Loading...
HomeMy WebLinkAbout2015 Nov 05 - Emails to D.Meyer, RS and D.Hendrick with Marked up Plan •g, �r vonHone, Amy �i From: vonHone,Amy ' Sent: Thursday, November 05, 2015 10:19 AM ' To: darren meyer Subject: 28 Charles Street � Darren- I i � I have reviewed the plan and given a copy to Conservation for review. Some of the issues that will probably ; come up on Conservation review: 1. Top of coastal bank—Kerry may require a justification of its location since it does not appear to be the first break in slope above the 100 year flood zone 2. Work limit line shown on plan , 3. Clarify the Benchmark is NAVD88 ', 4. Provide setbacks from wetland edges to the septic system � 5. Provide the elevation shots of the saltmarsh edge for us to compare to our standard groundwater EL. ' 2.5 NGVD for that wetland system ' The realtor has emailed me for a status report. I will be responding that it is still under review by Conservation and I have passed some questions on to you for clarification. � Amy Amy L.von Hone, R.S., C.H.0. ' Assistant Health Director Yarmouth Health Department 1146 Route 28 , South Yarmouth, MA 02664 ' (0)508-398-2231 X1241 ' (F)508-760-3472 � 4 avonhoneCc�varmouth.ma.us '� � � � ; i � i '� I � 1 i i .. +' i I � vonHone, Amy i From: vonHone,Amy � Sent: Thursday, November 05, 2015 10:21 AM ' To: 'David Hendrick' Subject: RE: 28 Charles St. Hi David- ' I have reviewed the plan and have passed it on to Conservation for the agent's review. There are some i questions I have passed on to the engineer for clarification and will do the same with any comments from � Conservation. Thanks, Amy Amy L.von Hone, R.S., C.H.O. Assistant Health Director ! Yarmouth Health Department i From: David Hendrick [mailto:davidhendrick4lCa�gmail.com] � Sent: Wednesday, November 04, 2015 10:08 AM To: vonHone, Amy Subject: 28 Charles St. i � Amy, Any update on 28 Charles St. Thanks � David Hendrick ` I ( i I I ( i i i , � � i I UTILITY POLE TEST HOLE EL=19.1' UTILITY POLE LAMP POST Ld \ \ (f� PAVED`\ DRIVE `\ 1 I \ - , EXISTI E' CTRICALIIFROM N H SE (LOdATE) X I x GARAGE i I I I EXISTINd CESSOOOLSI� i ( X (PUMP AND FIL( (nolle 10)! IN W W i 1�1' �— ® ptiI WATER GATE CE 2T ® Kel PROP. 2,500 GALLON 2—COMPARTMENT SEPTIC TANK (1,50OG/1,000G) TOP OF COASTAL BANK AT EL. 9.0 BENCHMARK CORNER �5 BRICK STEP EL=18.5' SOUTH YARMOUTH ,��`� HEALTH DEPT. ` W SCALE: 1"=30* LOCUS 28 CHARLES sr. -7 kF<< LOCUS INFORMATION 2 z £Y R • TITLE REF: BK 11681 PG 294 cG^ PARCEL ID: MAP 070 PAR. 114 ���OFMAss9c LOT SIZE: 1.10 ACRES �o�' JOHN Z. FLOOD ZONE: "AE" EL. 11.0 DEMAREST,JR. 1�7 COMM. PANEL: 25001 CO591 J No. 36859 ` o 9 ROUTE 28 DATED: 07/16/14 nEss`0 LOCUS MAP LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE TEST PIT tf)-v,� SEPTIC SYSTEM of MAs REPAIR PLAN ��P� SAcy LOCATED AT: D `E V 28 CHARL STREET by SOUTH YARM UTH, A cisr° PREPARED F N I TAR�1`� J E N N E Y OCTOBER 16, 2015 , RSH EDG OF�� SALTM RSH �( ED11 OF "--- SALTM H \, DELINEATI COND, TED Y: BR H LL ;I MEYE & SONS INC. P.O. Box 981 E. NDWICH, MA 02537 PH: (508) 360-3311 FAX: (774) 413-9468 meyerandsonstitle5@gmail.com www.meyerandsons.com SHEET 1 OF 2 J#1747 � r t / A EXISTING' I' ' DWELLING ' T0�#28 18.7'f Ai !oil i, WALL 1 STONE EXISTING CESSPO TO BE PUMPED AND HAND FILLED r r r BENCHMARK CORNER �5 BRICK STEP EL=18.5' SOUTH YARMOUTH ,��`� HEALTH DEPT. ` W SCALE: 1"=30* LOCUS 28 CHARLES sr. -7 kF<< LOCUS INFORMATION 2 z £Y R • TITLE REF: BK 11681 PG 294 cG^ PARCEL ID: MAP 070 PAR. 114 ���OFMAss9c LOT SIZE: 1.10 ACRES �o�' JOHN Z. FLOOD ZONE: "AE" EL. 11.0 DEMAREST,JR. 1�7 COMM. PANEL: 25001 CO591 J No. 36859 ` o 9 ROUTE 28 DATED: 07/16/14 nEss`0 LOCUS MAP LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE TEST PIT tf)-v,� SEPTIC SYSTEM of MAs REPAIR PLAN ��P� SAcy LOCATED AT: D `E V 28 CHARL STREET by SOUTH YARM UTH, A cisr° PREPARED F N I TAR�1`� J E N N E Y OCTOBER 16, 2015 , RSH EDG OF�� SALTM RSH �( ED11 OF "--- SALTM H \, DELINEATI COND, TED Y: BR H LL ;I MEYE & SONS INC. P.O. Box 981 E. NDWICH, MA 02537 PH: (508) 360-3311 FAX: (774) 413-9468 meyerandsonstitle5@gmail.com www.meyerandsons.com SHEET 1 OF 2 J#1747 It M NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH SEPTIC TANK GRADE SHALL NOT BE < EL:16.10 FOR A DISTANCE T.O.F. EL.=18.701 INSTALL RISERS & COVERS OVER INLET & PROPOSED D -BOX 15' AROUND THE PERIMETER OF THE S.A.S. OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & COVER PROPOSED .A . INSTALL LOCKING COVERS IF AT FINISH GRADE SET TO 6" OF GRADE INSTALL RISER W/ METAL RINGS AND COVERS TO GRADE IN PAVEMENT F.G. EL.=17.50± /-F.G. EL.=18.50± i-F.G. EL: 19.0± 9" MIN COVERtfl ' L 10' S= 36" MAX COV1% (MIN.) EL.=16.85±0 S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC INV.=15.82 /Fl= ­FAM UHII 14 GAS BAFFLE -J I I GAS BAFFLE INV.=15.5-7 INV.= 15.47 PROP. 2 -COMP 2.500 GALLON SEPTIC TANK EWER OUTLET A EL. 16.06 B EL. 16.62 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED 4) PLUMBING TO BE RE-ROUTED TO OUTLET 6 SHOWN. BOTTOM OF OUTLET PIPE TO BE 32" BELOW TOP OF FND. INJECTOR PUMP TO BE INSTALLED TO PUMP UP BASEMENT FLOW, 2 OF 5 BEDROOMS, (PLMBG PERMIT REQ'D) 5) PLUMBING FOR OUTLET n TO BE RAISED TO 24" BELOW T.1 DESIGN CRITERIA L = 10'(MAX) 0 S=1% (MIN.) 4"SCH40 PVC NV. =15.30 F.G. EL: 19.0(MAX.) 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC i INV. ELEV.= 15.1 TOP CONC. ELEV.= 16.10 INV. ELEV.= 15.10 _ BOTTOM EL.= 13.1 SEPARATION 5.00 FT. BOTTOM OF TESTHOLE EL: 8.1 SEPTIC SYSTEM PROFILE T.S. NUMBER OF BEDROOMS: EXISTING 5 BR TOTAL DESIGN FLOW, (2 BRS W/INJECTOR PUMP) SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 5 BR DESIGN FLOW: 550 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 550 gpd x 200% = 1,100 gpd, EJECTOR PUMP 2 OF 5 BEDROOMS, 40% FLOW USE NEW 2,500 GALLON (1,500/1,000) SEPTIC TANK, MEETS 310CMR15.229(2) LEACHING AREA REQUIRED: (550)/0.74 = 743.24 S.F. USE FOUR (4) 500 GALLON H2O PRECAST LEACH CHAMBERS W/ 4' STONE ON ALL SIDES: 42' L x 13' W x 2' D BOTTOM AREA: 42 x 13 = 546 SF SIDE AREA: (42 + 13) X 2 X 2 = 220 SF TOTAL SQUARE FEET PROVIDED = 766 vs. 743.24 REQ'D DESIGN FLOW PROVIDED: 0.74(766 S.F.) = 566 G.P.D. vs. 550 G.P.D. req'd 3/4" - 1 -1/2 - DOUBLE WASHED STONE BREAKOUT ELEV.= 16.10 4 _ E 5 FT. _4' EFFECTIVE WIDTH ='13' (500 GALLON H2O LEACH CHAMBER) SOIL LOGS DATE: SEPTEMBER 23, 2015 SOIL EVALUATOR: DARREN M. MEYER, RS, CSE WITNESS: AMY VONHONE, YARMOUTH HEALTH GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS NOTED BELOW: VARIANCE FROM 310CMR15.229(2): TO ALLOW EJECTOR PUMP TO PUMP 40% OF DAILY FLOW VS. 25%, FULL COMPLIANCE WITH 310CMR15.229 PRO 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON NAVD DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWELLING IS SERVICED BY MUNICIPAL WATER. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE L ON OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. (STING CESSPOOLS TO BE PUMPED, CRUSHED AND F14E TITLE 5. 10.�48 HOUR NOTICE FOR ENGINEER CERTIFICATION � 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM pi/, RPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. Elev. I TP - 1 Depth 19.10 A LOAMY SAND " OF 18.18 1 10" B LOAMY SAND o ARREN M. 15.77C1 1OYR 6/8 40" E 1 MEDIUMCEO SAND MASITAR1P� PERC TEST 12.28 2.5Y 6/4 1 l� PROPOSED SEPTIC SYSTEM UPGRADE PLAN 8.10 132" PERC RATE <2 MIN/IN. ('Cl" HORIZON) NO GROUNDWATER OBSERVED I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify than I have passed the Soil Eval. Exam in October, 1999. 28 CHARLES STREET, SOUTH YARMOUTH, MA Prepared for: Jenney System Design and Site Plan by: SCALEDRAWN DATE MEYER &SONS, INC. N.T.S. DMM 10/16/15 PO BOX 981 EASTSANDWICH,MA02537 REV DATE CHECKED SHEET NO. 508-362-2922 DMM 2 of 2