Loading...
HomeMy WebLinkAboutEngineered Plan - 2015PRECAST H-10 RISERS (IYP.) 2.0 FOUNDATION- EXIST PROFILE ALL SYSTEM SHALL BE TTAPE EXISTING CONTOUR X 99.1 I SYSTEM MARKED WITHCMAGNETIC OR PROPOSED CONTOUR 198.41 (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE MIN. 20" DIAIJ. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE CONCRETE COVERS TO WITHIN 3" GRADE SLOPE OF GROUND 2" PEASTONE OR GEOTEXTILE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING FILTER FABRIC OVER STONE MINIMUM .75' OF COVER OVER PRECAST f. 2% SLOPE REQUIRED OVER SYSTEM 46.0' NOTE: 2" MIN. WALL BLOCKS OR THICKNESS REQUIRED PRECAST RISERS 4 OSCH40 PVC MORTAR ALL H-10 46.6' 6` MIN. SUMP 12" MIN. INT. OIM. PIPES LEVEL 1ST 2' ENDS COMPONENTS (TMP) INV'S F1 42-5 SIDES 43.33' 10" **EXISTING 14" TANK TEE :' • .: Y.O°c'PO c°Y°°".°,P°°°°Je ' .._ '.,'.. ).. •''. :. ° °°°®®®� " ' w 0 �0 ��,®®� )O°OO '0°0°0°0°TEE >�o�o�00000,°p°o°o SEPTIC *45.2' WATERTEST D BOX 0°0°0°0 . ®0®�®000®a®17 ° ° ° ° 1- �o O° O °0 0 0 0°°>°°°°°°°° °��°���o�°° FOR LEVELNESS ®�®ate®a®®®oa0000aaa AFnmm o°0°0°00 GAS BAFFLE c� >00000000��0®®®®�®�01���®0�®P7 ° O O°00000°0 ;00000000° 40.5 42.82' 42.65' >°0°0°0°0 LH ACME PRECAST OR EQUAL. 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. -10 500 GAL. LEACHING CHAMBER BY (2) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [21) LEGEN D _99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[991-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2� SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS I (7.4 % SLOPE) (-!-% SLOPE) I SEPTIC TANK 32' D' BOX 12' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 8/27/15 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0°' 45.5' LS 4" 1OYR 3/2 B LS 220' 1OYR 4/6 43.7' C1 M/CS 34" 2.5Y 7/4 42.7' wj „ 6/2A2.5Y 6/2 41.5' 48 iiii C3 SIEVE M/CS 120" 2.5Y 7/4 35.5' NO GROUNDWATER ENCOUNTERED LICE #'5-2/7 ® UNSUITABLE SOIL 35.5' BOTTOM TH-1 NO GROUNDWATER FOUND LEACHING FACILITY **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE 'WITH 1500 GALLON H-10 SEPTIC TANK IF NOT SUITABLE (OR H-20 SEPTIC TANK IF IT WILL BE SUBJECT TO VEHICLE LOADING). LOT 62 A3 76. 36 11,625± S.F. R� 44 S99 2 , BENCH MARK - SILL AT �- 45 43 WALKOUT SLIDER. EL. = 47.0 �4 O / 0 Vj peOL_ Irx EXISTING DWELL. TOF = 54.2 / Z�7 00, 9�< 10 0O \ �O Scale:1 "= 20' 0 10 20 30 40 50 FEET aa� �44�� �TH1 U NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT .TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10ONTR CTOR SHALL BE RESPONSIBLE FOR P King's Way G ` Setucket ,p000 o Locus o � �o• 0 .dam °h Mill Pond a T 00 Stoney Hi/l Roa �o'o �ej1 .0 A CALLING DIGSAFE (1-888-344-7233) AND w VERIFYING THE LOCATION OF ALL UNDERGROUND & LOCUS H OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK.. NOT TO SCALE 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5'.BENEATH AND AROUND THE ASSESSORS MAP 135 PARCEL 23 PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) Yarmouth Health Department App V D = me Date DATE DANIEL A. OJALA, P.E., P.L.S. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD-" USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 **RE -USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #105 POMPANO ROAD YARMOUTHPORT, MA PREPARED FOR STEPHEN EATON DATE: AUGUST 28, 2015 off 508-362-4541 fax 508-362-9880 l downcope.com down cope engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 15-217 EATON.DWG