HomeMy WebLinkAboutDecision 4479 - Drawing A1 (Floor Plans)FIRST FLOOR PLAN
FIRST FLOOR
= 1296 S.F.
SECOND FLOOR
= 1263 S.F.
TOTAL FINISHED SPACE
= 2559 S.F.
COVERED ENTRY
= 40 S.F.
COVERED PORCH
= 370 S.F.
TOTAL FOOTPRINT
= 1709 S.F.
SMOKE DETECTOR
QC CARBON MONOXIDE DETECTOR
WINDOW SCHEDULE
TYPE
MANUFACTURER'S UNIT
ROUGH OPENING
REMARKS
A
ANDERSEN ADH2850
2'-8" x 5'-0"
DOUBLEHUNG
B
ADH3050
3'-0" x 5'-0"
DOUBLEHUNG
C
ACW2634-2
5'-0" x 3'-4"
AWNING (MULLED)
D
ACW2034-2
4'-0" x 3'-4"
AWNING (MULLED)
E
ADH2848
2'-8" x 4'-8"
DOUBLEHUNG
F
APW5448
5'-4" x 4'-8"
PICTURE
G
ADH3048
3'-0" x 4'-8"
DOUBLEHUNG
H
ADH3044
T-0" x 4'-4"
DOUBLEHUNG
1. CONTRACTOR TO VERIFY ALL WINDOWS WITH OWNER AND ROUGH OPENINGS
WITH WINDOW MANUFACTURER PRIOR TO ORDERING OF WINDOWS
2. ANDERSEN A -SERIES IMPACT GLAZING WINDOWS WHITE EXTERIOR W/ HIGH PROFILE EXTERIOR
& INTERIOR GRILLES. LOW -E HP 4 GLAZING W/TRU-SCENE SCREENS & ESTATE SATIN NICKEL HARDWARE
Ea F-< " COTUIT BAY DESIGN, LLC
43 BREWSTER ROAD
MASHPEE ,MA. 02649
PH. (506) 274-1166
FAX (50 8) 539-9402
4S
TES:
ONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS
DIMENSIONS IN THE FIELD
ONTRACTOR TO VERIFY ALL INTERIOR & EXTERIOR MATERIALS,
ETAILS, & FINISHES IN THE FIELD WITH OWNER
DUGH OPENING HEAD HEIGHT OF WINDOWS AT
t-IRST FLOOR TO BE 6'-8" ABOVE SUBFLOOR
4.) ALL CONSTRUCTION TO CONFORM TO 780 CMR MASSACHUSETTS
STATE BUILDING CODE, 8TH EDITION AMENDEMENT & IRC2009
5.) THIS PROPERTY IS IN FLOOD ZONE V15 ELEV. 13.0 FEET
6.) 110 MPH EXPOSURE C WIND ZONE
7.) ALL SHEETS OF PLYWOOD WALL SHE�iTHING TO BE INSTALLED VERTICALLY,
OR HORIZONTALLY W/ BLOCKING AT EDGES, 3"EDGE/12" FIELD NAILING
8.) ALL LVL LUMBER/BEAMS TO BE 1.9e L/480 LOAD
9.) SEE CERTIFIED PLOT PLAN DEVELOPED BY BSC GROUP FOR ALL
PROPOSED & EXISTING DETAILS
10.) FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR INSTALLATION OF ALL
SIMPSON COMPONENTS
11.) ALL CONCRETE USED FOR FOUNDATION WALLS, FOOTINGS & SLABS
TO BE 3000 PSI
12.) VERIFY ALL PLUMBING & ELECTRICAL DETAILS W/ OWNERS ON THE SITE
DURING FRAMING CONSTRUCTION
13.) THIS SITE IS IN THE 110 MPH WIND BOR''= DEBRIS AREA. EXPOSURE "C"
& WITHIN ONE MILE OF NANTUCKET SCUND PER STATE OF
MASSACHUSETTS WIND SPEED MAPS
14.) GLAZING PROTECTION PER 780 CMR 5301.2.1.2 TO BE IMPACT GLAZING &
ROLL DOWN SHUTTERS, VERIFY ALL WIND BORNE DEBRIS PROTECTION
REQUIREMENTS W/ OWNERS PRIOR TO START OF CONSTRUCTION
15.) TIMBER FRAMING TO BE SPRUCE/PINE/FIR NO. 2 GRADE
16.) PROVIDE UTILITY INSTALLATIONS FROM STREET TO NEW HOUSE
VIA UNDERGROUND CONNECTIONS TO COMPLY W/ ALL LOCAL CODES
17.)ALL EXPOSED SIMPSON PRODUCTS & FASTENERS TO BE MADE OF STAINLESS STEEL
18.)ALL AZEK TRIM TO BE PAINTED WHITE &ALL JOINTS/NAIL HOLES SEALED.
19.)ALL WINDOWS &DOORS TO HAVE SILL PANS & ICEfWATER SHIELD FLASHING
NEW HOUSE FOR:_
DUCOTE RESIDENCE
15 SHORE ROAD WEST YARMOUTH, MA
SECONDO!R PLAN
IECC2009 RESIDENTIAL ENERGY EFFICIENCY DETAILS
CLIMATE ZONE 5A (USE EITHER PRESCRIPTIVE VALUES OR RESCHECK CALCULATION
TABLE 402.1.1 (MINIMUM PRESCRIPTIVE INSULATION & FENESTRATION REQUIREMENTS)
FENESTRATION
U -FACTOR
SKYLIGHT
U -FACTOR
CEILING
R -VALUE
WOOD FRAMED WALL
R -VALUE
FLOOR
R -VALUE
BASEMENT WALL
R -VALUE
EASEMENT SLAB
R -VALUE
CRAWL SPACE WALL
R -VALUE
0.35
0.6038
20
30
10113
10 (2 FT. DEEP)
10/13
NOTES'
1. R -VALUES ARE MINIMUMS & U -FACTORS ARE MAXIMUMS.
2. 10/13 MEANS R=15 CONTINUOUS INSULATED SHEATHING ON THE INTERIOR OR EXTERIOR
OF THE HOME OR R=13 CAVITY INSULATION AT THE INTERIOR OF THE BASEMENT WALL
3. REFER TO IECC 2009 CHAPTER 4 FOR ALL INSULATION & ENERGY REQUIREMENTS
THE DESIGNER SHALL BE NOTIFIED IF ANY
ERRORS OR OMISSIONS ARE FOUND ON
THESE DRAWINGS PRIOR TO START OF
CONSTRUCTION. THE BUILDING CONTRACTOR
WILL BE RESPONSIBLE FOR THE CONTENT
IN THESE DRAWINGS IF OR
COMMENCES WITHOUT NOTIFYING THE
DESIGNER OF ANY ERRORS OR OMISSIONS.
THESE DRAWINGS ARE SOLELY FOR THE USE
OF THE OWNER NOTED. ANY OTHER USE OF
THESE DRAWINGS REQUIRES THE WRITTEN
CONSENT OF THE DESIGNER. UNDER THE
ARCHITECTURAL COPYRIGHT PROTECTION
PRELIMINARY DRAWING
FOR DESIGN REVIEW
SCALE:
1/411
= 11-011
DATE .
9/16/2013
DRAWING NO.: