Loading...
HomeMy WebLinkAboutEngineered Plans - 2015BED BATH KITCHEN ROOM LIVING BED ROOM ROOM MAIN FLOOR UNFINISHED L MILYOOM BASEMENT YARMOUTH. MA LOCUS MAP EL EVA TIONS ELEVATIONS SPECIFIED ARE INVERT ELEVATIONS (BOTTOM OF PIPE) EXPRESSED IN DECIMAL FEET SEWER LINE OUT 41.5+— SEPTIC TANK IN EXISTING SEPTIC TANK OUT 39.85 D—BOX IN 38.95 D—BOX OUT 38.78 LEACHING SYSTEM IN 38.75 BOTTOM OF LEACHING 36.75 DATUM ASSUMED°�/� ELEVATION O %T 4 3.75 SPOT ON CONCV�'' THIS IS A COLOR PLAN USE COLOR PLAN ONLY FOR INSTALLATION FULL DETAIL IS BEST VIEWED IN FULL COLOR 41 42 do ' ' I I ' n����&-m-� LOT �1®6' AREA = 12600 sf+— PLAN BOOK187 PAGE 31 PLAN SCALE: I in = 20 ft PRINT ON 8-1/2 x 14 in PAPER FOR PROPER SCALE THIS PLAN IS INTENDED SOLELY FOR INSTALLATION OF THE SEPTIC SYSTEM DEPICTED ON IT. FOR ANY OTHER CHANGES TO THE PROPERTY INCLUDING PLACEMENT OF ADDITIONS, SHEDS, FENCES OR SWIMMING POOLS, OWNER SHOULD CONSULT WITH A MASSACHUSETTS REGISTERED LAND SURVEYOR. J SEWAGE DISPOSAL SYSTEM PLAN OF *SS9 -TO SERVE EXISTING DWELLING DAVID �yGs D. COUGHANOWR No. 461 \/'PROVES a CATERINO OWNERIS7 OF RECORD 'l 58 MADISON AVENUE YARMOUTH, MA 155 Geo Ryder Rd S PROPERTY ADDRESS Chatham, MA 02633 Davidcou®Hotmail.com IDATE, OCTOBER 30. 2015 508.364-0894F-FG—i—/2-11 JOB, ETE-4003 DEPTH INCHES NOT TO SCALE SOIL HORIZON USDA SOIL TEXTURE SOIL COLOR (MUNSELLI SOIL MOTTLES OTHER SOIL EVALUATOR: DAVID D. COUGHANOWR. ASE 0461 WITNESSED BY: AMY VON HONE. HEALTH DEPT. TEST PIT 1 NO72In-NnCCH OILS SANDY LOAM 10 YR 3/2 NONE FRIABLE IN C ELEVATION 10 YR 4/2 NONE FRIABLE 15-22 A LOAMY SAND 10 YR 4/4 NONE FRIABLE 42.25 B LOAMY SAND 10 YR 5/8 NONE FRIABLE 42-162 C MEDIUM SAND 10 YR 5/4 NONE LOOSE 38.75 28.75 DEPTH INCHES NOT TO SCALE SOIL HORIZON USDA SOIL TEXTURE SOIL COLOR (MUNSELLI SOIL MOTTLES OTHER 0-9 FILL N m 23.46 STONE 3.75 ft 8.5 ft 3.75 ft 500 GALLON DRYWELL 9-13 Ap SANDY LOAM 10 YR 3/2 NONE FRIABLE 13-15 E LOAMY SAND 10 YR 4/2 NONE FRIABLE 15-22 A LOAMY SAND 10 YR 4/4 NONE FRIABLE 22-42 B LOAMY SAND 10 YR 5/8 NONE FRIABLE 42-162 C MEDIUM SAND 10 YR 5/4 NONE LOOSE DESIGN FLOW: 2 BEDROOMS X 110 GPD = 220 GPD SEPTIC TANK- 220 GPD X 2 DAYS = 440 GALLONS USE EXISTING 1000 GALLON SEPTIC TANK IF IN SOUND STRUCTURAL CONDITION. IF NOT. INSTALL NEW 1500 GALLON SEPTIC TANK. DISTRIBUTION BOX: INSTALL UNIT DEPICTED BELOW. SOIL ABSORBTION SYSTEM: THE LONG TERM ACCEPTANCE RATE FOR A CLASS ONE SOIL WITH A PERCOLATION RATE BELOW 5 MINUTES PER INCH = 0.74 GALLONS PER DAY PER SQUARE FOOT. THE 16 ft x 12 ft x 2 ft LEACHING GALLERY DEPICTED CAN LEACH: BOTTOM AREA = (16 x 12) = 192 sq. ft. I A AREA =(16+16+12+12) x2 =112so. ft. TOTAL AREA = 304 sq. ft. FLOW CAPACITY = 0.74 x 304 = 224.96 gal/day INSTALL A 16 ft x 12 ft x 2 ft GALLERY AS CONFIGURED BELOW. FLOW CAPACITY = 224.96 gal/doy WHICH EXCEEDS THE 220 gal/dog REQUIRED FOR A TWO BEDROOM DESIGN. INLET COVER 5 ft - 8 in OUTLET COVER O -BOX SEPARATION BETWEEN INLET &OUTLET TEES NO LESS THAN LIQUID DEPTH CROSS SECTION VIEW <i in ,1,. 12 /n MIN � FROMLIMS TANK�pTO ^ SAS �ltS�P 6 In STONE BASE CROSS SECTION VIEW SO = PT O SYSTEM USE SHOREY PRECAST 500 GALLON LEACHING DRYWELL DRYWELL 16.0 ft UNITv m m " READING DATE o- N m 23.46 STONE 3.75 ft 8.5 ft 3.75 ft 500 GALLON DRYWELL DIMENSIONS & DETAIL INSTALL ONE INSPECTION ^ RISER TO WITHIN THREE INCHES OF FINAL GRADE 6 INDICATE LOCATION ON AS -BUILT 36' in H 20 102 in INSTALLER MAY SUBSTITUTE AN APPROVED GEOTEXTILE FABRIC IN PLACE OF THE 2 In. PEASTONE LAYER SPECIFIED. CROSS SECTION VIEW 2 h FE4STOAE 2 h PEASTCAE 24 in 28 4 h TO EFFECTIVE 3N h T [26 in F1/2 h �1 DEPTH Y2 h GRA n 45 in 58 in 45 in .148 fn_ -INSTALLER II0 OBTAI IS 5 PEA 7 BEFORE STARTING WORK -ALL COMPpNENTS INSTALLED SHALL MEET THE MINIMUM r REQUIREMENTS OF MASSACHUSETLSjjTLE ,5_.SEP.TLC-.. CODE (810"CM ` b): -INSTALLER O V�� LOCATIONS OF ALL UNDE06UND UTILITIEURFORE--.EXCAV.ATING FOR SYSTEM. - --- -ECO-TECH ENVIRONMENTAL RECOMMENDS THE INSTALLATION OF LOW FLOW FIXTURES & APPLIANCES. AND PERIODIC PUMPING OF THE SEPTIC TANK. -SEPTIC TANK NOT DESIGNED TO WITHSTAND VEHICULAR LOADI DO NOT PARK OR DRIVE VEHICLES OVER SEPTIC SYSTEM. OBSERVED GW NONE AT 28.75 INDEX WELL AIW-230 ZONE C READING DATE SEPTEMBER 2015 READING 23.46 ADJUSTMENT 2.96 ADJUSTED OW BELOW 31.71 �F L OO W R OO F I L E 1111 TOP OF FOUNDATION RAISE COVERS TO WITHIN ALL PIPE TO BE SCH. 40 PVC VENT EL = 43.42 \ in OF FINAL GRADE AND TO PITCH AT 1/8 In/ft MIN PIPE �b �� J� �� 42.75 �� J� J� J� J� J, D -BOX I I I I' I SE I 11 3 H-20 USE H-20 1 EXISTING 39.75 MAX RST 1000 GALLON PRECAST lYd� SEPTIC TANK 39.85 6° DRYWELL 38.786 In r��u I EXISTING REFER TO DETAIL BOX STONE SOIL ABSORPTION + 38.95 BASE 38.75 6 In STONE BASE IF NEW SYSTEMA —REFER TO O EXISTING 86 ft 5 ft DETAIL BOX � ADJUSTED SEASONAL BELOW 36.75 HIGH GROUNDWATER _ 31.71 SEWAGE DISPOSAL SYSTEM PLAN 58 MADISON AVENUE YARMOUTH. MA (OCTOBER 30. 2015 ; ETE-4003 PG 2/2'