Loading...
HomeMy WebLinkAboutDecision 4551�1'iGFF'L/�i I 'FAM\ u4 C J-Lbib41 i ata -'a CA��CE Doti 010 (01 'l `I '0 I _p ENTC2'fFY1NN1�'ni GQ U N PlnitsttEa N1 EGM'FYN IG!}LS SLinvaco.,n r F -'GD 1. 1'A-6L.lr E%L�ay Colv..�n O <'� O s Expn5e0 pLumL•'�1 =-F,t4,sl+FD 1?iJ o,` �rv1aMED S-1'aiLAG-G� BM 100.0 DOTING AT ALKOUT DOOR COVER WITH RISER COVER WITH RISER 6" BELOW. GRADE 6" BELOW GRADE NOTES 1. LEACHING PITS TO BE PUMPED OUT AND REMOVED, ALONG WITH ANY CONTAIMINATED SOIL. 2. INSTALL EFFLUENT TEE AND GAS BAFFLE ON EXISTING SEPTIC TANK 3. CERTIFIED PLOT PLAN REFERENCED DONE BY ELDREDGE SURVEYING COMPANY, 3/21/74. 14" TEE &/1 96.53 GAS BAFFLE TO BE INSTALLLED EXISTING 1000 GALLON SEPTIC TANK PIPE TO BE LEVEL FOR 2' OUT OF D -BOX 96.11 H-20 D -BOX 6" COMPACT STONE OR COMPACTED BASE 95.79 ,- INSPECTION PORT FINAL GRADE ® 99.16 1-�TOP @ 96.16 (21) QUICK 4 HIGH CAPACITY_ BOTTOM H-10 INFILTRATORS EL 94.83 3 TRENCHES (7 -INFILTRATORS + 6.53' 2 END CAPS) 3' X 28' WITH 6' BETWEEN TRENCHES - NO STONE 88.3 EL BOTTOM OF TEST HOLE #1 DESIGN CRITERIA NUMBER OF BEDROOMS: 4 BEDROOMS (/ &Y'l t SOIL TEXTURAL CLASS: CLASS 1 (.74) DESIGN PERCOLATION RATE: < 5 MIN/IN GARBAGE GRINDER: NO LEACHING AREA REQUIRED 440/.74 = 595 SF SEPTIC TANK: 440 GPD X 200% = 880 GALLONS USE : EXISTING 1000 GALLON PROPOSED D -BOX: 6DB H-20 USE (21) QUICK'4'HIGH CAPACITY INFILTRATORS (34" X 48" X 16") 3- 3' X 28' TRENCH CONFIGURATION, 6 END CAPS, NO STONE. BOTTOM AREA: (GENERAL USE APPROVAL FOR 7.93 SF/LF FOR TRENCH CONFIGURATION) 595 SF / 7.93 = 75; 75/4' = 18.75 UNITS USE: 21 UNITS 28X4' X7.93 X.74=492 GPD FLOOR PLANS (NTS) z z w z 2 Z s Y z z s J FAMILY BED BED I BED FIRST FLOOR 1. CONTRACTOR TO BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES, ABOVE & UNDERGROUND, PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 2. SEPTIC SYSTEM IS TO BE INSTALLED IN COMPLIANCE i1TH 310 CMR 15.00:TITLE V. 3. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE.. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM UPGRADE. 4. DESIGNER TO INSPECT & CERTIFY OVER - DIG, WHEN REQUIRED BY PLAN, AND FINAL INSPECTION BEFORE BACKFILL 5. CONTRACTOR TO PROVIDE 48 HOUR NOTICE FOR N:Y REQUIRED INSPECTIONS - 6 THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE DISPOSAL. 7. THE TOP OF ALL SYSTEM COMPONENTS SHALL BE HARKED WIN MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. B. IF SOILS ARE FOUND UNSUITABLE OR DIFFERING FROM THOSE FOUND IN SOIL LOG CONTACT DESIGNER AND THE BO',RD OF HEAL 9. IF UNSUITABLE MATERIAL IS FOUND IN THE PRIMARI OR THE RESERVE OF THE S.A.S. AN OVERDIG REQUIRING CLEAN GRANULAR SAND MEETING 310CMR 15.255(3) SHOULD RE USED AS FILL MATERIAL, 5' AROUND AND UNDER S.A.S. 10, ALL 4" PIPE CONNECTION AT SEPTIC TANK AND 0 -BOX SHALL BE MORTARED IN PLACE. IF USING 18' PLASTIC RISER PIPES, THESE TOO SHALL BE MORTARED IN PLACE. w F bar POOL ROOM SUN ROOM BASEMENT Health Whittier tea. I{aycee's WY o 0 s Ff Buck Island TEST HOLE LOG. DATE: 10-3-12 TEST BY: Michael O'Loughlin S.E. WITNESSED BY: Amy Von Hone PERC RATE < 5 MIN PER INCH TEST HOLE d# 1 0" 4 132 A LOAMY SAND 10YR 3/2 " BW LOAMY SAND 6" 10YR 5/6' 35" PER C M. F. S. " 2.5Y 7/6 99.3 EL 98.97 EL 97.97 EL 88.3 EL WATER NOT ENCOUNTERED TEST HOLE i# 2 O" QQ 3 FI A LOAMY SAND 10YR 3/2 BW LOAMY SAND 10YR 5/6 C M. F. S. 2.5Y 7/6 4" 20" 132" 98.97 EL NOT ENCOUNTERED 97.63 EL 88.3 EL a3' -n"