Loading...
HomeMy WebLinkAboutEngineered Plan - 1998SEPTIC. PROFILE T.O.F. AT EL. 21.16' NOT TO SCALE) ACCESS COVER TO WITHIN 6" OF FIN. GRADE ( FE7 ACCESS COVER (WATERTIGHT) TO. 20.5' WITHIN 6" OF FIN. GRADE MINIMUM .75' OF COVER OVER P ECAST 2% SLOPE REQUIRED OVER SYSTEM RUN PIPE LEVEL 2" DOUBLE WASHED PEASTONEFE \ 19.0t m _ FOR FIRST 2' PROPOSED 1200 �S� Q \\\ 18.65' GALLON SEPTIC 18.4' o jjjT EETANK (H- 10 ) GAS w . 19.73' BAFFtE fn �" MIN 19.90 2 0 19.63' a ( % SLOPE) �6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) B 80 p 0.58' DEPTH OF FLOW 4 ( 1 % SLOPE) ( 1 % SLOPE) TEE SIZES: 1 T 3/4' TO 1 1/2" DOUBLE WASHED .ITONE INLET DEPTH = OUTLET DEPTH = 14 ALARM AND CONTROL PANEL ___-- LEACHING TO BE INSTALLED INSIDE FOUNDATION- 12''`'� SEPTIC TANK -.._6'_- PC - 20' - D' BOX 10' FACILIT! BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP WATERPROOFED SEPTIC TANK AND PUMP CHAMBER REQUIRED 21.0' 0.75 MIN 20.05' 3' ®SIDES 19.05' 4' OP 2" 6" 33" - 20.1 INV. IN 18.30' WEEP HOLE BENCHMARK \ 20.1 1000 GAL. H-10 S CATCH BASIN ` ELEV = 20.06' 20.5 `, USE ADJ. WATER ® 15.05' ALARM ON 800 GAL.+ 2" PRESSURE PIPE TO D'BOX RESERVE ASSUMED �� \ \ PUMP ON CHECK VALVE UTILITY 20.7 `\ Q POLE Q WELL: MIW 29 75" 0 4" WORKING RANGE 8' ZOELLER "WASTEMATE' \ ZONE; A J` 4" SUBMERSIBLE MODEL M282 1/2 HP PUMP \ \ v ADJ: (OCT.) 2.1' PUMP OFF 4" SYSTEM (OR EQUAL)\Lu 20\ PUMP CHAMBER 209 G ,-," 108 21.7 21.3 D 21.2 N 98-389 TEST HOLE LOGS ENGINEER: A.H. OJALA, PE WITNESS: AMY VON HONE, RS DATE: 11/10/98 PERC. RATE _ < 5 MIN/INCH CLASS I SOILS p# N/A 4 A SL 10YR 3/1 E LS 10YR 6/1 A55t55UK5 MAN 4L HANUtL U-' B B ZONING DISTRICT: YARD SETBACKS: . 10YR 5/6 FRONT = SIDE _ REAR = C PLAN REF. - MS FLOOD ZONE: C 2.5Y 6/6 obs. water (NOT TO SCALE) PAVED NOTE S i' DRIVE ELEV. 20.3' m 4 1738' 14.05' 11.30' - _ LOT 6 21. <21.2 � 20.2 20.3, \ Z-'21�o \ �G SEPTIC DESIGN: (GARBAGE DISPOSER Is NOT ALLOWED _ ) 1. DATUM IS APPROXIMATED FROM DENNIS QUAD o SO 3 �4I INIIr`1Dn-- '-tIATFR !S _EXISTING � , � RRnr � nsc 1 �; ".fin ,.• 20.6- \ G CAR � qac - USE A �.�GAS n GPD DESIGN FLOW 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. _ 10 . PORT SEPTIC TANK: 330 GPD ( 660 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H CONC. _? ) - \ � 5. PIPE JOINTS TO BE MADE WATERTIGHT. 20.7 METE SLAB � q USE A 1_50_0 GALLON SEPTIC TANK � 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. 20.7, 20.7 20' 20 s 1 .� LEACHING: _ ENVIRONMENTAL CODE TITLE V. 20.6 20.4^ N/A 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE EXISTING \ SIDES: I r � HOUSE 20.3 USED FOR LOT LINE STAKING. � " ?0.3 \, DECK TF = 21.16' 20• ` 30 x 15 (.74) _ 333 20. ^� �\ _ r J� 20.3 ; O 20. \ � BOTTOM: 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4!' PVC. ...TOTAL. 450 S. F. 333. GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT cEs�ggots � 1 21,2 20.7 20.3 \`\ USE LEACH FIELD OF 2 ROWS OF 4 STANDARD INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED 20.7 FROM BOARD OF HEALTH. 21 20.4,..\ 20.5 INFILTRATORS EACH, WITH 3' OF STONE AT SIDES AND 10. PUMP & REMOVE (OR FILL W/CLEAN SAND) :EXISTING CESSPOOLS. 20.3^ 20.6 20'6 3ETWEEN ROWS, 2.5' AT ENDS RAIL 11. ELECTRICAL PERMIT REQUIRED _ f LOT 5 FENCE 12. D'BOX TO BE WATER -TESTED FOR LEVELNESS QG Area = 19,360 sq.ftt 20.7 PER PLAN LEGEND 5' 20.5 12" PINES PROPOSED SPOT ELEVATION OF 2 3 Sl HTE AND SEWAGE PLANIDDEN ACRES AV E N U E 20.5 100x0 EXISTING SPOT ELEVATION 0 IN THE TOWN OF: VENT 19.5 "MAXIMUM FEASIBLE COMPLIANCE" � � 100 PROPOSED CONTOUR (WEST) YARMOUTH 15.405 1 I: SAS TO BE 4 ABOVE ADJUSTED GROUNDWATER 100 EXISTING CONTOUR 20 20.0 LOT 4MA 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF SYSTEM 19.4 DOWN TO MED. SAND LAYER. REPLACE WITH CLEAN MED. SAND. ENGINEER TO INSPECT AND CERTIFY REMOVAL. BOARD OF HEALTH APP OVED DATE I off 508-362-4547 fax 508 362-9880 I down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmou`;,'-i , ma 02675 PREPARED FOR: BORTOLOTTI CONSTRUCTION/BECKER 20 0 20 40 60 Feet SCALE: 1" = 20' DATE: NOVEMBER 20, 1998 �O ^ 4 V\1 s. DATE C : t a - Y _ ;7