Loading...
HomeMy WebLinkAboutEngineered Plans - 2015LOCUS DATA WEIR RD. ? 0 y FA�SH OF I�gSS CURRENT OWNER THE ARLINE oaf EDWARD'cs� a LOWENTHAL TRUST W. GREAT WESTERN RD. o� A. STONE N PLAN REFERENCE 348-20 No.28980 Io LOCUS DEED REFERENCE 24348-275 s ZONING DISTRICT R-40 EXIT 8 LOCUS MAP FLOOD ZONE "X" NOT TO SCALE: 1 2$ E 18-3.54 ASSESSORS MAP 108 15-0126 N 79.43 PARCEL 43-C3B OVERLAY DISTRICT ZONE II LOT AREA 22,543± S.F. 18. s' EXISTING SEPTIC SYSTEM TO REMAIN COMPONENT REPLACEMENT PLAN '° 0 UNIT 3A UNCHANGED j � �� w o UNIT 3S L ,7/40, DES'S HILL ROAD DECK Ns m IN N YARMOUTH, MASS 38.9' EXISTING LEACHING PROPOSED NEW SYSTEM TO REMAIN 0 T U' .3 0 D=BOX AND 1500 UNCHANGED DATE: SEPT. 16, 2015 GALLON PLASTIC 22,543± S.F. SEPTIC TANK OWNER/APPLICANT: R c.te-, AR LI N E LOWEN TH AL DECK PUMP. CRUSH AND Yarmouth Health E �Z�'' D E B' S HILL ROAD z ter, J ABANDON EXISTING SEPTIC pp YARMOUTH PORT � C) � PROC.O.P. TANK WHERE POSSIBLE. MA 02675 LA Ns 97.9' Name UNIT 3B SHEET 1 OF 2 c PREPARED BY: EAS SURVEY, INC. r` 22.2' P.O. BOX 1729 SANDWICH, MA 02563 S 75432$ 0 20 30 40 PH. (508) 888-3619 CELL (508) 527-3600 GRAPHIC SCALE: EAS.SURVEY@YAHOO.COM 1 INCH = 20 FEET 20" NORWESCO SELFLOCKING COVERS TO FINISH GRADE SILL ®EL. 112.80 FINISH GRADE FINISH GRADE ELEV. 112.40 ELEV. 112.2 PROP. / //G�� C.O. TOP = 110.7 12' OF 4" PVC SCH 40 2 MI -'3' MAX 2'®S=0.04 INV.= XISTING INV.= 110.00 10"TEE 14"TEE INV.= 5'-63" INSTALL 109.75 4'-9" GAS BAFFLE 4'-6" 4'-0" LIQUID LEVEL / BOTTOM L L 0 0. " 105.25 PROPOSED 1,500 GAL SEPTIC TANK SET ON LEVEL STABLE BASE NORWESCO POLYETHYLENE 11' -11"x4' -7"x5'-6" COMPONENT REPLACEMENT PLAN #40, UNIT 3B DEB'S HILL ROAD IN YARMOUTH, MASS DATE: SEPT. 16, 2015 OWNER/APPLICANT: ARLINE LOWENTHAL DEB'S HILL ROAD YARMOUTH PORT MA 02675 SHEET 2 OF 2 PREPARED BY: EAS SURVEY, INC. 141 RT. 6A P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 RAISE COVERS TO WITHIN 6" OF FINISH GRADE /6" 3 OUTLET H-10 DB3 VV.=109.67 INV.= 109.50 GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 6" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10' OF DRIVES OR PARKING AREAS THEY MUST WITHSTAND H-20 LOADING. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO COMPONENT DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. MAGNETIC TAPE ON ALL COMPONENTS. DATUM: VERTICAL DATUM: AS -BUILT TOP OF FOUNDATION 9/24/86 BENCH MARK USED: ELEVATION 112.80 I CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. VEHICULAR TRAFFIC, PARKING OF VEHICLES AND PLACING MATERIALS OVER THE SEPTIC TANK, DISTRIBUTION BOX AND S.A.S. AREA IS PROHIBITED FINISH GRADE ELEV. 112.2 GROUND ELEVATION 112.2 10'os= 0.10 EXISTING LEACHING PIT TO REMAIN 109.2 p D D p O o 0 0 0 0 0 0 0 0 0 p D D p p pp 0 0 0 0 0 0 0 0 0 0 0 pD D D p INV.= 108.4± p p p 0 0 0 0 0 x 0 0 0 0 0 p p p p pD o a a o 0 a o 0 0 0 0 pD p D p p pD 0 0 0 0 0 a 0 0 0 0 0 pp p p p D pD a o 0 0 0 0 0 0 a o 0 pp D D D p DATUM: VERTICAL DATUM: AS -BUILT TOP OF FOUNDATION 9/24/86 BENCH MARK USED: ELEVATION 112.80 I CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. VEHICULAR TRAFFIC, PARKING OF VEHICLES AND PLACING MATERIALS OVER THE SEPTIC TANK, DISTRIBUTION BOX AND S.A.S. AREA IS PROHIBITED