Loading...
HomeMy WebLinkAboutDecision 3831 - Septic Upgrade PlanPARCEL H26 \ EXIST. ATCH �-C PARCEL 27 __ r / BASIN COT+CRE'E BOUND U 1 f 149.14 AT LE\' ,Sst PARCEL H28 PARCEL 1429 OEXIST. ------------- --- . O CATCH -T�-^�--,r-.__. O BASIN - --'--'--'� 1p , i --'-- - -- -- -- - --.-X144.47._.- --x-- -- 15.33 PAVED) .AREA .r--•-- _---- EXISTING LINE V (r x- SHED {fl �OF TRELS ' GAS i FENCE POGHT ST PARCEL W5 Area = 22072 N GATE 15.75 ' o , s ft f n s ! l% _ •--, I' 15.29 9• �.-._--G i. APPLE 0.51 Acres ,.. :. 1•-fi �. G 1 TREE. METER I f 15.21 EXIST WATER X11 11 _ SIRU1 1 ] GATE o•+' DOUBLE WATER. 5 -cjf d. Q LINES APPROX. EXISTIN 21'--�- f -' ! 1 I !� f ! f rte{ n 4 N LOCATION (SEE o „ NOTE D BEDROOM i_C 1 ASSESSORS MAP 36, PARCEL W3 Q. o G - �+ -'' ���NG� L --- 1 RESERVE AREA FLOOD ZONES B AND C, PANEL 250015 0006 D 1 11 a EXISTIN _._. o.F. AT c EL. 16.02 15 )B5 S.F• � 14.97 mA, 1aaOUING 10' '`'S 1 - (4) PROPOSED FLOW. gUIL FIR 1000 ?p, 4 - \\ o -I DIFFUSORS WITH 2' oTRAP GREASE �0-0 0 o�"A 00 00a �OF STONE ALL AROUND - SEPTIC DESIGN: (NO GARBAGE DISPOSAL ALLOWED). L // 19 00 0 ° o �. HOUSE: 2 BEDROOMS (110 GPD) = 220 GPD -TO.F- AT EL. ,s. 0 15.42 '00�Qo> ;o°� 09°.n9 - -_ STORE: 1600 S.F. (5 GAL./100 S.F.) = 80 GPD TAKE 11 1150 GPD .'3 i TOTALOUT DESIGNLIFLOW: 450 GPD 1� 12 FLOOR PROP, 1500�r EXISTING CESSPOOLS TO T,.1 FIRST 1718 GAL. SEPTIC _.--X-.__. _._-.-- ,�.....rx SEPTIC TANK: 450 GPD (1.5) = 675 GALLONS 1, A7 EL TANK x q X--� D 218 31 / USE A 1500 GALLON SEPTIC TANK m I LEACHING_ pARCEL W16 k c.'. SIDES: 2(36+8) (.96') (2.5) = 211.2 GPD PARCEL W2 BOTTOM: (36'*8') (1.0) = 288 GPD U , KEY TOTAL 372.5 S.F. 499.2 GPD USE (4) PRECAST 8x4' FLOW DIFFUSORS WITH 2' NOTE: PLUMBING IS TO BE RAISED AND HOUSE T.O.F. AT ELEV. 16.02 EXIST. CONTOUR --- I5 '- - OF STONE ALL AROUND KITCHEN AND BATHROOM FLOW EXIST FE�'CF ARE TO BE SEPARATED - ------ - - - EXIST. WA -ER -_1NE w -w- SEPTIC PROFILE- - -- ExlsnNc HOME EXIST. GAS LINE -c-----c----- y 2X SLOPE SEPTIC INVERT AT EXIST. ELEV. 32.50 TEST HOLE LOGS (NOT TO SCALE) - ELEV. 13.9{ PROP. KITCHEN STORE T.O.F. ELEV. 16.19 qlV'OF *CONTRACTOR TO VERIFY LOCA710N ENGINEER: JAMES C. JODICE FLOW INVERT BRING FRN'1Es /WD cWERS To FlNISH GRADE AND ELEVATION OF ALL EXISIING WITNESS: AMY VON HONE SEPTIC PIPES BRING COVERS TO Y71TH'N ELEV. 13.95 CHEAXY pvTYC^ST IRONS 1' OF FINISH GRADE DATE: MAY 18, 1994 PROP. BATH. ��/ f (EL. 15.5) MINIER OVER PRECAST 11 I/ f PERC. RATE _ < 2 MIN/INCH FLOW INVERT (EL. 15.0) ELEV. 13.91 -��- (1-110 LOADING) - .. (1110 LOADING) T �1 F-V XSLOPE IAY PIPE LEVEL V PERVIOUS GEOTEXTILE FABRIC 17. SLOPE - 1% SLOPE (HlO D85) OR FIRST 2' TO BE PACED OVER 2" OF 0' EL_14.97 WELL DATA. PROPOSED r 2' OF PEASTCN PEA5TOIJE TOP AND MIW 29 .1000 GALLON 13_ 31_ I //r SUBSOIL ZONE A m 13.57 GREASE TRAP �'' PROPOSED 1500 I � iR SLOPE II 1 EL 12.34 DATUM: 7.0' AcPPR X +. GALLON SEPTIC 12.98 -�'' o� o \ o o n 0 0 0` 1.5' EL 13.47 ADJ. = 0.87' LS 13.23 r .0 00000 - oao�o' FINE < ' TANK (HID) 12.13 LL��1'.9. -_ 00 o J�_<o�o �o-o n n r' o �ou�o"o EL 10.84 BROWN DEPTH OF FLOW = 4' \2' 32' 2' 3.5' SAND EL ,1.47 TEE SIZES: INLET DEPTH 10' 11.:0 3� 1 ORANGE OUTLET DEPTH = 34" DEPTH OF FLOW 4' \ - I 4• MED. TEE SIZES: INLET DEPTH - lCr \ I 4.5' SAND EL. 10.47 *CONTRACTOR TO VERIFY LOCATION 2% SLOPE OUTLET DEPTH = 19' �3/4' TO 1-1/Y Ii WHITE AND ELEVATION OF ALL EXISTING - WASHEL` 5�Ot1E A7.1u E4_WATER AT'L. 6.84 FINE SAND, SEPTIC PIPES _ WITH LEACHING SILT ADJUSTED WATER FOUNDATION 19' GREASE TRAP 9' SEPTIC TANK 85' D' BOX 16' - AT ELEV. 6.84 • FACILITY 9, OBSERVED WATERAT ---i 10' ELE. 5.97 .W- Q h NOTES: MED. EL 4 97 m_-3 off 508-362-4541 SAND fox 508 362-9680 1. DATUM ASSUMED FROM DENNIS QUAD MAP. 1r EL. 3.97o 2. MUNICIPAL WATER IS AVAILABLE L r O I PITCH TO BE 1 PER FT. 3. MINIMUM PPE ICH 8 4. DESIGN LOADING FOR PRECAST UNITS TO BE AAS -10-1110. n - ` down Cape engineering, inc. 5. PIPE JOINTS TO BE MADE WATERTIGHT. SEPTIC UPGRADE PLAN 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE V ITH MASS. 17N) CIVIL ENGINEERS ENVIRONMENTAL CODE TITLE V. FOR EXISTING BUILDINGS AT 46 SOUTH ST. IN THE TOWN OF: 7. THIS PLAN FOR PROPOSED WORK ONLY AND NOT TO BE USED rF.�T YARMOUTH, LAND SURVEYORS FOR LOT LINE STAKING. (SOUTH): 1 1 ARMO V 111, MA 8. SCHEDULE 40-4" PVC PIPE TO BE USED FOR SEPTIC SYSTEM. 93s main st. armouth, ma 9. D'BOX TO BE WATER TESTED FOR LEVELNESS. y 10. EXISTING WATER LINE TO BE SLEEVED IF IT IS LESS THAN 10' PREPARED FOR: FROM PROPOSED GREASE TRAP. T 3,� 11. CONTRACTOR TO VERIFY LOCATION OF ALL SITE JTILITIES PRIOR LORI NG S. M i E 1 1r71r� E TO ANY EXCAVATION. 20 0 20 40 60 Feet BOARD OF HRALTH ^II CIVIL YARMOUTH J7 t. o. Sae o 119Q MA SCALE: 1"=20' DATE: JUNE 6, 1994 y r�'/.•./ APPROVED DATE REV: TuLy I v-, '774- 'A v4 'd%i'N LA, J V DATE 94-166°`