Loading...
HomeMy WebLinkAboutEngineered Plan - 201541.7' *34't* 33.49' PROVIDE IGHT ALL SY SHALL TE ACCESS COIVERS TO (WITH NAT6RTOF FIN. GRADE SYSTEM PROFILE MARKEDS WITHCMAGNETICTTAPE OR BE (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO ACCESS COVER AT FIN. GRADE 37.5' MINIMUM .75' OF COVER OVER PRECAST MINIMUM 1' OF COVER MINIMUM .75' OF COVER NOTE: 2" MIN. WALL OVER POLY TANK OVER PRECAST THICKNESS REQUIRED 4"s�SCH40 PVC 16.1 "(1.34') PIPES LEVEL 1ST 2' PROPOSED �. 33.24' GALLON POLYETHYLENE SEPTIC TANK 41 {. GAS 000000000000` 000 Iy �,�(. " BAFFLE ,4o°o�q�o Y •a :u. � r! Yx •. m -.+'.. aa'cc. u ,a .... w w*x; . x n � x 3. °j 33.10 X32.93' (2 % SLOPE) 6' COMPACTION. (15021M[2]H)ANICAL T IT! DEPTH OF FLOW = 4' WATER TEST FOR LEVELNESS REQUIRED TEE SIZES: INLET DEPTH = 10" MIN. BELOW FLOW LINE OUTLET DEPTH = 14" MIN. BELOW THE FLOW LINE (-!-% SLOPE) FOUNDATION- 10' SEPTIC TANK 14' - *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- - 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -V9 - PROPOSED CONTOUR 99 PROPOSED SPOT EL. TH1 1 a) REDUCTION IN SETBACK, SAS TO LOT LINE TEST HOLE 2� SLOPE OF GROUND FNDN (10' TO UTILITY POLE r FIRE HYDRANT NOTE. NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS WITHIN 3" OF FINISH GRADE 2% SLOPE REQUIRED OVER SYSTEM (-L-% SLOPE) - 3' - 16 H-20 HIGH CAPACITY UNITS (NO STONE PROPOSED) LEACHING FACILITY BENCH MARK - CORNER CONC. GARAGE APRON. ELEV. = 39.1' 4' G -W AT EL. 28.0' (NO ADJUSTMENT USED; CLAYEY SOILS) x 34.84 / 23.67' /.,�o 35.22 S E TH1� x 3 .1069 24" EE ®' / / H2 ^rn i / 2 6C m VO / / � A4 / 8 - __�_ I,8 __,' �- 3.0 . .7 1 11 GRAVEL 9�` _�g 0 PARKING AREA 39.4,839.52 � .49 GARAGE 4 1 ' x 39.49 SLAB EL. 40 39.3' 40.19 QC05 3 .32 O 41.1 / 0 40.41 � _ 1 ? 00 O /4 9 EXISTING DWELLING 4 .85 O O40.76 4 .94 EXISTING DWELLING TOP FNDN. = EL. 41.7' 41.. 3 �u 3 4 6 O � I 41- I \ 3 / 4 .54 1\ 14d, /D 6 / \ 3 / DECK 4 1'13\ \ I / 42.15 LOT AREA \3 1) 60.04 7,979 S� Ft. x 4 f x 2.07 \ 7 4 5x 42.38 A4L_2.zq � .45 AWAF � ___x 42.69 Scale:1 "= 20' STREET _ RO(/rE 6A 0 10 20 30 40 50 FEET NOTES 1. DATUM IS APPROX. NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE .PITCH TO BE 1/8" PER FOOT. 4: DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED x 36.19 o Tho e Rood 0 �. L cus C) � a c g 9` Sand i e o� Dennis Pond LOCUS MAP ENGINEER: DANIEL E. GONSALVES, SE #13587 ASSESSORS MAP 122 PARCEL 35 WITNESS: AMY VON HONE, RS COMPLIANCE 15.405: 1 a) REDUCTION IN SETBACK, SAS TO LOT LINE DATE: 1/7/15 (10' TO 8') 1b) REDUCTION IN SETBACK, ST TO FNDN (10' TO 5') r PERC. RATE _ < 2 MIN/INCH 15.415: LESS THAN 4' OF SUITABLE MATERIAL BENEATH SAS (1' VARIANCE) SYSTEM DESIGN: CLASS I SOILS ELEV. ELEV. 0" 35.5' 0" 36.0' A A LS LS 1OYR 3/2 1OYR 3/2 13" 18p, B B SL SL 24" 10YR 4/6 33.5' 26" 1OYR 4/6 33.8' G G SL SL 42" 1OYR 5/4 32.0' 66" 1OYR 5/4 30.5' C2 C2 SIEVE M/CS M/CS 90" 2.5Y 6/6 28.0' 90" 2.5Y 6/6 28.5' C3 C3 SL SL W/ SILT W/ SILT 132" 10YR 5/3 24.5, 132" 10YR 5/3 25.0' GROUNDWATER ENCOUNTERED GROUNDWATER ENCOUNTERED 90" EL. 28.0 ® 96" EL. 28.0 DCE # 14-373 WITHIN 3" OF FINISH GRADE 2% SLOPE REQUIRED OVER SYSTEM (-L-% SLOPE) - 3' - 16 H-20 HIGH CAPACITY UNITS (NO STONE PROPOSED) LEACHING FACILITY BENCH MARK - CORNER CONC. GARAGE APRON. ELEV. = 39.1' 4' G -W AT EL. 28.0' (NO ADJUSTMENT USED; CLAYEY SOILS) x 34.84 / 23.67' /.,�o 35.22 S E TH1� x 3 .1069 24" EE ®' / / H2 ^rn i / 2 6C m VO / / � A4 / 8 - __�_ I,8 __,' �- 3.0 . .7 1 11 GRAVEL 9�` _�g 0 PARKING AREA 39.4,839.52 � .49 GARAGE 4 1 ' x 39.49 SLAB EL. 40 39.3' 40.19 QC05 3 .32 O 41.1 / 0 40.41 � _ 1 ? 00 O /4 9 EXISTING DWELLING 4 .85 O O40.76 4 .94 EXISTING DWELLING TOP FNDN. = EL. 41.7' 41.. 3 �u 3 4 6 O � I 41- I \ 3 / 4 .54 1\ 14d, /D 6 / \ 3 / DECK 4 1'13\ \ I / 42.15 LOT AREA \3 1) 60.04 7,979 S� Ft. x 4 f x 2.07 \ 7 4 5x 42.38 A4L_2.zq � .45 AWAF � ___x 42.69 Scale:1 "= 20' STREET _ RO(/rE 6A 0 10 20 30 40 50 FEET NOTES 1. DATUM IS APPROX. NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE .PITCH TO BE 1/8" PER FOOT. 4: DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED x 36.19 o Tho e Rood 0 �. L cus C) � a c g 9` Sand i e o� Dennis Pond LOCUS MAP NOT TO SCALE ASSESSORS MAP 122 PARCEL 35 VARIANCES REQUESTED UNDER MAX. FEASIBLE COMPLIANCE 15.405: 1 a) REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 9') AND ST TO LOT LINE (10' TO 8') 1b) REDUCTION IN SETBACK, ST TO FNDN (10' TO 5') r 1h) REDUCTION IN G -W SEPARATION (5' TO 4') 15.415: LESS THAN 4' OF SUITABLE MATERIAL BENEATH SAS (1' VARIANCE) SYSTEM DESIGN: 1 GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW 5 REMOVAL OF UNSUITABLE SOIL REQUIRED SEPTIC TANK: 330 GPD (2) = 660 i x 36.14 AROUND PERIMETER OF LEACHING FACIOT-Y --USE A 1500 GAL. H-10 POLY SEPTIC TANK DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) LEACHING: POSSIBLE 36 OVERFLOW 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER TRENCH HIGH CAPACITY INFILTRATOR UNIT 330 GPD/0.74 GPD/SF = 445.9 SF LEACHING SEPTIC SYSTEM PER REQ'D ASSESSMENT SKETCH 36. 6 X 36.80 445.9 SF/29.56 SF/UNIT = 15.1 UNITS PROP. 1500 GAL FRALO OR THEREFORE, USE .GRAVELLESS SYSTEM OF (16) EQ. SEPTIC TANK P t I`d for REPAIR OF SEPTIC SYS'I'En9 1.- va r H-20 HIGH CAPACITY UNITS IN FIELD ONLY, due to State and Local septic variances. Board of Health review and approval is required for CONFIGURATION SHOWN any future additions/renovations/alterations to ���, sewage facilities and/or structures/6%elling. 16 UNITS X 29.5 SF = 472 SF > 445.9 SF ' ' ' Yarmouth Ilcalth t>� art'nent 472 SF (0.74) = 349 GPD (OK) APPR0N1-r D; -P' &A la .�e Date AFjf EXISTING DWELLING 1-7-1-115 DATE N OF 41,g8S�cy DANIELA o OJALA CIVIL No. 46502 o� A. r� v OJALA :n • ,o No. 40980 .,: , MA OVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 146 ROUTE 6A YARMOUTH PORT PREPARED FOR CATHY HAGOPIAN JANUARY 21, 2015 off 508-362-4541 I fax 508-362-9880 downcape.com 00011 Cd.Pe el) eeriag, 1*17c° civil engineers /and surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 0. N 0 �l Cn r J o� A. r� v OJALA :n • ,o No. 40980 .,: , MA OVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 146 ROUTE 6A YARMOUTH PORT PREPARED FOR CATHY HAGOPIAN JANUARY 21, 2015 off 508-362-4541 I fax 508-362-9880 downcape.com 00011 Cd.Pe el) eeriag, 1*17c° civil engineers /and surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675