Loading...
HomeMy WebLinkAboutEngineered Plan - 1998SEPTIC PROFILE T.O.F. AT EL. 33.09' (NOT TO SCALE) ACCESS COVER TO WITHIN 6" OF FIN. GRADE 18x5 ACCESS COVER (WATERTIGHT) TO / 31 0' WITHIN 6" OF FIN. GRADE MINIMUM .75' OF COVER OVER PRECAST 'J2 j' (EXIST.) Geo RUN PIPE LEVEL R FOR FIRST 2' 31.19.19 PROPOSED 1500 tiy�, � � CULTEC FILTER FABRIC PER SPECS OVER I v_ LEACH FACILITY GALLON SEPTIC29 0' I TEE 29.25 10 2% SLOPE REQUIRED OVER SYSTEM 32.0' 0.75' 31.26' TANK (H- ) GAS «' 31.02 AFFLE 31.19' � CULTEC TEC C4 FIELD DRAIN PANELS 30.60' (7.7 % SLOPE) �6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) O" DEPTH OF FLOW = 4' ( 1 %SLOPE) ( 1 % SLOPE) 3/4" TO 1 1/2" DOUBLE WASHED STONE'/// TEE SIZES: INLET DEPTH = 10" OUTLET DEPTH = 14 FOUNDATION- 25' LEACH FIELD DETAIL (NTS) .0' 24" OAK 30' CROWN ST 12' PC 4' D' BOX SEPTIC TANK AND PUMP - CHAMBER REQUIRED TO BE WATER -PROOFED 4.0' 7" 11' LEACHING -" FACILITY * ADJ. 26.60' 23" WATER 0.77' ADJ. 30.0 LOT 284 A25.83' to OBSERVED WATER 35' 31.4 120 p4 \3� It,p WELL MIW-29 ZONE B ADJUSTMENT 1.7' tip 31. 31 0 ;?� 'k NOTE: WATER LEVEL_ NEVER HIGHER THAN 4' ABOVE BENCHMARK GAS 2 .8 SLAB IN BASEMENT PER OWNER, WHICH CORF'=LATES 12O" METER TO ABOUT 1/2 THE FULL ADJUSTMENT TEST HOLE LOGS ENGINEER: DAVID MASON, RS WITNESS: RON CADILLAC, RS (BOH) DATE: 9/20/96 PERC. RATE _ <2 MIN./INCH CLASS I SOILS P# N/A Q ELEV. 31 .0' A SANDY LOAM 10 YR 3/2 B LOAMY SAND 10 YR 5/8 Cl FINE LOAMY SAND 10YR 6/8 C2 FINE SAND 10YR 7/8 observed Q water 29.1' perc 25.83' 21.0' Q �u c o -77 S,.,4 a L- GA yG741' M� L::�LOCATI�ONMAP �NOSCALE ASSESSORS MAP 59 PARCEL B283 SETBACKS: N/A (EXISTING DWELLING) FRONT = SIDE _ REAR - REF. PB 208 PAGE 87 FLOOD ZONE: C COR F TOP os TEP ?' NOTES EXISTING (THIS LEVEL IS TF-EREFORE UTILIZED IN THE DESIGN) ROW OF 31 2 HOUSE #25 E TF = 33A9' '1 CATCH EVERGREENS �� w * , TJ BAS;NS 1. DATUM IS ASSUMED FROM DENNIS QUAD MAP - - - WD ti z� (1 _._./ .....! - - - _ _!_._.. _��..^---•� __.__-_`� iTl --__ _.___- ___ �..__ - rji_.i i... 1,1��,�,e. c ., ..�_ .. �._ - - l=i•�IJ IiIVV n... - 0 F . NOT '�I_I , t -_ vv ` / 2. MUNICIPAL WATER 15 _ i .. S T ` _ 1.5. INVERT OUT ` 't29.6 + ! n D SIGN FLOW: 3_ BEDROOMS (110 GPD) = 330 GPD i�31.1 _ 31.3 ELEV = 31.19' - 3. MINIMUM PIPE PITCH TO BE 1 /8" PER FOOT. CONCU<;E q _3_3_0 GPD DESIGN FLOW SHED PATIO ' 31.E 2 = 660 GALLONS 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 30.9 CONC i t-' SEPTIC TANK: 330 GPD (___) 5. PIPE JOINTS TO BE MADE WATERTIGHT. a18' PINE WALK 31.5 --- � '- 31.6 3?� �� 2 �, � U`aE A 1500_ GALLON SEPTIC TANK 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. VENT m 31.1 ` ti) PC 31.4 BASE. SLAB \ -- �, n �, 38' 0 EL. 26.27' \\ - 0 Ll' CHING: ENVIRONMENTAL CODE TITLE V. _ 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE _ GPD USED FOR LOT LINE STAKING. Q , x 32. / S' DES: -------------- (---) _ --- „ 30 29'9 74 = 333 GPD 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4 PVC. 5' REMOVAL OF UNSUITABLE SOIL 1 REQUIRED AROUND LEACH FACILITY, DOWN TO Cl LAYER. REPLACE WITH CLEAN MED. SAND. ENGINEER TO INSPECT AND CERTIFY REMOVAL CONTRACTOR TO CONFIRM SUITABLE SOILS IN AREA OF LEACH FACILITY PRIOR TO CONSTRUCTION OF ANY PORTION OF SYSTEM Tn7711 nn 0 0 n 1 0 C4 C4 EXIST. POOL Or 3 .6 (TO BE -n C4 C4 REMOVED) z 32.0 x C4 C4 7c 31. 31. X y ---"X STOCKADE FENCE , 120.00 9 LOT 282 -- BoTTOM:--30 x 15 ------ (---) - ---- 333_ GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT 32 �'I -- TOTAL: 450_ S.F. --- INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED 1 31.0 %, USE 2 ROWS OF (3) C4 CULTEC FIELD DRAIN PANELS EACH, FROM BOARD OF HEALTH. 32._ '1 10. CESSPOOLS TO BE PUMPED AND FILLED WITH CLEAN SAND OR WITH 3' OF STONE AT ENDS AND BETWEEN ROWS; USE 2' AT SIDES REMOVED AS NECESSARY. LEG N D 1 1 . D'BOX IS TO BE WATER -TESTED FOR LEVELNESS LOT 283 , Area = 12,960 sq.ft � 0.30 Acres 12. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR T 100.0 PROPOSED SPOT ELEVATION CONSTRUCTION 30. 13. ELECTRICAL PERMIT REQUIRED 100x0 EXISTING SPOT ELEVATION UPGRADE SITE AND SEWAGE PLAN 100 PROPOSED CONTOUR - OF ** EXACT UOF GASAND WATER M LOCATIONS 1 OO EXISTING CONTOUR #25 CAPTAIN PERCIVAL DRIVE LINES NKNOWN. PRIOR TO CONSTRUCTION IN THE TOWN OF: EXISTING TREE MASS. (SOUTH) YARMOUTH, ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE' BUILDING. ALARM TO BE ON INV. IN 31.23' . TO O'BOX SEPARATE CIRCUIT FROM PUMP 1000 GAL. H-10 S 800 GAL.+ WEEP LE ALARM ON RESERVE FLOAT SWITCH SETTINGS: PUMP ON 4" WORKING RANGE 8" ZOELLER "WASTEMATE" .4" SUBMERSIBLE MODEL M282 1/2 HP PUMP PUMP OFF 4" SYSTEM (OR EQUAL) 6" CRUSHED STONE OR COMPACTION PUMP CHAMBER (NOT TO SCALE) BOARD OF HEALTH PREPARED FOR: VIOLET PINKHAM MA APP OVER AT 20 0 ZO 40 60 Feet off 508-362-4541 fox 508 362-9880 down cape engineering, inc. CIVIL ENGINEERS i. LAND- SU­RVE:y-QRS;.. , 939 main st. yarmouth, ma 02675 SCALE: 1" = 20' DATE: iv v -n H. OJA LA, 'jvuf- amu- vc.� , a .r SEPTEMBER 11, 1998 SEP 17 1999 HEAL I H DP -PT. 'S. 19) i99q ---- DATE