Loading...
HomeMy WebLinkAboutEngineered Plans - 2015N N 0 N N SCALE: 1"=20' 0K BEAVER IM = EL. 50.0 )LKHEAD FOUND. Yarmouth Health Department APP VED -s Name Date BED BATH LEGEND PROPOSED CONTOUR F9 8-1 PROPOSED SPOT GRADE --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE TEST PIT SCALE: I"=20' Yarmouth Health Department APP VED -s Name Date BED BATH KIT ROOM FAM ROOM LIV BED ROOM ROOM WEST YARMOUTH LOCUS: 8 BEAVER BROOK RD. LOCUS MAP LOCUS INFORMATION TITLE REF: C360250 PARCEL ID: MAP 58 PAR. 360 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 8 BEAVER BROOK RD. WEST YARMOUTH, MA PREPARED FOR EVELYN NEVARAS OCTOBER 26, 2015 10 OF �SsgCyG C o ARREN MEM \. 0. 0 cisi S01TW b 2,6� 1 MEYER & SONS INC. P.O. BOX 981 E. SANDWICH, MA 02537 PH. (508)360-3311 FAX: (774)413-9468 meyerandsonsinc@gmail.com SHEET 1 OF 2 J#1660 T.O.F. NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS TP -1 Depth 49.70 SCALE NOTE: PLACE RISERS OVER ALL COVERS W/IN 6" OF GRADE MEYER &SONS, INC. A FINISHED GRADE (49.50) EL: 50.0 F.G.EL: 49.2 F.G.EL: 49.40 F.G. EL: 49.50 tOYR, 3/1 DATE 2% MIN SLOPE OVER LEACHING AREA aMAINTAIN 508,362-2922 4" 10/26/15 B LOAMY :4 TOP TANK=EL. 47.85 SAND 2" OF 3/8" DOUBLE WASHED 3/4" - 1-1/2" ~ * .. ., 47.20 STONE OR FILTER FABRIC DOUBLE WASHED S1 30" 6" C 4" SCH 40 PVC a 10"I PERC ® EL. 45.86 aa®• O ®®®® ¢: TEE'S ARE TO BE 14 ::: 6 INV.46.83 @ S= 1% (MIN.) ®®®®®®®®®® 2' EFF. DEPTH ®®®®®®®®E3® jitE :Q :....A... 4" SCH 40 PVC 38.70 132" INV.46.65 42 X 8.5' 4' GAS PROPOSED DB -3 EXISTING OUTLET E BAFFLE (H20) DISTRIBUTION BOX EFFECTIVE LENGTH = 25' EL. 47.50 o1c=- INV. 47.18 PROP. 1,500 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) SEPTIC TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES AS REQUIRED GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING CESSPOOL TO BE PUMPED, CRUSHED, REMOVED AND FILLED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO ABUTTING PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4" SCH 40 ® 1/8"/FT (UNLESS SPECIFIED) of Mgss9�yG DARK N M. o E � 'PEGlS1��0 SAN I TAYO SEPTIC SYSTEM PROFILE SOIL LOGS INV. ELEV.= 46.40 TOP CONC. ELEV.= 47.40 INV. ELEV.= 46.40 _ BOTTOM EL.= 44.40 SEPARATION 5.60 FT. UST. GRNDWATER EL: 38.70 DATE: OCTOBER 1, 2015 SOIL EVALUATOR: DARREN MEYER, CSE 1614 WITNESS: AMY VONHONE, YARMOUTH HEALTH Elev. Nevaras TP -1 Depth 49.70 SCALE DRAWN 0" MEYER &SONS, INC. A LOAMY' SAND DMM PO BOX 981 EAST SANDWICH, MA 02537 tOYR, 3/1 DATE 49.37 SHEET I 508,362-2922 4" 10/26/15 B LOAMY SAND 1OYR 5/8 47.20 30" C BOTTOM FINE - PERC ® EL. 45.86 MEDIUM SAND 2.5Y 7/4 38.70 132" PERC RATE <2 MIN/IN. ("C HORIZON) NO GROUNDWATER OBSERVED • I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that l have passed the Soil Evol. Exam in October, 1999. BREAKOU' ELEV.= 47.4 ®® E3 ®®® ®®®®® E3lria®I®® 3.75' SIE 5 FT. �_ 3.75' EFFECTIVE WIDTH = 12.5' SOIL ABSORPTION SYSTEM (SECTIONi (500 GALLON LEACH CHAMBER) DESIGN CRITERIA NUMBER OF BEDROOMS: 2 BEDROOM EXIST/3 BEDROOM DESIGN (NOT IN ZONE II SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 3 BR = DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 330 gpd x 200% = 660 gpd, USE NEW 1,500 GAL. SEPTIC TANK LEACHING AREA REQUIRED: (330) = 445.94 S.F. .74 USE TWO (2) 500 GALLON PRECAST LEACH CHAMBERS W/ 4' STONE ON ENDS & 3.75' STONE ON SIDES: 25' L x 12.5' W x 2'[ BOTTOM AREA: 25' x 12.5'= 312.50 SF SIDE AREA: (25 + 12.5) X 2 X 2 = 150 SF TOTAL SQUARE FEET PROVIDED = 462.50 vs. 445.94 REQ'D DESIGN FLOW PROVIDED: 0.74(462.50 S.F.) = 342.25 G.P.D. vs. 330 G.P.D. req', I PROPOSED SEPTIC SYSTEM UPGRADE PLAN Prepared for: Nevaras System Design and Topography Plan by: SCALE DRAWN MEYER &SONS, INC. N.T.S. DMM PO BOX 981 EAST SANDWICH, MA 02537 DATE CHECKED SHEET I 508,362-2922 10/26/15 DMM 2 of