Loading...
HomeMy WebLinkAboutEngineered Plans - 2015I LEGEND —®—� PROPOSED CONTOUR r9-8-1 PROPOSED SPOT GRADE ---98 -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE EXISTING WATER SERVICE TEST PIT / BR BR \TH BR LIV ROOM DIN AREA FLOOR PLAN w t8. \00 00 19.3 0.24 ACRES ZC We � GPS? � 1 \ O �f o� KIT O� Q \ 0 a� C 20, 18.5 G.0 ABOVE GROUND POOL EXI5TING 1 ,50OG 5EPTIC TANK Yarmouth Health Department A PP PVED I)"� r7e10' AA -z-- SCALE: 1"=20' WE LOCUS MAP LOCUS INFORMATION TITLE REF: BK 12442 PG 072 PARCEL ID: MAP 049 PAR. 132 LOT SIZE: 0.24 ACRES SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 22 MEADOWBROOK ROAD WEST YARMOUTH, MA PREPARED FOR READY ROOTER EXC. SEPTEMBER 27, 2015 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmail.com www.meyerandsons.com SHEET 1 OF 2 J#1744 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS T.O.F. EL.=20.0± SEPTIC TANK PROPOSED D -BOX INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE /-F.G. EL.=18.8± /-F.G. EL.=18.5± /-F.G. EL: 18.0± 9" MIN COVER/ 36" MAX COVER L = 30' ® S=1% (MIN.) EL. 17.75 ® S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC .. t 0. f� '• INV.= 16.70 14w 48" UDUID INV.= 16.45 LEVEL GAS BAFFLE 1 INV.=15.70 EXISTING 1.500 GALLON SEPTIC TANK EXIST. SEWER OUTLET I NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) REPLACE EXISTING 1,500 GALLON SEPTIC TANK WITH 1500 GALLON SEPTIC TANK IF FAILED, DAMAGED, NOT H2O LOADING, OR UNDERSIZED. 4) INSTALL INLET & OUTLET TEES W/ PROPOSED D -BOX DB- (H2oi L = 10'(MAX) 0 S=1% (MIN.) 4"SCH40 PVC 11.3" TO INVERT INV.=15.0 - =15.50 BREAKOUT=TOP ELEV.=15.39 INV. ELEV.= 15.00 BOTTOM ELEV.= 14.06 TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:15.39 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL A 4" DIAMETER ;INSPECTION PORT OVER ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. /-F.G. EL: 17.7(MAX.) INSTALL TWO INSPECTION PORTS (MIN.) 4 ROWS OF 4 UNITS AT 6.25'/UNIT = 25'/ROW SOIL ABSORPTION SYSTEM (PROFILE) RESTORE VEGETATIVE COVER -BACKFILL WITH CLEAN PERC SAND TO TOP OF CHAMBERS EXISTING SUITABLE MATERIAL 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 4 x 2.83' = 11.32' (7.56' PROVIDED) USE 4 ROWS OF 4 -HIGH CAPACITY BOTTOM OF TESTHOLE: EL:6.50 = INFILTRATOR (H20) UNITS W/ ENDCAP-NO STONE GAS BAFFLE AS REQUIRED SEPTIC SYSTEM PROFILE DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOM DESIGN DESIGN FLOW: RESIDENTIAL: 3 BEDROOMS 0 110 GPD/BR = 330 GPD DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS I GARBAGE GRINDER: NO (not designed for garbage grinder) DISTRIBUTION BOX: USE DB -5 (1-120) N.T.S. (0.74 GPD/SF) SEPTIC TANK: 330 gpd x 200% = 660 gpd USE EXIST. 1,50OG SEPTIC TANK LEACHING AREA REQUIRED: (330)/.74 = 445.94 S.F. PRIMARY S.A.S. USE 4 ROWS OF 4 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473.0 SF DESIGN FLOW PROVIDED: TYPICAL SECTION N.Ta SOIL LOGS DATE: SEPTEMBER 24, 2015 SOIL EVALUATOR: DARREN M. MEYER, RS, CSE 1614 WITNESS: AMY VONHONE, YARMOUTH HEALTH TOTAL AREA = 473 SF 0.74GPD/SF(473SF) = 350 GPD > 330 GPD req'd Elev. TP- 1 Depth 17.50 0" FILL 17.00 6" A LOAMY SAND 16.50 1OYR 4/1 12" B LOAMY SAND 1OYR 6/6 15.00 30" MEDIUM SAND 2.5Y 6/6 46" PERC C2 MEDIUM 0 13.2 SAND 6.50 2.5Y 6/4 132" PERC RATE <2 MIN/IN. (*Cl* HORIZON) NO GROUNDWATER OBSERVED GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPUCA13LE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWELLING IS SERVICED BY MUNICIPAL WATER. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING LEACH PR TO BE PUMPED, CRUSHED AND FILLED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. 16. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING SECTION 11" INVERT HEIGHT END CAP INFILTRATOR - HI CAPACITY (H20) CHAMBER PROPOSED SEPTIC SYSTEM UPGRADE PLAN 22 MEADOWBROOK ROAD, PreDared for: Real System Design and Site Plan by: - MEYER & SONS, INC. * I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 PO BOX 981 to conduct soil evaluations and that the above analysis has been performed by me consistent with the EAST SANDWICH, MA 02537 requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam in October, 1999. 5082622922 WEST YARMOUTH, MA Rooter Exc. SCALE DRAWN DATE N.T.S. DMM 09/27/15 CHECKED SHEET NO. DMM 2 of 2