HomeMy WebLinkAboutEnginered Plan - Rev. 2015SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE EL. 42.7' 42.0' MINIMUM .75' OF COVER OVER PRECAST PRECAST H-10 RISERS (TYP.) 2.0 EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. NOTE: MIN. WALL THICKNESS 2" 4"OSCH40 PVC PIPES LEVEL 1ST 2' PROPOSED CONTOUR 198.43 :* 10" 1500 GAL H-10 14" .� 39.09' TEE SEPTIC TANK TEE ` SLOPE OF GROUND C_Q_) 0 0 0 0 0 0 6" MIN. SUMP GAS BAFFLE',', °°o0o�o°���° 12" MIN. INT. DIM. + 4' LIQ. LEVEL (ACME OR EQUAL) ,; 38.8' 38.63' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM (2.5 % SLOPE) MIN. FOUNDATION- 13' - *NOTE: INTERIOR PLUMBING TO BE RE-ROUTED TO EXIT THE DWELLING IN LOCATION SHOWN ON PLAN VIEW. EXISTING TWO INVERTS TO BE CONNECTED INTO ONE. PLUMBER TO CONFIRM FEASIBILITY PRIOR TO INSTALLING ANY PORTION OF THE SEPTIC SYSTEM LEGEN D 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[991- PROPOSED CONTOUR 198.43 PROPOSED SPOT EL. TH1 TEST HOLE 2% SLOPE OF GROUND C_Q_) UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING ;: • . ..,..•• MAI ERTEST D BOX ?0a o0°0o o0°or.Q''° 00000000°000e'oo0o`0'0 FOR LEVELNESS 10000no^oo 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [23) (-L% % SLOPE) ( 1 SLOPE) SEPTIC TANK 4' D' BOX 5' ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORTS TO ZZ WITHIN 3" OF FINISH GRADE 2% SLOPE REQUIRED OVER SYSTEM 42.0' V V q TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 10/14/15 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 42.2' wo 11" 18" 48" 60" SIEVE 120" S 1OYR 3/1 B LS 1OYR 4/6 Ct MS 2.5Y 7/4 \C?1 \\S, *CL 2.5Y 5/4 C3 MS TRACE SILT 2.5Y 6/4 40.7' 38.2' 37.2' 32.2' NO GROUNDWATER ENCOUNTERED DCE # 15-259 16 H-20 HIGH CAPACITY INFILTRATORS EACH UNIT. 6.25' X 2.83 X 16" HIGH OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 25' X 11.3' (NO STONE PROPOSED) LEACHING FACILITY ROUTE 6A 3' 5.48' BOTTOM TH 2 EL. 32.2' BENCH MARK - CENTER OF CATCH BASIN. ELEV. = 42.3 cn-------------- 10 o \ \RICK �'A Mme• \ 6 X000 a 110. / CLEANOUT16 6' TH 1 IV EXIST. 16.0' N DWELL. 11�? a TF =42.7' 41 FULL BASE2 I I 42 - PARCEL 2 �� \�------- 6,541t SF 69 02' EDGE 2o.00, BRICKPATIO NOTE: INTERIOR PLUMBING TO BE REROUTED AND CONNECTED. PLUMBER TO CONFIRM FEASIBILITY PRIOR TO INSTALLATION OF ANY PORTION OF THE SEPTIC SYSTEM UNSUITABLE SOIL Scale:1 "= 20' 0 10 20 30 40 50 FEET NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED. 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) (REMOVE C2 LAYER) N\ INSTALLER TO CONSULT WITH OWNER ABOUT THE INTENT TO PRESERVE THE BRICK \ WALK PRIOR TO SEPTIC INSTALLATION. 1 PROVIDE 29' OF 40 MIL LINER AT 5' OFF SAS IN AREA SHOWN. TOP AT ELEV. 39.0', BOTTOM AT EL. 35.0'± 'J JI `� O 1 0 3 GRAVEL O I v PARKING 21 Q 16.71, o� V LOCUS MAP NOT TO SCALE ASSESSORS MAP 112 PARCEL 24 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 16.6') TOWN OF YARMOUTH REGULATIONS 3.7: REDUCTION SETBACK, SAS TO OPEN & SUBSURFACE DRAINS (100' TO 34.0' ON ROUTE 6A) SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 _GPD (2)_ = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER HIGH CAPACITY INFILTRATOR UNIT 330 GPD/0.74 GPD/SF = 445.9 SF LEACHING REQ'D 445.9 SF/29.56 SF/UNIT = 15.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (16) H--20 HIGH CAPACITY UNITS IN FIELD CONFIGURATION OF 4 ROWS OF 4 UNITS 16 UNITS x 29.5 SF = 472 SF > 445.9 SF 472 SF (0.74) = 349 GPD (OK) Permit valid for REPAIR 1►l I DTIC SYS`ll"EM MA ONLY; dere to State . anal I eptic variances. APPROVED DATE BOARD OF HEALTH Board. of Ilealth review and ?f)l , a) is reiluired for any future additions/rear,,:,,..,,,/alterations to TITLE 5 SITE PLAN sewage facilities ani]/or strucU,r t-,..I,%elling. OF Yarmouth llealah l)el,;i, tment APPRI N" L 17 ROUTE 6A y�y� YARMOUTH PORT, MA ame Date N OF MASS cs- 9 DANIEL A. OJALA CIVIL Cn No. 46502 P O 01ST SSS/ONAL �HOFP4,j DANIEL Z A. 0j No. 40980 P �y O�ESS�O ✓� SURV�� DATE DANIEL A. OJALA, P.E., P.L.S. PREPARED FOR PHIL ANGELLIS DATE: OCTOBER 29, 2015 REV: DECEMBER 16, 2015 (TANK LOCATION) k, off 508-362-4541 fax 508-362-9880 downcape.com d®Wn c4100e engiaedtfiftg, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOU THPOR T MA 02675 15-259 ANGELLIS.DWG