HomeMy WebLinkAboutEngineered Plan - 2015POND LOCUS IO o: H O 'N 4 KEY: EXISTING CONTOUR: — — — — PROPOSED CONTOUR: ............. EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25.5 TEST HOLE: + UTILITY POLE: —O— FENCE LINE: - HYDRANT: RETAINING WALL: LOCATION MAP LOT 14 (17,414 SF) ASSESSORS MAP: 39 PARCEL: 105 LAiV O CCUI R t CASE 28197 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY �I SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK ^LEACHING AREA: f USE 2 - 500 GALLON CHAMBERS (8.5'x 4.8'x 2' EFF. DEPTH) WITH t 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) SIDE AREA: (25' + 12.8') x 2 x 2 = 151 SF (0.74) =_112 GAL/DAX BOTTOM AREA: 25'x 12.8'= 320 SF (0.74) = 237 GAL/DAl(I CAPACITY = 349 GAL/DAY N I/� ��(/• 25.00' O Fz' Fry9e afp '9 i 4� / `S 60° elf i 3 2` /\ 777��0 99 O � Scw , ao, oo 100 r ---- — W i \ ------------__ CK AGE i \ FENCE ------ GARDET \ i J EXISTING PORCH 3 BEDROOM / i DWELLING / !/ top fnd.= 101.74 / i \1 invert = 98.0 DECK 12"OAKS 36"OAK th-1 \\ i �cp 12" � OAKS ST i /)/60740 \ \ \ 012" 12 , i !ti k ?de OAK oSSeg R i i M 15-54 I 19 9 1st SEPTIC SYSTEM SECTION 101.74 TOP OF ° FOUNDATION 98.0 ELEV. 97.4 ELEV. 1500 GAL SEPTIC TANK ((6" OF STONE UNDER OR MECHANICALLY COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN COVERS OF FINIS Yarmouth Hedth Department A ___ A Airr"w V ELF Date BENCHMARK AT RIGHT CORNER OF BULKHEAD ELEVATION = 100.07 2nd FLOOR DECK LIVING DINING ROOM PORCH ROOM MUD I ROOM KITCHEN BATH R DECK EXISTING FLOOR PLAN BED ROOM bh MAX. COVER (V MIN) 96.95 ELEV. ELEV. D -BOX (6" STONE UNDER) / ELEV. -GAS BAFFLE AT OUTLET TEE TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS: AMY VON HONE, R.S. DATE: 10-8-15 PERCOLATION RATE: < 2 MIN/IN NOTES: 2" PEASTONE OR FILTER FABRIC — 3/4" - 1 1/2" WASHED STONE INSPECTION PORT �— ELEV.= 97.33 IMI 9 ° ° ° ° ° I'I! 94.5 4 <-> ELEV. 25'x 12.8' 2 - 500 GALLON CHAMBERS 07-19H 4' OF STONE ALL AROUND (25'x 12.8'x 2' DEEP) TH-1 100.0 O/A HORIZONI ELEV. LOAMY SAND 10YR 4/1 99.3 B HORIZON LOAMY SAND 10YR 5/8 1 97.7 C HORIZON MEDIUM SAND 2.5Y 7/4 138" NO GROUND WATER ENCOUNTERED 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8 ALLCO(TNSTRUCTION DETAILS TLE FIVE) AND LOCAL RE TOO E IN CO FORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3'. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING CESS POOLS ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED. 14. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. (Jvart . v 'll !/ THOMAS J SITE PLAN LOCATION: 21 SULLIVAN RD., W. YARMOUTH, MA PREPARED FOR: MIKE & DIANE SHEA DATE: 10-9-15 SCALE: 1" = 20' BASS RIVER ENGINEERING P E P.O. BOX 1163, EAST DENNIS, MA 02641 508-385-3426 OR 508-364-9048