Loading...
HomeMy WebLinkAboutEngineered Plan - 2010 - VOIDEDTOP OF FOUNDATION EL 16.74 4d" C. 0. 14.8 _ to grade Raise covers to within 6" of finish grade install risers as needed FG 12.5 21' to remain TOP11.49 20' Proposed 13.82 2"MIN-3"MAX INVERT EL 10.45 / N Existing 10" � INVERT EL I Bot EI 5.91 6" STONE BASE S = 0.08 41' Locus Locus Map N. TS. (1 71) FG 11.5 Proposed D - Box DB5 2.0' 14" 10.25 - INSTALL INV EL GAS 9.41 B" Slf AW BASE BAFFLE INV EL 9.24 L91 INV EL INV EL Proposed (H-10) 1,500 Gal Septic Tank Kit Bib Manda tory 5' Case Bdr Openings prior to BOH Septic Com pl ance � Certifica to LIv Bdr Lower Level Plan N. T.S. 0I 21' 2 ® 7' 2®4' ENCLOSED ENTRY ET Bth BASEMENT Bdr Bdr Ejector Pur and Soil Pipe Int Deck �1 First Floor Plan STANDARD NOTES Install Obs Port a t middle of its - r) THIS PLAN as FOR THE �e* /REPAIR OF A SEPTIC SYSTEM ,vast two outside un baht 40 PVC Screw it to rade 2) ALL LNSTALLA77oN PROCEDURES AND MATERIALS SHALL CONFORM TO 310 CMR 15.000, THE STATE ENVIRONMENTAL CODE, P g 77ME 5. AND THE TOWN OF YARMOUTH SUBSURFACE DISPOSAL RWULA770NS. 3) NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE OF AVAILABLE PROPERTY DVFVRMA77ON KITH RWORDED DEEDS FG 11.7 17 12 0 OR ZONING REGULATIONS. ' TOP = 4 ROWS OF SIX33 HIO INFILTRATER "QUICK 4 S" Qui 'ti p N 16 kd (12" x 48" .x 34" W/EFFECTIVE INVERT OF 8'9 11.33 x 24.00 DESIGN DATA Number of Bedrooms: 3 Garbage Grinder. NO Design Flow: 330 (VO Gal/BR/Day x Number o1 RM Color Septic Tank 1500g (Vinimum - Design Flow x 2007) (96 (Munsell) Gal. Leaching Area: OEA 24 UNITS x 40"/12"/ft x 4.72SF/LF IOYR4/3 t0YR5/1 -4*3 S.F. x 0.748/SF 9.7 4) 77HS PROPERTY IS SERVICED BY TOWN WATER 5) THERE ARE NO KNOWN WELLS WITHIN 100' OF THE PROPOSED SOIL ABSORPTION SYSTEM 2 5' 6) ALL COVERS OF SYSTEM COMPONENTS SHALL BE BROUGHT TO FTFA7N 6" OF FJMSHED GRADE 7) ALL SYSTEM COMPONENTS SHALL REMAIN ACCESSIBLE FVR INSPECTION. NO STRUCTURES SHALL BE LOCATED DIREL'7LY UPON OR ABOVE THE COMPONENT ACCESS LOCA770M WHICH WOULD INTERFERE WUH THE PERFORMANCE, ACCESS; INSPR PUMPING OR REPAIR 8" 12" 8) NO DRIVEWAY, PARKING OR TURNING ARt'A, OR OYH97? IMPERVIOUS AREA SHALL BE LOCATED ABOVE A SOIL ABSORP77ON EFFECTIVE SYSTEM EXCEPT WHEN VENTING HAS BEEN PROVIDED. SIDE WALL 9) SEPy7C TAAr)ir GREASE TRAPS. DOSING CHAMBERS AND DISTRIBUTION BOXES' SHALL BE PLACED ON A 6" STONE BASE TO ENSURE STABILITY AND PREVENT SE77IJNG. 10) OUM DIS7RIBU770N LINES SHALL REMAIN LEVEL FOR A MINW M OF THE FIRST TWO FEET OF THEIR LENGTH Il) ALL SYSTEM COMPONENTS SHALL BE CAPABLE OF WITHSTANDING H-10 LOADDVG UNLESS THEY ARE UNDER OR WITHIN 10' OF DRIVEWAYS OR PARKING OR TURNING AREAS, DY WHICH CASE H-ZO COMPONENTS SHALL BE USED. 12) ALL BUILDING SEWER LINES SHALL HAVE AN INNER DIAMETER OF 4" AND SHALL BE CAST-IRON OR SCHEDULE 40 PVC. 8.50 13) THE DEPTH OF THE 2VP OF ALL SYSTEM COMPONEN75 SHALL NOT EXCEED 36" UNLESS VENTING HAS BEEN PROVIDED. BOTTOM EL 14) DV THE AREAS OF EXCAVA770N, EXISTING GRADES SHALL BE REESTABLISHED UNLESS NOTED AS PROPOSED CONTOURS. 15) IF SONS ARE ENCOUNTERED DURING THE EXCAVA77ON OF THE SOIL ABSORP77ON SYSTEM, THAT DIFFER NOTABLY FROM THE DEEP OBSERVA770N HOLE LOG, CONTACT EAS SURVEY, INC AND TOWN BOH BF.FVRE PROCEEDING. Max Adj. Grd Water Elev 2.7 16) CONTRACTOR 7V VERIFY LOCATION OF ALL UNDERGROUND U=IBS PRIOR TO CONSTRUCTION 17) CHANGES OR REVISIONS yV SEP77C DESIGN REQUIRE NOTIFICATION 07 EAS SURVEY, INC AND TOWN BOX FOR REVIEW AND APPROVAL 18) CONMCTVR SHALL NOTIFY TOWN AND DESIGN ENGINEER AT LEAST 24 - 48 HOURS PRIOR TO INSPEC770N(S). 19) MAGNETIC TAPE 7V BE PLACED OVER ALL COMPONENTS ACCESS PODM- .20.) ELEVA77ONS FROM YARMOUTH ENGINEERING GIS MAP, ASSUMED U,SGS/NGVD DATUM BASE, BVTERSEC27ON OF CENTERLMWS) OF RUN POND ROAD AND AHJW ROAD. ELEV - 9.1 335 GPD Provided - 330 GPD Required = 5 GPD Reserve NOTE.- Abandon all three existing C.P. cesspools per Title 5, pump sand fill and crush -'.�------- a I14.4,) - o � $4 I (14.97) Gas Line 'II �ence`- I I I I. I I I ( (1 91) 1 I � X14 I 1 (131 1) 1 I --------�)----_----------_ o ____- 36.0' (15.0) Enclosed I I Proposed Basement I 1 SAS ti I I 4.57)- Entry 11 I 0 - -- - - ~ . LLQ nderground Electric Conc (1'1 11 T O t �� I Patio TBM EI = 14.45 I I c, I O L Cor Conc Pier 11'Proposed �0 8, 725- sq.(14.45 �b( - I Bldg ,#148 I I , 111, 500 Gal � 1 x 1 1 1 Mai 1 TCF B16 74 I I patio 1/ I I I I I Ent #148 I I 1((13.4) 1 i 1 S- Ta nk (y2.6) I tJ._L I I J-! L\ I Inv out = 13.82 I Deck To Remain I 21'4 I 1 41' Totrl Run 20' 1 00 I 1 I. (pa ved ) ( I Existing section t of Sch 40 1 V0, I Prop Clea'rJ I a� TYater Lime I I soil pipe tai I Out to gAJde ( (13.2) 1 1 ► remian I 1 w/screw ?dap C P. j 36.1 ' L I - - --(14. do) (15.5) ---`- J Con Patio 00 (14.95) " (Pa ved) - --- -- (Paved) 1 BGS 1 g) / Shed OV - -149.63', (13.19) p"4 Contractor responsible for pxivate Dig Safe of underground electric location NOTES: Parcel not within Zone H Contribution Owner of Record Lambrini Varetimos RPR Realty trust 4 Jannor Way West Yarmouth, MA 02673 Deed Reference D679975 Plan Reference L. C. 14114 A2 Lot 82 FEMA Map 250015-6D DEEP OBSERVATION HOLE'LOG Test Hole #1 (EL = 11.5 -E) D g tn�h ft) Horizon Texture Color (USDA) (Munsell) 0 - to" OEA FINE SAND IOYR4/3 t0YR5/1 10" - 22" 9.7 B LOAMY SAND 7.5YR6/6 22" - 72" 5.5 C1 MED SAND IOYR6/6 72" - 132" 0.5 C2 MED SAND 2.5Y7/4 Deep Obs Hole Date: 5-19-10 Soil Evaluator. ED STONE Witnessed By: AMI' VON HONE Pere Rate: < 2 MIN/IN 0 54" SOTTO Soil Survey Description: CARVER Geologic Material: GLACIAL 0177TASH MORRAINN Depth to Standing Water. 114" Mov - 2.0 Depth to Weeping Water. NA Depth to Mottling(Color): NA Est Seasonal High GW: ELEV 2.7 USGS Observation Well: MIW 29 INDEX G.7 Date of last_ Measurement: May 2010 Adj 0.7 - -- - �_�_a _ - Comments: 1JAOKtrtiE': icci�-,.:...i., -- -- - -H OF Mass DAVID D. -I .JR. ASSESSORS MAP 34 PARCEL 10 J21 Pere Test 11. Obs Hole 11' -Prop. D- BOX 1 � I I I� 1 I I I I I % �ZH OF cy EDWARD A. �+ STONE N Not. 28 8 a �YsV1=� .Q=k 10 SI t%S'ep t.zC Plan in Yarmouth, MA Located At 148 Run Pond Roa d y South Yarmouth, MA 02664 Prepared For --� RPR Realty Trust - 4 Jannor Iia Ties t Yarmo &-h, 111 026 � 1.9 : ' ne 9 010 SCALE - 1 \DATE �u PRE\PARED BY EAS S R VE'Y, INC. 3-andwch, ``--�Rte 6A PO Box 17 ` HA 02563Ph. X88843619 CELL 508-5 7-3600 AUG 3 0 2010 GRAPHIC SCALE HEALTH DEPT. 0 5 10 20 40 ( IN FEET ) 1 inch = 10 ft. Dwg It