Loading...
HomeMy WebLinkAboutEngineered Plan - 2015SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 55.0' MINIMUM .75' OF COVER OVER PRECAST 53.3'j 1 4"OSCH40 PVC PIPES LEVEL 1 ST 2 ,•; ` ; 10" EXISTING 14" TEE SEPTIC TANK** TEE 51.9±*'"` Roil: oUoouooGAS BAFFLE ::' oo'oo FOUNDATION EXIST. SEPTIC. TANK *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198•41 PROPOSED SPOT EL. TH1 �a tucket oa e TEST HOLE 2� SLOPE OF GROUND UTILITY POLE VY C FIRE HYDRANT -- - NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 5/28/15 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0" 53.8' A LS 4" 1OYR 4/2 B SL 1 1 " 1 OYR 5/4 52.9' C PERC CS 2.5Y 7/6 126" I 143.3' NO GROUNDWATER ENCOUNTERED LICE #15-111 ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE 2% SLOPE REQUIRED OVER SYSTEM 51.8' 1 51.63' 50.93' WATER -TEST D'BOX FOR LEVELNESS 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 24' X 11.3' COMPACTION. (15.221 [2]) (NO STONE PROPOSED) ( 1 % SLOPE) (1 % SLOPE) 7.2' 10' D' BOX 5' LEACHING FACILITY **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT BOTTOM TH 1 EL. 43.3' 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON H-10 SEPTIC TANK IF NOT SUITABLE (OR H-20 _ SEPTIC TANK IF IT WILL BE SUBJECT TO VEHICLE LOADING &/OR > 3' BELOW GRADE). permit valicD for REPAIR OT•1' SEPTIC SYSTEM ONLY, due to State and 104-31 septic variances. Board of health review and approval is reyuircd for any future additions/renovations/alterations to sewage facilities and/or structw es/dwelling. Yarmouth Ilealth ITel�artment / NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -M 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING .DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES. PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED. LOCUS MAP NOT TO SCALE ASSESSORS MAP 134 PARCEL 78 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): REDUCTION IN SETBACK SAS TO FOUNDATION (20' TO 16.5') SYSTEM DESIGN: 50.60 x51.67 GARBAGE DISPOSER IS NOT ALLOWED Date1 . . 17 j DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 110 GPD USE A 330 GPD DESIGN FLOW i 1.0 _ J j 4 54.37 LARGE EVERGREEN SEPTIC TANK: 330 GPD (2) = 660 L � 1_XTYP.� 1 \ ( ) RE -USE EXISTING SEPTIC TANK** �$ x�9.64� 1� / 3 ,� ' - �.. _.. - , _,^� ! ate.!; •.;;; _ _�, � .�r4-��` 1 :F rbr _ - .. - __. - ----. _- _--•---- - -- -. _- .. - -- --..._____._..-.- _.---- -- -- - --- ---- -- LEACHING• - �o.V, '0 4:72 SF LF x 4' LENGTH =' 18.88 SF .PER STD. P. 26 $ P ��� �;�, •. Vin, QUICK 4 UNIT 54,1 330 GPD/0.74 GPD/SF = 446 SF LEACHING / I 4 �� �0 -��'��-,�,�y� x ;Z..`� � 3 REQ'D .49.7 " 49.84 12 \ yPFs\ ., P \ =.f ti, 446 SF/18.88 SF/UNIT 23.6 UNITS 8.64 \: IVV , x 4474 54.36 x'S -1 " 54.61 THEREFORE, USE GRAVELLESS SYSTEM OF (24) \5 0 O 4 STANDARD QUICK4 UNITS IN FIELD CONFIGURATION / 52 PAVED DRIVE x'3.07 x/� 54.46 OF 4 ROWS OF 6 UNITS .S3 X3.09 p 5 0/ / 0A \ r •� 3. 2.68 53 3.a 553 3 3 93 0- 24 UNITS x 18.88 SF/UNIT = 453 SF> 446 SF b 4. 2 GJ54.47 453 SF (0.74 GPD/SF) = 335 GPD (OK) X2.41 �t4� - \ / 54.07 � .47 1 54.60 BENCHMARK 54.32vV BOTTOM OF STEP AT LANDING GARAGE ✓f EL. = 54.0' Scale: 1"= 20' 0 10 20 30 40 50 FEET S o� LOT 22 11,441± SF V �C @ ME 0FIR D JUN 1 7015 HEALTH I EXISTING DWELLING TOF = 55.0 DECK x 5-2� DATE 54.33 DANIEL A. OJALA, P.E., P.L.S. , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF. 771 ROUTE 6A YARMOUTHPORT, MA PREPARED FOR MARY VIOLET DATE: MAY 29, 2015 off 508-362-4541 fax 508-362-9880 I downcape.com 00Wn tape engineering, int. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 15-111 VIOLET.DWG King's Way a� 0J O �a �a tucket oa e c 0 Locu o� o en 0 to pe �h Mill Pond v� ooa LOCUS MAP NOT TO SCALE ASSESSORS MAP 134 PARCEL 78 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): REDUCTION IN SETBACK SAS TO FOUNDATION (20' TO 16.5') SYSTEM DESIGN: 50.60 x51.67 GARBAGE DISPOSER IS NOT ALLOWED Date1 . . 17 j DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 110 GPD USE A 330 GPD DESIGN FLOW i 1.0 _ J j 4 54.37 LARGE EVERGREEN SEPTIC TANK: 330 GPD (2) = 660 L � 1_XTYP.� 1 \ ( ) RE -USE EXISTING SEPTIC TANK** �$ x�9.64� 1� / 3 ,� ' - �.. _.. - , _,^� ! ate.!; •.;;; _ _�, � .�r4-��` 1 :F rbr _ - .. - __. - ----. _- _--•---- - -- -. _- .. - -- --..._____._..-.- _.---- -- -- - --- ---- -- LEACHING• - �o.V, '0 4:72 SF LF x 4' LENGTH =' 18.88 SF .PER STD. P. 26 $ P ��� �;�, •. Vin, QUICK 4 UNIT 54,1 330 GPD/0.74 GPD/SF = 446 SF LEACHING / I 4 �� �0 -��'��-,�,�y� x ;Z..`� � 3 REQ'D .49.7 " 49.84 12 \ yPFs\ ., P \ =.f ti, 446 SF/18.88 SF/UNIT 23.6 UNITS 8.64 \: IVV , x 4474 54.36 x'S -1 " 54.61 THEREFORE, USE GRAVELLESS SYSTEM OF (24) \5 0 O 4 STANDARD QUICK4 UNITS IN FIELD CONFIGURATION / 52 PAVED DRIVE x'3.07 x/� 54.46 OF 4 ROWS OF 6 UNITS .S3 X3.09 p 5 0/ / 0A \ r •� 3. 2.68 53 3.a 553 3 3 93 0- 24 UNITS x 18.88 SF/UNIT = 453 SF> 446 SF b 4. 2 GJ54.47 453 SF (0.74 GPD/SF) = 335 GPD (OK) X2.41 �t4� - \ / 54.07 � .47 1 54.60 BENCHMARK 54.32vV BOTTOM OF STEP AT LANDING GARAGE ✓f EL. = 54.0' Scale: 1"= 20' 0 10 20 30 40 50 FEET S o� LOT 22 11,441± SF V �C @ ME 0FIR D JUN 1 7015 HEALTH I EXISTING DWELLING TOF = 55.0 DECK x 5-2� DATE 54.33 DANIEL A. OJALA, P.E., P.L.S. , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF. 771 ROUTE 6A YARMOUTHPORT, MA PREPARED FOR MARY VIOLET DATE: MAY 29, 2015 off 508-362-4541 fax 508-362-9880 I downcape.com 00Wn tape engineering, int. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 15-111 VIOLET.DWG