Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 20150 i UTILITY POLE TEST HOLE EL=19.1' UTILITY POLE LAMP POST— , -I PAVED',,DRIVE'kkil Ilk) 2 LJ E ` CTRICAL I FROM EXISTIN � ' GAR H SE (LOBATE) I r ; I I x AGE I ; 1 I I 1 EXISTING CESSb�00LS;;�i I X !PUMP AND FIL� (note 10) W r I I I I I I I I W I , WATER GATE SOUTH YARMOUTH PROP. 2,500 GALLON 2—COMPARTMENT SEPTIC TANK (1,50OG/1,000G) ® / TOP OF COASTAL BANK AT EL. 9.0 P-0I11i�■■r►�.: ,2, 9 t , t 1 , 1 1 1 t t 0 (BENCHMARK CORNER BRICK STEP EL=18.5' �; � w LOCUS 28 CHARLES ST. SCALE: 1"=30' + 96.52 LOCUS INFORMATION W— EXISTING WATER SERVICE kE TEST PIT � z R TITLE REF: BK 11681 PG 294�HOFMass 9` PARCEL ID: MAP 070 PAR. 114 0�� JOHN LOT SIZE: 1.10 ACRES v� DEMAREST,JR. COO FLOOD ZONE: "AE" EL. 11.0 q No. 36859 m� COMM. PANEL: 25001CO591J q°� ss Q ROUrf 2g DATED: 07/16/14 SURve It it LOCUS MAP I STONE WALL EXISTING CESSPOOLS TO BE PUMPED AND HAND FILLED ?3? 0?' LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE & TEST PIT EDGE OF SALTMARSH FLAG ELEV=2.5' EDGE OF SALTMARSH FLAG ELEV=3.0 EDGE OF SALTMARSH _AG EL=2.6' Yarmouth Health Department ---_.r APP OVED ,17 /;� PROPERTY SUBJECT TO RIVERS ACT. ame .� Date MEAN HIGH WATER NOT LOCATED. -c"T �**� WETLAND DELINEATION CONDUCTED BY: BRAD HALL SEPTIC SYSTEM OF qs REPAIR PLAN LOCATED AT: o D E► �, 28 CHARLES STREET 1 1 SOUTH YARMOUTH, MA o PREPARED FOR �NITAR�1'� JEN N EY 1 O.1 OCTOBER 16, 2015 REVISION — NOVEMBER 10, 2015 MEYER & SONS INC. P.O. Box 981 E. SANDWICH, MA 02537 PH: (508) 360-3311 FAX: (774) 413-9468 meyerandsonstitle5@gmail.com www.meyerandsons.com SHEET 1 OF 2 747 M NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS SEPTIC TANK T.O.F. EL.=18.701 INSTALL RISERS & COVERS OVER INLET & PROPOSED D -BOX OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & COVER INSTALL LOCKING COVERS IF AT FINISH GRADE SET TO 6" OF GRADE l-F.G. EL.=17.50± /-F.G. EL.=18.50± F.G. EL: 19.0± 0 S=1% (MIN.) 4"SCH40 PVC INV.=15.82 9" MIN COVER/ 36" MAX COVER EL.=16.85± -f6' I 10" 14` 1,o0OGAL. OMP. COMP. GAS BAFFLE GAS BAFFLE L = 10' 0 S=1% (MIN.) 4"SCH40 PVC INV.=15.57 INV.=15.47 PROP. 2 -COMP 2.500 GALLON SEPTIC TANK R OUTLET EL. 16.06 EL. 16.62 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) -3) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED 4) PLUMBING TO BE RE-ROUTED TO OUTLET 6 SHOWN. BOTTOM OF OUTLET PIPE TO BE 32" BELOW TOP OF FND. INJECTOR PUMP TO BE INSTALLED TO PUMP UP BASEMENT FLOW, 2 OF 5 BEDROOMS, (PLMBG PERMIT REQ'D) NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:16.10 FOR A DISTANCE 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL RISER W/ METAL RINGS AND COVERS TO GRADE IN PAVEMENT F.G. EL: 19.0(MAX.) I I, s • DOUBLE ■STONE OR fu� "' " • I i ��.i+iii` ii`�ii �•'��� '_ _ _ _ _ =' i=' ' _ _ .iii'..' - - - - - - - - - - - DB- • 3/4" - 1-1/2" DOUBLE WASHED STONE EFFECTIVE LENGTH = 42.0' INV. ELEV.= 15.1 TOP CONC. ELEV.= 16.10 INV. ELEV.= 15.10 as ease BOTTOM EL.= 13.1 SEPARATION 5.00 FT BOTTOM OF TESTHOLE EL: 8.1 SEPTIC SYSTEM PROFILE N.T.S. DESIGN CRITERIA NUMBER OF BEDROOMS: EXISTING 5 BR TOTAL DESIGN FLOW, (2 BRS W/INJECTOR PUMP) SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 5 BR DESIGN FLOW: 550 G.P.D. GARBAGE GRINDER: NO (not designed for gorboge grinder) SEPTIC TANK: 550 gpd x 200% = 1,100 gpd, EJECTOR PUMP 2 OF 5 BEDROOMS, 40% FLOW USE NEW 2,500 GALLON (1,500/1,000) SEPTIC TANK, MEETS 310CMR15.229(2) LEACHING AREA REQUIRED: (550)/0.74 = 743.24 S.F. USE FOUR (4) 500 GALLON H2O PRECAST LEACH CHAMBERS W/ 4' STONE ON ALL SIDES: 42' L x 13' W x 2' D BOTTOM AREA: 42 x 13 = 546 SF SIDE AREA: (42 + 13) X 2 X 2 = 220 SF TOTAL SQUARE FEET PROVIDED = 766 vs. 743.24 REQ'D DESIGN FLOW PROVIDED: 0.74(766 S.F.) = 566 G.P.D. vs. 550 G.P.D. req'd a BREAKOUT ELEV.= 16.10 4' _I E 5 FT. 4� EFFECTIVE WIDTH = 13' (500 GALLON H2O LEACH CHAMBER) SOIL LOGS DATE: SEPTEMBER 23, 2015 SOIL EVALUATOR: DARREN M. MEYER, RS, CSE WITNESS: AMY VONHONE, YARMOUTH HEALTH Elev. TP- 1 Depth 19.10 A 0" LOAMY SAND 18.18 OYR 11" B LOAMY SAND 10YR 6/8 15.77 40" C 1 MEDIUM SAND PERC TEST i 2.5Y 6/4 12.28 i 8.1 132" PERC RATE <2 MIN/IN. (-Cl- HORIZON) NO GROUNDWATER OBSERVED * 1, Darren M. Meyer, R.S., CSE, hereby certify that I am 'currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis !has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that] I have passed the Soil Evol. Exam in October, 1999. GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS NOTED BELOW: VARIANCE FROM 310CMR15.229(2): TO ALLOW EJECTOR PUMP TO PUMP 40% OF DAILY FLOW VS. 25%, FULL COMPLIANCE WITH 310CMR15.229 PR( 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON NAVD DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWELLING IS SERVICED BY MUNICIPAL WATER. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING CESSPOOLS TO BE PUMPED, CRUSHED AND FILLED BY HAND PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 Fr. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 0 1 /8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. 01 1140 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 28 CHARLES STREET, SOUTH YARMOUTH, MA Prepared for: Jenney System Design and Site Plan by: SCALE DRAWN DATE MEYER& SONS, INC. N.T.S. DMM 10/16/15 PO BOX 981 E41STSAA(DWICH,MA02637 REV DATE CHECKED SHEET NO. 508-362-2922 11/10/15 DMM 2 of 2