HomeMy WebLinkAboutEngineered Plan - Rev. 2015H-20 CAST IRON COVER TO GRADE OVER INLET OF SEPTIC TANK 39 TOP FOUND. EL. 29.4' 22.0 SYSTEM PROFILE (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT H-20 ACCESS COVERS TO WITHIN 6" OF FIN. GRADE (IF PAVING USE CAST IRON COVERS TO GRADE) MINIMUM .75' OF COVER OVER PRECAST 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE 1 ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. H-20 CONCRETE COVER TO WITHIN 3" GRADE 2% SLOPE REOUIRED OVER SYSTEM 122.0-23.0 BLOCKS OR PRECAST H-20 RISERS (TYP.) 4"OSCH40 PVC PRECAST RISERS 2 PIPES LEVEL 1ST 2' MORTAR ALL INVERT IN 18.18' ZTCOMPONENTS 1500 GAL H-20 ENDS (TMP') SIDES 19.18' 10- " eo 18.89' TEE SEPTIC TANK TEE ' oaaa "`' 18.64' ° ° ° °o°s WATERTEST D'BOX )°°°°°°°° . ������®��OOC ®® °°°°°°°° GAS BAFFLE::, o°o°o°o°o°o° °0000 �0��00�0��� ®®�®®®®®�®� �°0000000 °C °° FOR LEVELNESS N ;00000000 �oaaaoo�ooa ®o®®®®®®®moo :00000000 4' LIQ. LEVEL (ACME OR EQUAL)..: 18 46' 18 29' °� °° °_°_°_° (_2_7. SLOPE) MIN. FOUNDATION 11 - ;000000000°o°o°o°o°o°o°0 6" MIN. SUMP I 0000°o�o�o°o°0„0000000. 12" MIN. INT. DIM. H-20 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. (2) UNITS. REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [2]) (_2_% SLOPE) ' (—L—% SLOPE) I o GROUNDWATER FOUND SEPTIC TANK 9' D' BOX LEACHING NO GR 13' FACILITY ***GROUNDWATER EXPECTED > 10' DOWN *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- - 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[99]— PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2Z; SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 10/20/15 PERC. RATE = < 2 MIN/INCH CLASS ' SOILS Q ELEV. 1 01f 24.0' A LS 20" 1OYR 4/2 B LS 30" 1OYR 4/6 21.5' C PERC MS 1OYR 7/6 132" I 113.0' NO GROUNDWATER ENCOUNTERED VCE #15-276 4 NIA I VIS NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-2.0 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. LOCUS MAP NOT TO SCALE ASSESSORS MAP 127 PARCEL 9 SITE IS LOCATED WITHIN A ZONE II VARIANCE REQUESTED UNDER MAX. FEASIBLE COMPLIANCE 15.405 1b: SAS TO BE > 3' BUT < 6' BELOW FINISH GRADE (VENT AND H-20 PROVIDED) SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD —`—"USE A— 330 -GPD DESIGN -FLOW — SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. H-20 SEPTIC TANK 4� LEACHING: � SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD r N OF SASS - �-_._`4k �OFM '`? Permit valid for RIA'AIR ()1' St=PTIt SYS"I I (11 9py.� ASSW �y ONLY; due to State.and I.ueal septic variances �o DANIEL Gs� �o��DAN(ELA.9 GJ o O•'A Ao OJALA Board. of Ilcalth review and appro�at is requited for. �� v any future additions/ren+s:�tiuos/al�crafions No. f,+1980 CIVIL V sewage facilities and/or structisres/ds+cllil�g: �o ,P gNo. 46502 mar l FEss�O a p F mouth Il�alll� 4)c1�;►rtnlent h> �h: yo GrsTE� Yar 0 S UFS Rv ti SG� _9NAL ENi�a API"RON ED Uate Scale: 1"=20' a e--1b~\� 0 10 20 30 40 50 FEET bw �__l DATE DANIEL A. OJALA, P.E., P.L.S. USE (2) 500 H-20 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 50 TASMANIA DRIVE YARMOUTH PORT, MA PREPARED FOR MARCIA GILLIS DATE: OCTOBER 27, 2015 REV: DECEMBER 16, 2015 off 508-362-4541 I fax 508-362-9880 downcape.com �o�n ca�� �n�in�@rind, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 15-276 GILLIS.DWG