Loading...
HomeMy WebLinkAboutEngineered Plans - 2015LEGEND SOUTH YARMOUTH }-� PROPOSED CONTOUR 9® PROPOSED SPOT GRADE I --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE � Off, W— EXISTING WATER SERVICE by S'� KNOB HILL RD. TEST PIT U 6 N D A ! 5Y LANE SCALE: 1"=20' WITES PATH c", .\ 80.63' N I Yarmouth Health Department = LOCUS MAP PP VED 0.22 ACRES UJ 7 LOCUS INFORMATION N I Q I ame Date TITLE REF: SK 27654 PG 121 zwc�- PARCEL ID: MAP 110 PAR. 026 3 I o I I I ' I I I I SEPTIC SYSTEM NOF REPAIR PLAN LOCATED AT: T.O.F. @ EL. 100.5 $RU "`"` G 17 DAISY LANE ANO' ' SOUTH YARMOUTH, MA 'RelIr+�a PREPARED FOR `l DAVID & HELEN 99.2DECK ��- �.�� PRIEST 99.3 i OCTOBER 26, 2015 c 19.3 N a8.0 97.5 TBM EL. 99.3` OF59� BULKHEAD FOUND. E'�t 3T Str J�T1G T�}'N!L � �� � ���� ( o s DA N M (To R�MMN� \ BED BED L/V o 99.7 � 1 0 ' ROOM ROOM ROOM 11 99.8TP b N \98.06/Sim° � P 9. , i GARAGE BED BATH SA81TA?0 ( . �b ' ROOM BATH KIT --1 w MEYER & SONS INC. 99.8 i 98.1P.O. ! BOX 981 G9.20FLOOR 99 ° PLAN E. SANDWICH, MA 02537 PH. (508)360-3311 FAX: (774)413-9468 meyerandsonsinc@gmail.com I SHEET 1 OF 2 J#1660 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS T.O.F. NOTE: PLACE RISERS OVER ALL COVERS W/IN 6" OF GRADE EL: 100.50 F G.EL: 99.3 /- r- F.G.EL: 99.40 F.G. EL: 99.10 EX TOP TANK=EL. 98.45 10"I TEE'S ARE TO BE 4" SCH 40 PVC FINISHED GRADE (99.0) MAINTAIN 2% MIN SLOPE OVER LEACHING AREA 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC 4" SCH 40 PVC 3/4" - 1-1/2" DOUBLE WASHED -------------------- N Ni .................. ........................... M gzip. '� :::::•+i�:::••::•'� •ice -i ice_ �_ •� +`��"i:�:i �iti�:i .95 INV. 97.18 •• ,BAFFLEJ • GAS J i ;PROPOSED D: DISTRIBUTION:• EL. 97.83 J INV. 97.43 EXIST. 1,000 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK WITH IGALLON SEPTIC TANK IF FAILED, SEPTIC SYSTEM PROFILE DAMAGEDED,, NOT H2O LOADING, OR UNDERSIZED. 4) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. - 4.-ANY--CONDITIONS-ENCOUNTERED-DURING-CONSTRUCTION-DIFFERING - -- - - --- - FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING CESSPOOL TO BE PUMPED, CRUSHED, REMOVED AND FILLED PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12, THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO ABUTTING PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPECIFIED) SOIL: LOGS INV. ELEV.= 96.60 TOP CONC. ELEV.= 97.10 INV. ELEV.= 96.10 - BOTTOM EL.= 94.10 SEPARATION 5.50 FT. BREAKOUT ELEV.= 97.10 ®� E3 E3 ®®®®®®® ®®®®®®® ®®®®®®® 3.75' I 5 FT. L 3.75' 1-rE EFFECTIVE WIDTH = 12.5' BOTTOM OF TESTHOLE EL: 88.60_L- SOIL ABSORPTION SYSTEM (SECTIONi DATE: OCTOBER 14, 2015 SOIL EVALUATOR: DARREN MEYER, CSE 1614 WITNESS: AMY VONHONE, YARMOUTH HEALTH Elev. 99.10 TP -1 Depth 0" A LOAMY SAND 1OYR x,3/1 98.28 10" B LOAMY SAND i 10YR 5/8 96.78 28" C MEDIUM BOTTOM SAND PERC ® EL. 95.10 2.5Y 7/3 (30% BOULDERS) 88.60 126" PERC RATE <2 MIN/IN. ("C" HORIZON) NO GROUNDWATER OBSERVED } I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam in October, 1999. (500 GALLON LEACH CHAMBER) DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 3 BR = DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 330 gpd x 200% = 660 gpd;-USE EXIST. 1,000 GAL. SEPTIC TANK LEACHING AREA REQUIRED: (330) = 445.94 S.F. .74 USE TWO (2) 500 GALLON PRECAST LEACH CHAMBERS W/ 4' STONE ON ENDS & 3.75' STONE ON SIDES: 25' L x 12.5' W x 2'D BOTTOM AREA: 25' x 12.5'= 312.50 SF SIDE AREA: (25 + 12.5) X 2 X 2 = 150 SF TOTAL SQUARE FEET PROVIDED = 462.50 vs. 445.94 REQ'D DESIGN FLOW PROVIDED: 0.74(462.50 S.F.) = 342.25 G.P.D. vs. 330 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 17 DAISY LANE, SOUTH YARMOUTH, MA Prepared for. Priest System Design and Topography Plan by: SCALE DRAWN MEYER &SONS, INC. N.T.S. DMM PO BOX 981 DATE CHECKED SHEET NO. EAST SANDWICH, MA 02537 508-362-2922 11/02/15 DMM 2 of 2