HomeMy WebLinkAbout50 Powers Lane Site and Sewage PlanGENERAL NOTES:
A.) NEITHER DRIVEWAYS NOR PARKING AREAS ARE ALLOWED OVER SEPTIC. SYSTEM -
UNLESS H-20 COMPONENTS ARE USED.
B.) THE DE51GNEP WILL NOT 13E RESPONSIBLEFOP THE SYSTEM AS DESIGNED UN-
LE55 CONSTRUCTED AS SHOWN. ANY CHANGES SHALL BE APPROVED IN WRITING.
C.) CONTRACTOR SHALL BE RE5PON5(BLE FOR VERIFYING THE LOCATION Of ALL
UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO COMMENCEMENTOF WORK.
CONSTRUCTION NOTES:
I.) ALL CONSTRUCTION SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE,
TITLE 5, AND THE. REQUIREMENTS OF THE LOCAL BOARD Of HEALTH.
2.) 5EPTICTANK(5), GREA5ETRAP(5), DOSING CHAMBER(5) AND DISTRIBUTION
BOX(E5) 511ALL BESET ON A LEVEL STABLE BASE WHICH HAS BEEN MECHANICALLY
COMPACTED, OR ON A 6 INCH CRUSHED STONE BASE.
3.) SEPTIC TANK(5) SHALL MEET A5TM STANDARD C 1 127-93 AND SHALL HAVE
ATLEASTTHREE 20° DIAMETER MANHOLES. THE MINIMUM DEPTH FROM THE BOT-
TOM OF THE SEPTIC TANK TO THE FLOW LINE SHALL BE 48".
4.) SCHEDULE 40 PVC INLET AND OUTLET TEES SHALL EXTEND A MINIMUM OF G'
ABOVE THE FLOW LINE OF THE SEPTIC TANK AND SHALL BE INSTALLED ON THE
CENTERLINE OF THE TANK DIRECTLY UNDER THE CLEANOUT MANHOLE.
5.) RAISE COVERS OF THE SEPTIC TANK AND DISTRIBUTION BOX WITH PRECAST
INLET AND OUTLET TEES TO WITHIN. G' OF
LOT 17A
ZONING
TABLE
6.) PIPING SHALL CONSIST OF 4' SCHEDULE 40 FVC OR EQUIVALENT. PIPE SMALL
ZONE: (RESIDENTIAL)
0-2'
F-25
7.64'
Water Level Adjustment:
REQUIRED
EXISTING
PROP05ED
MIN. LOT SIZE
25,0005.F.
8;676
8,676
MIN. FRONTAGE
150 FEET
1.88.93'
188.93'
FRONT YARD SETBACK
30 FEET
40.91-
47.1'±
SIDE YARD SETBACK
L5 FEET
10.9'+
30.41*
REARYARD SETBACKS
20 FEET
29.8'*
22.2'±
MAX. SHAPE FACTOR (LOT)
22
16
16
BUILDING COVERAGE
25%
9.5%v
13.7%
EXISTING BUILDING COVERAGE:
PROPOSED BUILDING COVERAGE:
HOU5E AREA
HOUSE AREA (INCLUDING ADDITION)
LAYER Of [/8r TO 1/2" DOUBLE WASHED STONE FREE OF IRON, FINE5 AND DUST.
X too
-_-_- LIMIT OF WORK
X 100
LOT AREA
11-) VENT SOILA1550RPTION SYSTEM WHEN DISTRIBUTION LINES EXCEED 50. FEET;
WHEN: LOCATED EITHER IN WHOLE OR IN PART UNDER DRIVEWAYS. PARKING AREA5,
LOT AREA
629 S.F- X 100 = 9.5%
1 ,190 5.F.
X 100 = 13.7%
8;676 5.f.
8,676 5-F.
CLEAN MEDIUM SAND (EXCLUDING TOP501LL
CONCP.ETEWATERTIGHT RI51-P.SOVER
FINISH GRADE, ORAS APPROVED BYTHE LOCAL 130ARD OF HEALTH AGENT.
- Depth to Water Table (C/5115); 6.4' (EL= -O. 13)
Appropriate fndcw Well:
6.) PIPING SHALL CONSIST OF 4' SCHEDULE 40 FVC OR EQUIVALENT. PIPE SMALL
.CONSERVATION NOTES:
0-2'
BE LAID ON A MINIMUM CONTINUOUS GRADE OF NOT LESS THAN !%..
7.64'
Water Level Adjustment:
7.) DISTRIBUTION LINES FOR 501L ABSORPTION SYSTEM (A5 REQUIRED) SHALL BE
1.) LIMIT Of WORK SHALL BE AS SHOWN: A STAKED, 9- FOUND STRAW WATTLE SHALL
5.1 (EL= I. 1 7)
4" DIAMETER SCHEDULE 40 PVC LAID AT 0:005 FTIFT, UNE SHALL BE CAPPED
BE CONSTRUCTED ALONG THE LIMIT OF WORK UNE PRIOR TO THE COMMENCEMENT OF
AT END OR AS NOTED.
Of ANY WORK.
5.6
8.) OUTLET PIPES FROM DISTRIBUTION BOX SHALL REMAIN LEVEL FOR AT LEAST
-,- GAS SERVICE LINE
2' BEFORE PITCHING TO 50€L ABSORPTION SYSTEM. WATER TEST DISTRIBUTION
2.) ROOF RUN-OFF FROM DWELLING SHALL BE CONTROLLED BY GUTTERS, DOWNSPOUTS
5T SEPTIC TANK
BOX TO A55URE EVEN DISTRIBUTION..
AND D"RELL5 OR STONE TRENCHES UNDER DRIP LINE5.
9.) DISTRIBUTION BOX 511ALL HAVE A MINIMUM SUMP OF 6" MEASURED BELOW
Restive RESERVED FOR FUTURE
THE OUTLET INVERT.
rol UTILITY POLE
10.) BASE AGGREGATE FORTHE LEACHING FACILITY SHALL CON515T OF 3/4" TO
,10, FIRE HYDRANT
I-1/2" DOUBLE WASHED STONE FREE OF IRON, FINE5 AND DUST AND SHALL BE
0 WELL
INSTALLED BELOW THE CROWN Of THE D15TPJPMION LINE TO THE BOTTOM OF. THE
SOIL AB50RPTION SYSTEM, BASE AGGREGATE SHALL BE COVERED WITH A 2'
'
100' Buffer
TOP OF BANK
LAYER Of [/8r TO 1/2" DOUBLE WASHED STONE FREE OF IRON, FINE5 AND DUST.
-_-_- LIMIT OF WORK
Zone: Dune
FENCE
11-) VENT SOILA1550RPTION SYSTEM WHEN DISTRIBUTION LINES EXCEED 50. FEET;
WHEN: LOCATED EITHER IN WHOLE OR IN PART UNDER DRIVEWAYS. PARKING AREA5,
PROP05ED 1500 GALLON SEPTIC TANK
TURNING AREAS OF OTHER IMPERVIOUS MATERIAL; OR WHEN PRE55URE-D05ED.
AND H2O DISTRIBUTION BOX (DB3)
12-) SOIL ABSORPTION SYSTEM SHALL BE COVERED WITH A MINIMUM OF 9' OF
v )
CLEAN MEDIUM SAND (EXCLUDING TOP501LL
13.) FINISH GRADE SHALL BE A MAXIMUM OF 36' OVER THE TOP Of ALL SYSTEM
DOSING CHAMBER
COMPONENTS, INCLUDING THE SEPTIC TANK, DISTRIBUTION BOX,
A MINIMUM. COVER
100 YEAR FLOOD PLAIN
Q z
AND SOIL ABSORPTION SYSTEM. SEPTIC TANK5 SHALL HAVE
`
QF 9".
ZONE AE ELEVATION I 1 .O
} "a
0
14.) FROM THE. DATE OF INSTALLATION Of THE SOIL AB50R=TION SYSTEM UNTIL
MAP hI2500 1 5-u5f.3'5j
RECEIPT OF A CERTIFICATE OF COMPUANCE, THE PERIMETER OF THE SOIL ADSORP-
EFFECTIVE JULY 1 G, 20 14
'
Y, -29O
TION SYSTEM SHALL BE STAKED AND FLAGGED TO PREVENT THE USE OF SUCH
SEE NOTE 18
!
Ttt
AREA fop ALLACTIVTTIE5 THAT MIGHT DAMAGE THE SYSTEM.
15-) THE BOARD OF HEALTH SHALL REQUIRE INSPECTION OF ALL CONSTRUCTION
THIS SYSTEM RE-
� --
➢C
BY AN AGENT OF THE BOARD OF HEALTH (ORTHE DESIGNER IF
SUCH PERSON TO CERTIFY IN WRITING
50' EwtFer
une
tiJ
QUIRES A VARIANCE) AND MAY REQUIRE
THAT ALL WORK ELAS BEEN COMPLETED IN ACCORDANCE WITH THE TERMS OF THE.
-
IFVK AIT AKm APP n%/Fn PI ANS. 4A HOURS ADVANCE NOTICE 15 REQUESTED.
} /�
I G.) EXISTING 1000 GALLON SEPTIC TANK AND -D15TIBI-TION-BOX TO BE PUMPED
1 AND REMOVED FROM SITE, INCLUDING ANYCONTAMINATED SOIL.
17-) PLUMBING TO BE RA15ED AND p --LOCATED AS PER PLAN VIEW AND PROFILE.
RELOCATE 4.2 FEET NORTH. OF HOUSE CORNER AND RP.15(f TO 3 FLET BELOW TOP
OF FOUNDATION. ALL PLUMBING CHANGES TO BE COMPLETED PER MA STATE
PLUMBING CODE AND COMPLETED BY:A MA STATE PLUMBER. INSTALLER TO VERIFY
SAS INVERT PRIOR TO PLUMBING CHANGE OR SETTING SEPTIC TANK.
18.) FLOOD PLAIN NOTE5:
PLAN COMPLETED USING THE 1988 NAVD DATUM AND THE CURRENT FLOOD MAPS
EFFECTIVE JULY 16, 2014. EXISTING DWELLING CONSTRUCTED 1987. PROPOSED
ADDITION Wlll BE LE55 THAN. 50% OF THE VALUE OF THE EXISTING 5TRUCTUP.E_
REFER.TO OLD FLOOD MAPS, SEE FEMA PANEL 925001 5-OO5DREV15ED JULY 2,
1 992,ZONE A.12, FLOOD ELEVATION 10.0. USING 1929 DATUM: -EXISTING
DWELLING Tor EL=10.0, FINISH FLOOR EL= I I. D AND AVERAGE. FINISH GRADE
EL- 8.1.
FLOW PROFILE:
NOT TO SCALE 24" DIAMETERCONCRETE COVERS
RAISED To WfTHfN 6' OF FINISH
TOP OF FOUNDATION GRADE (ORAS NOTED)
EL-- 9.1 # (SEE NOTE #5)
D . `tM1r a
Proposed EL 7-25
si
41 un
bin
110" I. 14"
3 l
4'O' T
I GAS BAFFLE -
1 500 GALLON
SEPTIC TA�k
"SEE NOTE 17 - PLUMBING TO BE
THREE (3) COVERS TOTAL
booting Flow Dlffv5or5 with Stone/
TO REMAIN
PROPOSED LIMIT OF WORK
Beach Acce55 S at Ir t Walk aw y_
Coa5tal- Dune
INSPECTION NOTE:
PRIOR TO FINAL INSPECTION BYTHE ENGINEER, SYSTEM
-NEEDS TO BE COMPLETE INCLUDING BUILDUP FOR COVERS.
-P.....,..�oA F1 - G I
c ,,:iv
5:04 4.87
3.67`
YARMOUTI
SYSTEM DESIGN CALCULATIONS: MA
SEWAGE DE51GN FLOW: TO RT. 28
3 BEDROOM DWELUNG @ I 10 GPD = 330 GPD
:LEACHING CAPACITY REQUIRED:.
3 BEDROOMS (MAX.) @ I 10 GPD = 330 GPD REQUIRED -
SEPTIC TANK CAPACITY REQUIRED: -
DAILYFLOW = 330 GPD @ 200% = 660 GAL. REQUIRED
SEPTIC TANK CAPACITY PROVIDED:
1500 GALLONS PNC TANK (MILD. ALLOWED)
LEACHING CAPACITY EXISTING: �O LOCU-5
373 GPD>330 GPD REQUIRED ?4
s POWEP.5 LN
NOTE: A GARBAGE D15POSAL 15 NOT PERMITTED WITH T11I5 DESIGN. ��
INSTALL Cam .--.-.-.-.--.-.-'-.-'
ONE (1) - 1500 GALLON SEPTIC TANK.ONE (1) -3 OUTLET DISTRIBUTION BOX (H-20 Rated) V
THREE (3) -RISERS AND CONCRETECOVERSWITH 9 FINISH GRADE Q)
n NOT TO SCALE
Ew5ting 1000 Gallon Septic Tank l n
And DBox TO BE REMOVED
t3
PROPOSED ADDITION TOF EL= 9.1
TOS IN CRAWL SPACE EL 5.3 MINMLIM
CB
FND
X 6.0
�'-
x
LOT 17A PLAN
Area=8,676 5P-
ro s+ w x 65 x 72 SCALE 1"=20'
.Edge of Geznng o
62
Exrstirny 3.Bedroom
7X25 Dwelling,
l�
_6.�- a.'a �� 1.6 FF 99'-' r x 7. n1
6
4 Q ,I w!
"- ! TNG SEE NOT -17 ..
9 7.3
('LUMB i;sf��
p 72
630 4`F `O.
7 /5
f�. , 17. J i •!`l � xIS.3
>:6 7.0 - T
1
7.0 % � X7 x ix, y x e.3
® 6 -Driveway II - x 6. x 6.8 !�q 72
O x 7.0 n
x T7 88 A ik
fl 6A .2
WG l 69 x
�-�4
Ed of Pavement
SANE
TOWEtZS
30' PR4VATE WAY!
BENCHMARK:
Top of.PK Nail Set
EL=6.4a- WAVE) 1958)
1
Goy'ta/
HIGH GROUNDWATER. LEVEL CALCULATION
- Depth to Water Table (C/5115); 6.4' (EL= -O. 13)
Appropriate fndcw Well:
NIIW29
WaterLevel Rance Zone:
0-2'
Current Depth to Water Level (5115):
7.64'
Water Level Adjustment:
1.3'
Estimated Depth to Water Level:
5.1 (EL= I. 1 7)
2.5 0 20 40 GO
Longest P.un
ly-EL= 1.17 NIGH GROUNDWATER SCALE I"=20'
P -BOX _ 1.3'
- .-4- - EL= -0.13 OD5ERVED GROUNDWATER06105/15SEE SEPTIC INSPECTION ON FILE @ f30H
H-20
IFn AS PEP. Pt AN VIEW. PROFILE AND NOTE 17.
50 PCVrrR5 IAN EIDVVG17070 5DS PLAN.DF"dG
OCT 2 0 2015
Ab,-tt -'1t
HEALTH DEPT.
REVISED PLAN, 10/14/15: ADJUSTED MINIMUM CRAWL SPACE SLAB ELEVATION
TO EL= 53, ABOVE EXISTING SAS F3EVATfON.
REVISED'PLAN, 10[7115: CORRECTED CONSERVATION NOTES, CHANGED NOTE 17
AND CHANGED SEPTIC ROW PROFILE ELEVATIONS..
Tseng Residence
do Jim Hagerty, Reef, Care Cods Home Builder, PO Boz 186, West Dennis, MA 02670
51TE * SEWAGE D15P05AL 5Y5TEM PLAN
50 POWERS LANE, YARMOUTH, MA
J.M. OTEILLY & ASSOCIATES, INC.
Professional Engineering & Land Surveying Services
1575 Main Street - Route SA
P.O. Bos 1779
(508)896-6601 Office Brewster, Mil 02691 (508)696-6602 Fax
DATE: 5CALE: BY:: CHEGK: JOB NUMBER
0911 711 5 A5 Noted MTF,rgb JMO JMO-7070
L.C. PLAN# 1 G770C
CERTIFICATE# 177212
A55E55OR5' MAP 15 PARCEL 14
LEGEND
--. -32 EXISTING CONTOUR
32 PROPOSED CONTOUR
x12.34 EXISTING SPOT GRADE
24x5 PROPOSED SPOT GRADE
-W- WATER SERVICE LINE
-r- UG ELECTRIC UTILITY SERVICE
-T- UG TELEPHONE UTILITY SERVICE
-,- GAS SERVICE LINE
0 TEST HOLE I BORING LOCATION
5T SEPTIC TANK
DB .DISTRIBUTION BOX
SAS SOIL ABSORPTION SYSTEM
Restive RESERVED FOR FUTURE
rol UTILITY POLE
ID CATCH BASIN
,10, FIRE HYDRANT
0 WELL
0 DRAINAGE MANHOLE
■ CONCRETE BOUND, FOUND
TOP OF BANK
-_-_- LIMIT OF WORK
FENCE
EDGE OF CLEARING
OCT 2 0 2015
Ab,-tt -'1t
HEALTH DEPT.
REVISED PLAN, 10/14/15: ADJUSTED MINIMUM CRAWL SPACE SLAB ELEVATION
TO EL= 53, ABOVE EXISTING SAS F3EVATfON.
REVISED'PLAN, 10[7115: CORRECTED CONSERVATION NOTES, CHANGED NOTE 17
AND CHANGED SEPTIC ROW PROFILE ELEVATIONS..
Tseng Residence
do Jim Hagerty, Reef, Care Cods Home Builder, PO Boz 186, West Dennis, MA 02670
51TE * SEWAGE D15P05AL 5Y5TEM PLAN
50 POWERS LANE, YARMOUTH, MA
J.M. OTEILLY & ASSOCIATES, INC.
Professional Engineering & Land Surveying Services
1575 Main Street - Route SA
P.O. Bos 1779
(508)896-6601 Office Brewster, Mil 02691 (508)696-6602 Fax
DATE: 5CALE: BY:: CHEGK: JOB NUMBER
0911 711 5 A5 Noted MTF,rgb JMO JMO-7070