Loading...
HomeMy WebLinkAboutEngineered Plans - 2015RETA/N EX/ST/NG /000 GALLON SEPT/C TANK so 50.00 O //4z SCALE. • 1 "= 20' 0 20 40 60 Install Two—Way 4 -Clean Out To Grade Sh t: I of2 PROPOSED LEACH/NG AREA 25.0' X /2.8' X 2.0' (H-/0) N LOCUS i nrA TinAi Assessors Map 723 Parcel 73 Deed: Bk. 7 0083, Pg. 71 Plan: Bk.209, Pg. 1,35 Lot 29 9_Y1QT/A/r' 97 nnP /A Ynl /T MaRAN ENGINEERING ASSOC.,LL 508-432-2878 941 MAIN STREET (RTE 28), HARWICH, MA SEPTIC SYSTEM DESIGN PLAN IN YARMOUTH Prepared For: Lillian Sparks 22 SQUIRREL RUN YARMOUTH PORT MA PROJECT: 15-227 1 SCALE.- 1 "= 20' DATE: 10/30/15 {•- 10, --�I r-- 115' I I Z T.O.F. ACCESS MANHOLES TO . W/THIN ELEV. 52.3 EXIST. 6" OF FIN/SHAD GRADE' ELEV. 49.3 SET ELEV. 49.1 o U �-.� 10" ............... .....................................:.............. . GAS : e000 dfl epee ....... 14" BAFFLE eee=eee=ee= oeeooeeeoeo EXIST. eoeeoeeeooe oeeeooeovee EXISTING 1000 GAL. SEPTIC TANK Replace Tees If Corroded 1 C� .................. ................ 4'ends�,� 2 Chambers, 17' _,_4'ends 4'sides T 4'sides SYSTEM PROFILE Not to Scale SYSTEM DESIGN w Design Flow: *3 bedrooms ..� 110 ,gal/day,_.. 330 gol. Septic Tank: 330 gal. is 2007 = 660 gal Use Existing 1000 Gal. Tank Leaching Facility: 12.8'x25.0'x2.0'd Chamber and Stone SAS Bottom: 12.8'x 25' x 0.74 Gal/SF= 236 Gal Sides: (12.8'+25')x2'x2x0.74Gal/sf=111 Gal ��TOTAL = 347 Gal. * Existing dwelling contains 2 bedrooms, 330 GPD minimum allowable design per 310CMR 15.203(2) Note: Garbage disposal is not permitted with this design. SEPTIC SYSTEM NOTES 12.8' x 25.0' x 2.0' Deep 500 Gal. Chamber & Stone LEACHING FACILITY EXISTING SEWER ELEVATION IS TO BE VERIFIED PRIOR TO THE INSTALLATION OF NEW SYSTEM COMPONENTS. EXISTING 1000 GALLON SEPTIC TANK IS TO BE PUMPED AND RETAINED. INLET AND OUTLET TEES ARE TO 'BE REPLACED CORRODED. INSTALL RISERS TO WITHIN 6" OF FINISH GRADE. EXISTING LEACH PIT IS TO BE PUMPED AND FILLED. INSTALL 4" PVC TWO-WAY CLEAN OUTS TO GRADE ON PIPE RUNS OF MORE THAN 50' AS SHOWN. A 5' UNSUITABLE SOIL OVER -DIG IS REQUIRED TO MINIMUM EL. 37.1 (2C SOIL LAYER. COARSE SAND). DESIGNER SHALL NOTIFIED FOR INSPECTION PRIOR TO PLACEMENT OF TITLE 5 FILL. ALL COMPONENTS ARE TO MEET TITLE 5 MATERIAL & CONSTRUCTION REQUIREMENTS. SYSTEM COMPONENTS ARE TO BE SET ON A STABLE, COMPACTED BASE. DISTRIBUTION BOX EXIT LINES ARE TO BE SET LEVEL FOR THE FIRST 2'. DESIGN ENGINEER IS TO CERTIFY SOILS OF ALL SAS EXCAVATIONS PRIOR TO BACKFILLING. DESIGN ENGINEER IS TO CERTIFY SYSTEM INSTALLATION (LOCATIONS & ELEVATIONS) PRIOR TO BACKFILLING. filter fabric or 1/8' to 1/2' doubled washed stone 3/4' to 1112 doubled washed stone 7.9' ELEV. 32.3 Btm. TH NO G.W.E. SAS CONSTRUCTION DETAIL 500 GAL. LEACHING CHAMBER STONE --- ------------------------ -- -1 1 4.0' i 12.8'0 0 ; 4.8' 4.0' L-------------------------------- J t �4. O'w -- 8.5' -- - 8.5' -- 4.O'� 25.0' TEST HOLE I El. 44.7 Elev. Depth Horizon Texture Color Other 0-4" A/E Loamy Sand 7.5YR4 3 Granular 44.3 Loamy 4-34" Bw Fine Sand 10YR56 / M. V, Friable 41.8 Loamy 34-52" B/C Fine Sand 10YR4/6 M.V.Friable 40.3 Loamy Medium San d 10YR5 4 / Loose 52-90" C w/ mixed layer 2.5 Y514 Firm Sandy Loam 37.1 Coarse Sand 10YR5/6 Loose 90-148" 2C w/ band Very 2.5Y6/2 single grain Fine Sand Btm EL 32.3 No Groundwater Found Date: 10/29/15, Performed By: Rick Judd, SE, Witness. A. VonHone, HA IF Percolation rate assumed <2 min/inch in 2C layer BE COMPONENTS ARE TO BE WITHIN 3' OF FINISH GRADE & ARE TO HAVE A MINIMUM OF 1' OF SOIL COVER. ACCESS MANHOLES ARE TO BE WITHIN 6" OF FINISHED GRADE. ALL AREAS DISTURBED BY CONSTRUCTION ARE TO BE GRADED, LOAM COVERED AND SEEDED.