Decision 4479 - Drawing A1 (Floor Plans)FIRST FLOOR PLAN FIRST FLOOR = 1296 S.F. SECOND FLOOR = 1263 S.F. TOTAL FINISHED SPACE = 2559 S.F. COVERED ENTRY = 40 S.F. COVERED PORCH = 370 S.F. TOTAL FOOTPRINT = 1709 S.F. SMOKE DETECTOR QC CARBON MONOXIDE DETECTOR WINDOW SCHEDULE TYPE MANUFACTURER'S UNIT ROUGH OPENING REMARKS A ANDERSEN ADH2850 2'-8" x 5'-0" DOUBLEHUNG B ADH3050 3'-0" x 5'-0" DOUBLEHUNG C ACW2634-2 5'-0" x 3'-4" AWNING (MULLED) D ACW2034-2 4'-0" x 3'-4" AWNING (MULLED) E ADH2848 2'-8" x 4'-8" DOUBLEHUNG F APW5448 5'-4" x 4'-8" PICTURE G ADH3048 3'-0" x 4'-8" DOUBLEHUNG H ADH3044 T-0" x 4'-4" DOUBLEHUNG 1. CONTRACTOR TO VERIFY ALL WINDOWS WITH OWNER AND ROUGH OPENINGS WITH WINDOW MANUFACTURER PRIOR TO ORDERING OF WINDOWS 2. ANDERSEN A -SERIES IMPACT GLAZING WINDOWS WHITE EXTERIOR W/ HIGH PROFILE EXTERIOR & INTERIOR GRILLES. LOW -E HP 4 GLAZING W/TRU-SCENE SCREENS & ESTATE SATIN NICKEL HARDWARE Ea F-< " COTUIT BAY DESIGN, LLC 43 BREWSTER ROAD MASHPEE ,MA. 02649 PH. (506) 274-1166 FAX (50 8) 539-9402 4S TES: ONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS DIMENSIONS IN THE FIELD ONTRACTOR TO VERIFY ALL INTERIOR & EXTERIOR MATERIALS, ETAILS, & FINISHES IN THE FIELD WITH OWNER DUGH OPENING HEAD HEIGHT OF WINDOWS AT t-IRST FLOOR TO BE 6'-8" ABOVE SUBFLOOR 4.) ALL CONSTRUCTION TO CONFORM TO 780 CMR MASSACHUSETTS STATE BUILDING CODE, 8TH EDITION AMENDEMENT & IRC2009 5.) THIS PROPERTY IS IN FLOOD ZONE V15 ELEV. 13.0 FEET 6.) 110 MPH EXPOSURE C WIND ZONE 7.) ALL SHEETS OF PLYWOOD WALL SHE�iTHING TO BE INSTALLED VERTICALLY, OR HORIZONTALLY W/ BLOCKING AT EDGES, 3"EDGE/12" FIELD NAILING 8.) ALL LVL LUMBER/BEAMS TO BE 1.9e L/480 LOAD 9.) SEE CERTIFIED PLOT PLAN DEVELOPED BY BSC GROUP FOR ALL PROPOSED & EXISTING DETAILS 10.) FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR INSTALLATION OF ALL SIMPSON COMPONENTS 11.) ALL CONCRETE USED FOR FOUNDATION WALLS, FOOTINGS & SLABS TO BE 3000 PSI 12.) VERIFY ALL PLUMBING & ELECTRICAL DETAILS W/ OWNERS ON THE SITE DURING FRAMING CONSTRUCTION 13.) THIS SITE IS IN THE 110 MPH WIND BOR''= DEBRIS AREA. EXPOSURE "C" & WITHIN ONE MILE OF NANTUCKET SCUND PER STATE OF MASSACHUSETTS WIND SPEED MAPS 14.) GLAZING PROTECTION PER 780 CMR 5301.2.1.2 TO BE IMPACT GLAZING & ROLL DOWN SHUTTERS, VERIFY ALL WIND BORNE DEBRIS PROTECTION REQUIREMENTS W/ OWNERS PRIOR TO START OF CONSTRUCTION 15.) TIMBER FRAMING TO BE SPRUCE/PINE/FIR NO. 2 GRADE 16.) PROVIDE UTILITY INSTALLATIONS FROM STREET TO NEW HOUSE VIA UNDERGROUND CONNECTIONS TO COMPLY W/ ALL LOCAL CODES 17.)ALL EXPOSED SIMPSON PRODUCTS & FASTENERS TO BE MADE OF STAINLESS STEEL 18.)ALL AZEK TRIM TO BE PAINTED WHITE &ALL JOINTS/NAIL HOLES SEALED. 19.)ALL WINDOWS &DOORS TO HAVE SILL PANS & ICEfWATER SHIELD FLASHING NEW HOUSE FOR:_ DUCOTE RESIDENCE 15 SHORE ROAD WEST YARMOUTH, MA SECONDO!R PLAN IECC2009 RESIDENTIAL ENERGY EFFICIENCY DETAILS CLIMATE ZONE 5A (USE EITHER PRESCRIPTIVE VALUES OR RESCHECK CALCULATION TABLE 402.1.1 (MINIMUM PRESCRIPTIVE INSULATION & FENESTRATION REQUIREMENTS) FENESTRATION U -FACTOR SKYLIGHT U -FACTOR CEILING R -VALUE WOOD FRAMED WALL R -VALUE FLOOR R -VALUE BASEMENT WALL R -VALUE EASEMENT SLAB R -VALUE CRAWL SPACE WALL R -VALUE 0.35 0.6038 20 30 10113 10 (2 FT. DEEP) 10/13 NOTES' 1. R -VALUES ARE MINIMUMS & U -FACTORS ARE MAXIMUMS. 2. 10/13 MEANS R=15 CONTINUOUS INSULATED SHEATHING ON THE INTERIOR OR EXTERIOR OF THE HOME OR R=13 CAVITY INSULATION AT THE INTERIOR OF THE BASEMENT WALL 3. REFER TO IECC 2009 CHAPTER 4 FOR ALL INSULATION & ENERGY REQUIREMENTS THE DESIGNER SHALL BE NOTIFIED IF ANY ERRORS OR OMISSIONS ARE FOUND ON THESE DRAWINGS PRIOR TO START OF CONSTRUCTION. THE BUILDING CONTRACTOR WILL BE RESPONSIBLE FOR THE CONTENT IN THESE DRAWINGS IF OR COMMENCES WITHOUT NOTIFYING THE DESIGNER OF ANY ERRORS OR OMISSIONS. THESE DRAWINGS ARE SOLELY FOR THE USE OF THE OWNER NOTED. ANY OTHER USE OF THESE DRAWINGS REQUIRES THE WRITTEN CONSENT OF THE DESIGNER. UNDER THE ARCHITECTURAL COPYRIGHT PROTECTION PRELIMINARY DRAWING FOR DESIGN REVIEW SCALE: 1/411 = 11-011 DATE . 9/16/2013 DRAWING NO.: