Loading...
HomeMy WebLinkAboutApp# 4341GENERAL NOTES: I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. , J. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 4. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 5. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1-800-322-4844 AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 6. VERTICAL DATUM IS: ASSUMED 7. FOR BENCH MARKS SET. SEE SITE PLAN. 8. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS, SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. 9. 1T SHALL REMAIN THE CLIENT'S RESPONSIBILITY To HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. 10. ALL UNSUITABLE MATERIAL (A A B HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. L �Ee FOLL INS G POND �y IRAI - LOCUS MAP 101.4+ lor.oe/ 1oo.a4� / i r eEN31 MARK f PK MAIL IN ROAD EL -100.00 99.e .' �'1Dos•}, +i 99.7+ i PROPOSEDIIDR1 E 11-1- 0.1 41, t 1 eDSE° / N ----. r --- i 3-4'x e' FLOYDIFFUSORS V/4' JTONE AROf4VD 99�t Zo ...........i /------- k7. / D-ePX--- PROPOSED THREE SEDROON DWELLING 97.7+ LOP . 102 _ a h 22 / SEPTIC 74YR 1 01.4+ DESIGN CRITERIA: DESIGN FLOW: -3 BEDROOMS ATJLLO-G. P. D. PER BEDROOM EQUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 20OX - 660 GAL, SEPTIC TANK PROVIDED 1500 GAL. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE -MIN/INCH SOIL TEXTURAL CLASS - -I EFFLUENT LOADING RATE -_0,1_4 GPD/SF 330 GPD / 0, 74GPD/SF - 446 S.F. PROVIDED:_3-4'x 8' FLOWDIFFUSORS -W/4'STONE AROUND. A-472 S.F. SOIL TEST PIT DA TA INDICATES 7_ INDICATES PERCOLATION = OBSERVED GGGSSi TEST GROUNDWATER TP• I TP• 2 GRND EL.97•9 GRND FL. 96.8 G. W. EL . 85.9 G. W. EL. N/A 0' HORIZON TEXTURE COLOR OTHER 97.9 0' HORIZON TEXTURE COLOR OTHER 96.6 0 0 3 •!.............................................................: 97.7 3............................................................. 96.6 LOAMY /OYR LOAMY IOYR Q SAND 3/2 ASAND 3/2 9 • �............................ .............................. 97.2 7 • ............. ... ..................... 96.2 B LOAMY IOYR p LOAMY IOYR SAND............ 4/4.... SAND............ 4/4..:. ................. 94.8 22 ................... 95.0 37' C MEDIUM 10 YR COBBLES C I SANDY IOYR COMPACT " SAND 7/4 GRAVEL LOAM 7/1 64-� (LOAMY) 54' ....................... 92.3 C2 MEDIUM IOYR COBBLES SAND 7/4 GRAVEL / 85.9 85.4 120' DATE: JULY 3. 1996 TEST PY: STEPHEN HAAS WITNESSED BY: ROV CADILLAC PER P4 TE: ( 2 MIN/INCH 86.8 SEP T / C S YS TEM INVERT ELEVATIONS: ACCESS COVERS MUST BE WITHIN 9' MINIMUM. INVERT AT BUILDING: 96.5 WAY 6' OF FINISH GRADE 3' MAXIMUM COVER INVERT IN SEPTIC TANK: 96.0 FIRST 2' TO /,",- BE LEVE L MIN 2' OF PEASTONE INVERT OUT SEPTIC TANK: 95.75 4' PVC , INVERT IN DIST. BOX: 95.42 3/4' - I //2• DIA. HEDULE 40 94.0 WASHED STONE INVERT OUT DIST. BOX: 95.25 o S- 95 3-4 'X e' FtowDlFFusoRs !EVERT 1N LEACH CHAMBER: 95.0 BAFFLE 3 OUTLET W/4' STONE AROUND. 12'X 32' BOTTOM OF LEACH CHAMBER: 94.0 l0' MIN. 1500 GAL D -BOX ADJUSTED GROUND WATER: 89.0 SEPTIC TANK 6' CRUSHED STONE BASE OBSERVED GROUND WA TER: 85.9 BOTTOM OF TEST HOLE *1: 85.4 PROF I L E : NOT TO SCALE INDEX WELL AIW 247. ZONE B 6/96 - 23.8. 3.1' ADJUSTMENT 101.4+ lor.oe/ 1oo.a4� / i r eEN31 MARK f PK MAIL IN ROAD EL -100.00 99.e .' �'1Dos•}, +i 99.7+ i PROPOSEDIIDR1 E 11-1- 0.1 41, t 1 eDSE° / N ----. r --- i 3-4'x e' FLOYDIFFUSORS V/4' JTONE AROf4VD 99�t Zo ...........i /------- k7. / D-ePX--- PROPOSED THREE SEDROON DWELLING 97.7+ LOP . 102 _ a h 22 / SEPTIC 74YR 1 01.4+ DESIGN CRITERIA: DESIGN FLOW: -3 BEDROOMS ATJLLO-G. P. D. PER BEDROOM EQUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 20OX - 660 GAL, SEPTIC TANK PROVIDED 1500 GAL. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE -MIN/INCH SOIL TEXTURAL CLASS - -I EFFLUENT LOADING RATE -_0,1_4 GPD/SF 330 GPD / 0, 74GPD/SF - 446 S.F. PROVIDED:_3-4'x 8' FLOWDIFFUSORS -W/4'STONE AROUND. A-472 S.F. SOIL TEST PIT DA TA INDICATES 7_ INDICATES PERCOLATION = OBSERVED GGGSSi TEST GROUNDWATER TP• I TP• 2 GRND EL.97•9 GRND FL. 96.8 G. W. EL . 85.9 G. W. EL. N/A 0' HORIZON TEXTURE COLOR OTHER 97.9 0' HORIZON TEXTURE COLOR OTHER 96.6 0 0 3 •!.............................................................: 97.7 3............................................................. 96.6 LOAMY /OYR LOAMY IOYR Q SAND 3/2 ASAND 3/2 9 • �............................ .............................. 97.2 7 • ............. ... ..................... 96.2 B LOAMY IOYR p LOAMY IOYR SAND............ 4/4.... SAND............ 4/4..:. ................. 94.8 22 ................... 95.0 37' C MEDIUM 10 YR COBBLES C I SANDY IOYR COMPACT " SAND 7/4 GRAVEL LOAM 7/1 64-� (LOAMY) 54' ....................... 92.3 C2 MEDIUM IOYR COBBLES SAND 7/4 GRAVEL / 85.9 85.4 120' DATE: JULY 3. 1996 TEST PY: STEPHEN HAAS WITNESSED BY: ROV CADILLAC PER P4 TE: ( 2 MIN/INCH 86.8 SEP T / C S YS TEM OES / GN 38 N / CKE-RSON FARM WAY SOUT/-H YAAeMOUTH. - "AZL . }, - ,_� PREPARED FOR L v, i 7 CN 17.7402 S.F. W D O UGL 14 S S HER MA Nco. BOX 938 . WE,5 T OENN MA 02670 SCALE: / 20 .JUL Y 27. 1996 'E.4GLF SURT/E'YING 8L E'NG INE"�RING . INC . X923 RO u r e CA Yarmouth Or t AfA 0.? _ 5®% 3 6 2 - 1 3 2 APPROVED YARMOUTH COMM) - �50e 432-5333 Kw6RD�m o 10 20 40 JOB NO: 96-305 FIELD:RVB/FCR CALC: SAH CHECK: CFW DRN: SAH j