Loading...
HomeMy WebLinkAboutReview Checklist � /z -�--�� ,��� � TOWN AF YARMOUTH J� � SEWAGE PLAN REVIEW CAECKLIST ��k,'� � ���� � . Location: A.M. � � LotJC� Zone of Contribution: In�t_ Acrea.ge_��,��Y�' ; • �� Commercial: Residential:_ % ; Street: � Village: � Floor Plan: #Bedrooms: ��" Owner: � /OS//1 ,��1°�I�I Installer: Address: Phone: - Phone: �D�- ?�'�`�' 7��i�- ��' - �l� ��� � � ���� Builder: Engineer: Address: Phone: -_�- Phone: -�J� � -�"---� '1 � N/A YES NO l.Required#of copies received 2.Date of soils exam and ercolation test not older than 2 ears 3.4-5 ft of naturall occurrin ervious material,above water table 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from s tic components Var.: (�/� 6.Benchmark indica.ted and shown-NGVD if near wetlands 7. Se tic tank minimum 10 ft from foundation, deck Var.: 8.Lea.ching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinking welU25 ft irrigation well Vax.: 11.Ta.nk/leaching minimum 10 ft from rop line Var.: �--� '' 12. S stem meets all other setback re uirements Var.: l_./ 13.Uses adjustment for maximum hi groundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: L� 15. System not in top or subsoil(A,B horizons)or 5'removal �-�� 16.Pro osed contours are suita.ble -L-� 17. S stem meets slo e r uirements-min. 1/8", I/4" referred Z._--^ 18. System meets brea.kout r uirements PVC liner: Wa1L• 19. S ecified tee sizes are ro er, gas baffle on outlet tee `--� , 20. Sewage is under 10,000 d for arcel '�� , 21.No arbage disposal �� 22. S stem ade uatel sized for its intended use " 23.Minimum 6"stone or com acted below tank and dbox 24.Manhole covers within 6"of grade, um chamber cover to ade 25.Inspection ort on lastic chambers/leach field 26.Electrical ermit for um chamber/S arate meter for du lexes - 27.Pump system-2" line,wee hole,check valve,tee in dbox,pum size c----' 28. S tic tank/ ump chamber to be factory wat roofed � 29.Vent rovided if leaching below 3 feet,under drivewa / arkin �� 30. Buoyancy calcula.tions for tank/ ump chamber 31.E ' eer to ins ect and c ' soils: wall: commercial: �-' _ 32.Engineer/Registered Sanitarian and Land Surveyor stam s/signature 33.H-20 loading is sub'ect to vehicular traffic, groundwater 34.Title V A lication and ermit fee, insta.11er si ture 35.Founda.tion footing min.2 feet above adjusted ound water for new house ��� 36.Deed Restriction r ired max. #bedrooms: max.flow: d -�--- 37.Check area.lots for oundwater/Label oundwater in Assessor's Ma Plan reviewed by: � �o3ro3