HomeMy WebLinkAboutDecision 4079 - Floor PlansJ
W
z
rELUX -I NEW
SSLG Hr I SCREENED
ABOVE J PORCH
(VAULTED CEILING)
I I
I I
5'-4"
I VELUX
VS 304 1 1
SKYLIGHT
ABOVE J
EXIST.
HOUSE
3'0" x 68"
DOOR
n
NEW 4 x 4 P.T. POSTS W/
• 1 x 5/1 x 6 CASING
NEW
DECK
LEGEND:
EXISTING WALLS
CONSTRUCTION TO BE REMOVED
EM NEW CONSTRUCTION
,I
NEW 28" DIA. "BIGFOOT' FOOTINGS
UNDER 12" DIA. SONOTUBESAT
PORCH 4'0" DEEP
FOUNDA
EXIST.
OUTDOOR
SHOWER
NEW 12' DIA. CONC. SONOTUSES
TO 4'0" BELOW GRADE
ENDS
CCD
N
W
12
MATCH
ExlsT.
OF PLATE /
FIRST FLOOR
SUBFLOOR
3- P.T. 2x 12s —
b
v
CONT. RIDGE VENT
NEW ROOF CONST
- 2 x 10 ROOF RAFTERS @ 19'0.c.
112" CDX PLYWOOD ROOF SHEATHING
ASPHALT ROOF SHINGLES
-- --
2x 8's @ 16'0.c. -15LB. FELT PAPER
- MULTI LVL RIDGEBEAM
ov -- - SIMPSON H 2.5 HURRICANE CLIPS
AT ALL RAFTER ENDS
1 x 5 T & G - ICE! WATER SHIELD AT BOTTOM
BOARD 3'O" OF ROOF
CONT. ALUMINUM SOFFIT VENTS
MULTI LVL BEAM
to NEW 4 x 4 P.T. POSTS W/
0 1 x 5/1 x 6 CASING
NEW.
SCREENED
PORCH NEW WALL CONST.
1.2 x 4 STUDS @ 16' o.c.
2. 11T PLYWOOD SHEATHING
3. W.C. SHINGLE SIDING
NEW P.T. 2 x 10s @ 16 o.c. 4. TYVEK VAPOR BARRIER
BUILDING SECTION
P.T. 2 x 10 LEDGER BOARD LAG BOLTED TO
SOLID BLOCKING W/2) LEDGERLOK BOLTS
16" o.c. W1 JOISTS HANGERS AT BOTH ENDS
�— NEW 28" DIA. "BIGFOOT' FOOTINGS
UNDER 12' DIA. SONOTUSESAT
PORCH 4'0' DEEP
NEW PORCH
V'
VERIFY DECKING EXfST
W/ OWNERS HOUSE
NEW P.T. 2x12's 2x10's@16"o.c.
EXIS
CRA SPACE
NEW 12" DIA CONC. SONOTUBES b
TO 4'0" BELOW GRADE c
1�BUILDING SECTION (cD. NEW DECK
NOTES:
1.) CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS
& DIMENSIONS IN THE FIELD
2.) CONTRACTOR TO VERIFY ALL INTERIOR & EXTERIOR MATERIALS,
DETAILS, & FINISHES IN THE FIELD WITH OWNER
3.) ALL CONSTRUCTION TO CONFORM TO 780 CMR MASSACHUSETTS
STATE BUILDING CODE
ail
Q N
OC1 N O O
W�00
W cj� o
co 6.w
�O
F7+�1
O
C�
r SCALE:
1/4.. = 1,_0,
DATE:
10/11/2006
THE DESIGNER SHALL BE NOTIFIED IF ANY
ERRORS OR OMISSIONS ARE FOUND ON
THESE DRAWINGS PRIOR TO START OF
CONSTRUCTION. THE BUILDING CONTRACTOR
WILL BE RESPONSIBLE FOR THE CONTENT
DRAWING NO.:
IN THESE DRAWINGS IF CONSTRUCTION
COMMENCES WITHOUT NOTIFYINGTHE
DESIGNER OF ANY ERRORS OR OMISSIONS.
THESE DRAWINGS ARE SOLELY FOR THE USE
ON THE PROPERTY NOTED. ANY OTHER USE OF
THESE DRAWINGS REQUIRES THE WRITTEN
CONSENT OF THE DESIGNER. THESE DRAWINGS
ARE PROTECTED UNDER THE ARCHITECTURAL
COPYRIGHT PROTECTION ACT OF 1990.