 3 - BEDROOMS X 110 - GPDIB.R = 330 - GPD 2. SEPTIC TANK CAPACITY: 330 - GPD X 2 = 660 -GPD USE (1)1500 - GALLON SEPTIC TANK (H-10) 3. LEACH FACILITY DESIGN: (2) 32.65'X 3.00'X 1 AT LEACHING TRENCHES (5 X 6.33) + 1.0'= 32.65 L.F. PER ROW 32.65 LF X 8.9 SFILF = 290.58 SF 290.58 SF X 2 - TRENCHES = 581.16 SF 581.16 SF X 0.74 GPD = 430.05 GPD CONSTRUCTION NOTES 430 - GPD PROVIDED > 330 - GPD REQUIRED 1. CONTACT OFFICE (508) 432-2878 A MINIMUM OF 2 - DAYS PRIOR TO START OF PROJECT. FAILURE TO NOTIFY OFFICE MAY CAUSE DELAY IN INSPECTION RESERVE AREA:100% PROCESS. 2. PUMP & FILL NORTHERN CESSPOOL. PUMP & REMOVE PRIMARY CESSPOOL. THE USE: (1)1500 -GALLON SEPTIC TANK (H-10) CONTRACTOR SHALL LOCATE PUMP AND FILL ANY ADDITIONAL CESSPOOLS LOCATED ON PROPERTY. (1) DISTRIBUTION BOX (DB -31H-10) 3. PLACE A TWO WAY CLEAN OUT BETWEEN THE FOUNDATION AND SEPTIC TANK. (2) ROWS OF 5 - CULTEC RECHARGER 180HD (SET AT 9.0' APART) PLACE A CONTROL BOX COVER OVER THE CLEAN OUT CAP. 2 - LEACHING TRENCH INSPECTION PORTS, WITH COVERS TO GRADE 4. A SOIL OVER -DIG INSPECTION OF THE PRIMARY CESSPOOL AREA IS REQUIRED 4" PVC VENT WITH "MUSHROOM" CHARCOAL FILTER. PRIOR TO PLACEMENT OF FILL. THE DESIGNER SHALL OBSERVE THE PROPOSED LEACHING AREA SOIL PROFILES PRIOR TO PLACEMENT OF LEACHING COMPONENTS. 5. ALL INSPECTION PORT AND ACCESS RISERS ARE REQUIRED TO BE INSTALLED. 6. CONTRACTOR SHALL PLACE VENT PER PLAN OR IN AN AREA TO BE LOCATED BY THE PROPERTY OWNER. VENT IS REQUIRED TO HAVE A CHARCOAL FILTER. 7. A FINAL INSPECTION IS REQUIRED PRIOR TO BACK -FILLING COMPONENTS. 8. LOAM, SEED AND REPAIR LAWN IRRIGATION AREAS IMPACTED BY CONSTRUCTION. ALL ADDITIONAL LANDSCAPE CONSIDERATIONS SHALL BE BETWEEN THE PROPERTY OWNER AND SEPTIC INSTALLER. k�tr� r (D Moran Engineering Associates, LLC LEACH FACILITY 5-CULTEC RECHARGER 18OHD -Control Box4'. or 6': PVC PULL_.CAP, .END CAP OR CLEAN-OUT. To GrSLOPE / ade /- 6' SCH. 40 PVC OR MIN 2% `SDR -35 PVC PIPE RISER MIN. 9' COVER INSPECTION PORTS - 2 MAx 36' COVERI t_ � FILTER FABRIC II. EL:47.10 t. 6.33' EACH UNIT (INSTALLED) 32.66' LENGTH INSTALLED I .6.60' T � CULTEC CROSS SECTION NATIVE SOIL—', NO WATER ENCOUNTERED ALTER FABRICr"c j.``,w .: f NOTES FOR CULTEC TITLES APPROVED FILL 1.) Must be a Cert.Cultec Installer. 2.) Cultec No. 410 Filter Fabric or equal approved by Cultec required. PIPE AT INVERT -PROPOSED VENT 14" 20.5" INVERT 100 ' u SIC 1.) ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE W=LE 5 OF THE SANITARY CODE & ANY APPLICABLE REGULATIONS. 2.) PRIOR TO BACK FILLING THE INSTALLATION, THE DESIGNER & HEALTH AGENT SHALL BE NOTIFIED FOR INSPECTION. 3.) ANY ALTERATIONS OF THIS DESIGN MUST BE APPROVED BY THE DESIGNER & BOARD OF HEALTH, IN WRITING. 4.) SYSTEM IS NOT DESIGNED FOR A GARBAGE GRINDER. 5.) THE INSTALLER IS TO VERIFY THE LOCATIONS) OF UTILITIES, CESSPOOL(S) AND SEWER INVERTS PRIOR TO CONSTRUCTION. 6.) ALL UNSUITABLE MATERIAL WITHIN 5 FT: IN ALL DIRECTIONS FROM THE SOIL ABSORPTION SYSTEM SHALL BE REMOVED & REPLACED W/CLEAN, COARSE SAND. 7.) ALL FILL MATERIAL UTILIZED FOR THE SOIL ABSORPTION SYSTEM SHALL BE CLEAN, COARSE SAND FREE FROM DELETERIOUS MATERIAL AND SHALL HAVE A PERCOLATION RATE OF LESS THAT 2 MIN./IN. BEFORE & AFTER PLACEMENT. 8.) EXISTING CESSPOOL(S) TO BE PUMPED AND BACK FILLED PER TITLE 5 ABANDONMENT PROCEDURES. 9.) DURING INSTALLATION, THE CONTRACTOR IS RESPONSIBLE TO PROVIDE A SAFE EXCAVATION AREA. 10.) GROUND COVER OVER SEPTIC SYSTEM COMPONENTS SHALL NOT EXCEED 36". 11.) ALL GRAVITY SEWER PIPE SHALL BE 4" DIA. SCH 40 PVC UNLESS OTHERWISE NOTED. THE MINIMUM SLOPE OF 4" DIA. SCH 40 PVC SHALL NOT BE LESS THEN 0.01 FT/FT. 12.) WHEREVER SEPTIC LINES CROSS WATER SERVICE LINES OR WHEN WATER SERVICE LINES COME WITHIN 10' OF THE PROPOSED S.A.S.- PIPES SHALL BE CLASS 150 PRESSURE PIPE & SHOULD BE PRESSURE TESTED TO ASSURE WATER TIGHTNESS. COORDINATE WITH LOCAL WATER DEPARTMENT. 13.) PLACE MAGNETIC MARKING TAPE OVER ALL COMPONENTS. 46 Deacon Street South Yarmouth, MA PREPARED FOR: Jeremy & Jessica Giard ASSESSOR'S SCALE: MAP: 079 jygt Scale PARCEL: 159 to DATE:, ....., :'d 6/10/15 SHEET •.2 4g 2 Moran Enginearihq Associates, LLC 941 Main St.,`Harwich, MA,. PQ -,Box 183, S. Harwich, MA 02661 508-432-287& -.