HomeMy WebLinkAboutDecision 3680 - Septic DesignTOP OF FOUNDATION 2t FT. MINIMUM FROM FOUNDATION ELEV.= 17.00 30 FT. MINIMUM It FT, MINIMUM FROM SLAB OR CRAWL SPACE (ASSUMED) 24" HDCI MANHOLE COVERS . 4" SCHEDULE 40 PVC /-MIN. PITCH 1/8" PER 4' CAST IRON PIPE (OR EQUAL) MINIMUM PITCH 1/4' PER FT, LELEV.= 14.00 r j 1'� LELEv.= 12-61 / rB E ELEV.= 12.86 J / -/ LEVEL BAFFLE ELEV.= 6 SUMP 12.07 ELEV.= 11.90 DISTRIBUTION LIOufD OUTLET <TO BE BOX PLACED ON FIRM BASE) DEPTH TEE TO BE WATER TESTED 1500 GALLON (TO BE PLACED ON FIRM BASE) 4 FEET 14 INCHES 5 FEET 19 INCHES SEPTIC TANK ELEV.=-/ 6 FEET 24 INCHES 11_70 7 FEET 29 INCHES (H-20) 8 FEET 34 INCHES 3(4" TO 1 1 2" CLEAN DOUB E WASHED STONE OF SEWAGE DISPOSAL SYSTEM PROFILE ANDESILTSINES (NOT TO SCALE) L -N- n 2' LAYER OF LOAM AND SEED 1/8' TO 1/2' CLEAN SAND l WASHED STONE 15.20 MAX. 12.20 72 =e e e e oma., �e o oe= o e Q oQ 02.1 PROPOSED SOIL ABSORPTION SYSTEM. 4 HIGH CAPACITY INFILTRATORS W/ 3.50' STONE ON THE SIDES AND 1.00' OF STONE ON THE ENDS. X 15.7 -i1� xV4.2 X V 41,4 4 HIGH CAPACITY INFILTRATORS WITH STONE IN AN 10' X 30' X 2' TRENCH FORMATION SOIL ABSORPTION SYSTEM (SAS) (H-20) LOT 18 AREA=4,697 S.F.f 368o- ZDD( ryfuln, np t' ryryi 3. 1s. n LEGEND X 706 EXISTING SPOT GRADE -66- - EXISTING CONTOUR -} 2f PROPOSED CONTOUR x =5 PROPOSED SPOT GRADE VENT OH -1 NOT REQUIRED Q� SOIL TEST LOCATION �•1 CU. FT. OF 7 F� ,/ CONCRETE ANCHOR ELEV.= 10.87 .,L__ N/A ?ONE z INDEX LO 9.47' USGS PROBABLE WATEF TABLE ELEV = _ OBSERVED WATER TABLE (11/4/00) ELEV = _ BCTTD" E TEST HDPE E'_E.. = 1.40 14.8 ,E0 0 EXISTING HOUSE AND SHED TO BE REMOVED Zg0'T PROPOSED 3 BEDROOM DWELLING r 15.2 W 4.413.8 OH -1 Y( 13.9 s / /l 14.6 C.O. tio_ 13.2 x 12.5 W\ 1.3.9 C.P. 4.0 >. x PROPOSED 1500 12'9 GAL SEPTIC TANK 'p / i i _/ �o V SITE PLAN S SCALE: I"=20' 11.6 lw_ WATER LINE + WATER SHUT OFF VALVE MOTT. EXISTING GAS UNE TO I it ryfuln, np t' ryryi 3. 1s. n LEGEND X 706 EXISTING SPOT GRADE -66- - EXISTING CONTOUR -} 2f PROPOSED CONTOUR x =5 PROPOSED SPOT GRADE VENT OH -1 NOT REQUIRED Q� SOIL TEST LOCATION �•1 CU. FT. OF 7 F� ,/ CONCRETE ANCHOR ELEV.= 10.87 .,L__ N/A ?ONE z INDEX LO 9.47' USGS PROBABLE WATEF TABLE ELEV = _ OBSERVED WATER TABLE (11/4/00) ELEV = _ BCTTD" E TEST HDPE E'_E.. = 1.40 14.8 ,E0 0 EXISTING HOUSE AND SHED TO BE REMOVED Zg0'T PROPOSED 3 BEDROOM DWELLING r 15.2 W 4.413.8 OH -1 Y( 13.9 s / /l 14.6 C.O. tio_ 13.2 x 12.5 W\ 1.3.9 C.P. 4.0 >. x PROPOSED 1500 12'9 GAL SEPTIC TANK 'p / i i _/ �o V SITE PLAN S SCALE: I"=20' 11.6 lw_ WATER LINE + WATER SHUT OFF VALVE MOTT. EXISTING GAS UNE 0"-11' CLEAN OUT C.P. O CESSPOOL ( i CATCH BASIN 11'-20" B 12 VARIANCES TO TITLE 5: A. SAS LESS THAN 10' FROM PROPERTY UNE B. SAS LESS THAN 20' FR3M FOUNDATION C. SEPTIC TANK LESS THAN 10' FROM PROPERTY UNE D. NO RESERVE AREA I A. \ DjM%�p NO 6A • NO SOIL TEST DATE OF SOIL TEST: 11-28-00 SOIL TEST DONE BY: SWEEISElt ENONEERIN° WITNESSED BY: A VON HONE OBSERVATION HOLE: 1 ELEV.= 14.4 PERCOLATION RATE <2 MIN./INCH ® 62" DEPTH ORIZ TEXTURE COLOR MOTT. OTHER 0"-11' A/P LOAMY SAND 10YR 4/1 330 GAL./DAY 11'-20" B LOAMY SAND IOYR 5/6 1500 GAL, 20'-35' Cl MEDIUM FINE 2.5YR 6/8 < 2 MIN./IN. 35"-38' C2 COARSE SAND 7.5YR 6/8 460,00 40% 38"-156' C3 MEDIUM FINE 2.5YR 6/8 340.40 GRAVEL ENCOUNTERED AT 156" ELEV.= 1.4 DESIGN CALCULATIONS: NUMBER OF BEDROOMS, 3 PROPOSED SEPTIC DESIGN GARBAGE DISPOSAL UNIT NO FOR TOTAL ESTIMATED FLOW RT 2,9 PHIL C URRAN (110 GAL./BR./DAY X 3 BR.) 330 GAL./DAY REQUIRED SEPTIC TANK CAPACITY: __6 54_ GAL. ACTUAL SIZE OF SEPTIC TANK: 1500 GAL, SOIL CLASSIFICATION: I 26 WINDEMERE ROAD DESIGN PERCOLATION RATE: < 2 MIN./IN. EFFLUENT LOADING RATE: 0.74 GAL./DAY/S.F. LEACHING AREA: 460,00 50. F.T. (10 X 30) + (40 X 2 X 2) 1 WEBSTER RD. LEACHING CAPACITY (AREA X RATE): 340.40 GAL./DAY 460.00 X 0.74 ST RESERVE LEACHING CAPACITY: NONE GAL./DAY NOTES: 1. ALL WOP:KMA4SH:P AND MATERIALS SHALL CONFORM TO O.E.P. TITLE 5 AND T.HE TOWN OF YARMOUTH RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2 ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6' OF FN;SnED GRADE, 3 ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARK,NG AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF ` rLS PARK ,,., A EAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTIUTIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL 'DGSAFE' AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE 7. CONTRACTOR TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE 8ROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8. PARCEL IS W FLOOD ZONE Al2, B (Al2-ELEV. 10) . 9. LOT IS SHOWN ON ASSESSORS MAP 21 AS PARCEL 35 . 10. EXISTING SEPTIC/CESSPOOL(S) TO BE PUMPED AND REMOVED. 11. RE-ROUTE EXISTING WATERLINE AS SHOWN. APPROVED BOARD OF HEALTH DATE AGENT WEST YARMOUTH, MA PROPOSED SEPTIC DESIGN FOR RT 2,9 PHIL C URRAN `MILL PR=cr L =0N: LOT 18 3E, CARVER RD. 26 WINDEMERE ROAD CREEK WEST YARMOUTH, MA 02673 ALDENRD. 1 WEBSTER RD. SWEETSER ENGINEERING 235 GREAT WESTERN ROAD ST PO BOX 713 SOUTH DENNIS, MA 02660 /) 2 off. 508-398-3922 to. 508-396-5063 W1fVDEMERE DATE, 12-19-00 SCALE 1"=20' o1 -os -o1 � JOB NO. 500-00 LOCUS MAP NOT TO SCALE 01-29-01 '1", SHEET 1 OF 1 T,C•T 2000 SWEETSER ENOINEERIND